Produkte Products Seite 1 von 10 Page 1 of 10 TÜV Rheinland Energy GmbH Am Grauen Stein 51105 Köln Germany Tel.: +49 221 806-5222 Fax: +49 221 806-1350 Mail: [email protected] Web: www.tuv.com/solarenergy Prüfbericht-Nr.: Test Report No.: 21290449.002 Auftrags-Nr.: Order No.: 21243643 Kunden-Referenz-Nr.: Client Reference No.: 3201853 Auftragsdatum: Order date: 15 May 2018 Auftraggeber: Client: Philadelphia Solar, Al Qastal Industrial Area 2, Airfreight Road, 11814 Amman, Jordan Prüfgegenstand: Test item: Photovoltaic (PV) modules Bezeichnung / Typ-Nr.: Identification / Type No.: see sections 1 "Product details" and "List of test samples" Auftrags-Inhalt: Order content: Determination of PV module performance characteristics according to the Guidelines for California's Solar Electric Incentive programs (CEC) Prüfgrundlage: Test specification: Photovoltaic (PV) modules Determination of PV module performance characteristics according to the Guidelines for California's Solar Electric Incentive programs 6 th Ed., 11.2016 and IEC 61215:2005 / IEC 61646:2008 - CEC-300-2016-008-CMF Wareneingangsdatum: Date of receipt: 06 June 2018 Prüfmuster-Nr.: Test sample No.: see others Prüfzeitraum: Testing period: 06 June 2018 - 25 September 2018 Ort der Prüfung: Place of testing: Cologne Prüflaboratorium: Testing laboratory: Solar Energy Assessment Center Prüfergebnis*: Test result*: Siehe Sonstiges / See Other geprüft von / tested by: 14 November 2018 N. Schwarze,Project manager kontrolliert von / reviewed by: 14 November 2018 L.Jakisch,Business Field manager Datum Date Name / Stellung Name / Position Unterschrift Signature Datum Date Name / Stellung Name / Position Unterschrift Signature Sonstiges / Other: All required test results for California Solar Electric Incentive programme are listed on the following pages of this report. Test sample No.: HV2018001861, HV2018001862, HV2018002027, HV2018002028 This report is a revision of report 21290449.001. Please compare the "history of reporting" attached. Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark.

21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Embed Size (px)

Citation preview

Page 1: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

Seite 1 von 10 Page 1 of 10

TÜV Rheinland Energy GmbH Am Grauen Stein 51105 Köln Germany Tel.: +49 221 806-5222 Fax: +49 221 806-1350 Mail: [email protected] Web: www.tuv.com/solarenergy

Prüfbericht-Nr.: Test Report No.:

21290449.002 Auftrags-Nr.: Order No.:

21243643

Kunden-Referenz-Nr.: Client Reference No.:

3201853 Auftragsdatum: Order date:

15 May 2018

Auftraggeber: Client:

Philadelphia Solar, Al Qastal Industrial Area 2, Airfreight Road, 11814 Amman, Jordan

Prüfgegenstand: Test item:

Photovoltaic (PV) modules

Bezeichnung / Typ-Nr.: Identification / Type No.:

see sections 1 "Product details" and "List of test samples"

Auftrags-Inhalt: Order content:

Determination of PV module performance characteristics according to the Guidelines for California's Solar Electric Incentive programs (CEC)

Prüfgrundlage: Test specification:

Photovoltaic (PV) modules

Determination of PV module performance characteristics according to the Guidelines for California's Solar Electric Incentive programs 6th Ed., 11.2016 and IEC 61215:2005 / IEC 61646:2008 - CEC-300-2016-008-CMF

Wareneingangsdatum: Date of receipt:

06 June 2018

Prüfmuster-Nr.: Test sample No.:

see others

Prüfzeitraum: Testing period:

06 June 2018 - 25 September 2018

Ort der Prüfung: Place of testing:

Cologne

Prüflaboratorium: Testing laboratory:

Solar Energy Assessment Center

Prüfergebnis*: Test result*:

Siehe Sonstiges / See Other

geprüft von / tested by:

14 November 2018 N. Schwarze,Project manager

kontrolliert von / reviewed by:

14 November 2018 L.Jakisch,Business Field manager

Datum Date

Name / Stellung Name / Position

Unterschrift Signature

Datum Date

Name / Stellung Name / Position

Unterschrift Signature

Sonstiges / Other: All required test results for California Solar Electric Incentive programme are listed on the following pages of this report. Test sample No.: HV2018001861, HV2018001862, HV2018002027, HV2018002028 This report is a revision of report 21290449.001. Please compare the "history of reporting" attached.

Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery:

Prüfmuster vollständig und unbeschädigt Test item complete and undamaged

* Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft

P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet

Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor

P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested

Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht

auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens.

This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark.

Page 2: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

Prüfbericht-Nr.: 21290449.002 Test Report No.:

Seite 2 von 10 Page 2 of 10

Liste der verwendeten Prüfmittel List of used test equipment

Rev.:01

Prüfmittel Test equipment

Prüfmittel-Nr. / ID-Nr. Equipment No. / ID-No.

Nächste Kalibrierung Next calibration

All equipment used for tests, including equipment for subsidiary measurements having a significant effect on the accuracy or validity of the result of the test is calibrated before being put into service. The laboratory has an established programme and procedure for the calibration of its equipment according to EN ISO/IEC 17025 (Reg. no.: D-PL-11120-01-00).

Page 3: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

Prüfbericht-Nr.: 21290449.002 Test Report No.:

Seite 3 von 10 Page 3 of 10

Produktbeschreibung Product description

Rev.:01

1 Produktdetails Product details

For the tested modules, please see “List of test samples” on page 4. The modules are currently under IEC 61215:2016/61730:2016 and UL 61730 qualification. In this context, tolerances, current and voltage values as well as some of the power classes needed to be adapted following Gate No. 1 (7.2.1) of IEC 61215-1:2016. In addition, type designations were adapted slightly. If all qualification tests are passed, the updated power classes should be as follows:

with 6“ poly cells PS-P72-xxxW (AQABA) (xxx= 320 – 330 in steps of 5) PS-P60-xxxW (MAFRAQ) (xxx= 265 – 275 in steps of 5)* with 6” mono cells PS-M72-xxxW (AMMAN) (xxx= 360 – 365 in steps of 5) PS-M60-xxxW (JARASH) (xxx= 295 – 305 in steps of 5)

xxx represent output power in Wp

* Power classes of PS-P60-xxxW (MAFRAQ) shall now be increased by 5Wp per power class. E.g. PS P60-265W (MAFRAQ) is planned to be labelled with PS-P60-270W (MAFRAQ). Please see the photo appendix for the type labels of the test samples as well as the current versions of the updated test labels.

2 Verwendete Materialien Used materials

see Constructional Data Form (CDF) No. 21290450.001 (still under preparation, as IEC 61215:2016 / 61730:2016 and UL61730 project is still ongoing).

3 Adresse(n) der Fertigungsstätte(n) Address(es) of the manufacturing site(s)

Philadelphia Solar, Al Qastal Industrial Area 2, Airfreight Road, 11814 Amman, Jordan, Inspection report no.: 21183161.006 (October 2017) Next factory inspection is scheduled for 24th of October 2018.

4 Zusammenfassung der Prüfergebnisse Summary of test results

According to the inquiry of the customer the performance characteristics of 4 PV module types were determined according to the Guidelines for California's Solar Electric Incentive programs 6th Ed., 11.2016 and IEC 61215:2005 / IEC 61646:2008 - CEC-300-2016-008-CMF.

This test report includes an appendix “Zusatzdokumentation/Additional Documentation” including the history of reporting and certification and an appendix “Foto-Dokumentation/Photo Documentation”.

Page 4: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

Prüfbericht-Nr.: 21290449.002 Test Report No.:

Seite 4 von 10 Page 4 of 10

Absatz Photovoltaic (PV) modules Messergebnisse - Bemerkungen Bewertung

Evaluation Clause Anforderungen - Prüfungen / Requirements - Tests Measuring results - Remarks Evaluation

Rev.:01

— Test specification

Crystalline silicon terrestrial photovoltaic (PV) modules – Design qualification and type approval

IEC 61215:2005 —

— Marking

Name, monogram or symbol of manufacturer

— P

Type or model number — P

Serial number — P

Polarity of terminals or leads — P

Maximum system voltage — P

Date and place of manufacture* — P

Remarks:

*Serial number on type label. See photos in appendix.

According to Philadelphia Solar, production order date is prefix of serial number and serial number is connected to the flasher data.

— List of test samples

Sample No. Sample S/N Remarks/constructional characteristics

(e.g. cell, backsheet, frame type)

HV2018001861 PS080518429702

PS P72-325W (Aqaba)

(Type name should be changed to PS-P72-325W (AQABA) )

HV2018001862 PS250418420452

PS M72-365W (Amman)

(Type Name should be changed to PS-M72-365W (AMMAN) )

HV2018002027 PS260618436715

PS M60-300W (JARASH)

(Type Name should be changed to PS-M60-300W (JARASH))

HV2018002028 PS260618436702

PS P60-265W (MAFRAQ)

(Power class with new tolerances should be raised to 270W. Type Name should be changed to PS-P60-270W

(MAFRAQ))

Remarks: Module types are currently in IEC 61215/61730 (2016) – qualification testing. Type designations (additionally power classes of PS-P60-xxxW (MAFRAQ) were adapted) were adapted after Gate No. 1 of IEC 61215-1:2016. For further details, please also compare chapter 1 “product details”. Please see the photo appendix for the type labels of the test samples as well as the current versions of the updated test labels.

Page 5: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

Prüfbericht-Nr.: 21290449.002 Test Report No.:

Seite 5 von 10 Page 5 of 10

Absatz Photovoltaic (PV) modules Messergebnisse - Bemerkungen Bewertung

Evaluation Clause Anforderungen - Prüfungen / Requirements - Tests Measuring results - Remarks Evaluation

Rev.:01

— IEC/EN 61215 - Design qualification and type approval

10 Preconditioning (min. 5.5 kWh) P

10.1 Visual inspection See table 10.1 P

10.2 Maximum power determination —

10.4 Measurement of temperature coefficients See table 10.4 —

10.6 Performance at STC See table 10.6.1 —

10.5 Measurement of Nominal Operating Cell Temperature (NOCT)

See table 10.5 —

10.6 Performance at NOCT See table 10.6.2 —

10.7 Performance at low irradiance See table 10.7 —

10.1 Visual inspection (Initial)

Sample No. Nature and position of initial findings —

HV2018001861 — P

HV2018001862 — P

HV2018002027 junction: Junction box gluing unclean, frame: Gluing unclean P

HV2018002028 junction: Junction box gluing unclean, frame: Gluing unclean P

Supplementary information: -

Page 6: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

Prüfbericht-Nr.: 21290449.002 Test Report No.:

Seite 6 von 10 Page 6 of 10

Absatz Photovoltaic (PV) modules Messergebnisse - Bemerkungen Bewertung

Evaluation Clause Anforderungen - Prüfungen / Requirements - Tests Measuring results - Remarks Evaluation

Rev.:01

10.4 Measurement of temperature coefficients

Ambient air temperature °C 25 ± 2

Irradiance W/m² 1000 ± 50

Module temperature °C high/low 68.2 / 24.4

Sample No. Coefficient Calculated value

HV2018001861

ISC %/°C 0.038

Impp %/°C -0.017*

Uoc %/°C -0.313

Umpp %/°C -0.405

%/°C -0.419

Supplementary information: Temperature coefficients were measured under a flashlight solar simulator.

* Measurement results show a strong and not clear linear variation of Impp over temperature. This is attributed to the fact that the value of Pmpp can remain constant even though its operating point on the IV curve changes slightly. Therefore measurements of temperature coefficient of current at MPP always have high uncertainties. Basing yield predictions on these values is not suggested.

10.4 Measurement of temperature coefficients

Ambient air temperature °C 25 ± 2

Irradiance W/m² 1000 ± 50

Module temperature °C high/low 75 / 26.5

Sample No. Coefficient Calculated value

HV2018001862

ISC %/°C 0.033

Impp %/°C -0.030*

Uoc %/°C -0.291

Umpp %/°C -0.370

%/°C -0.393

Supplementary information: Temperature coefficients were measured under a flashlight solar simulator.

* Measurement results show a strong and not clear linear variation of Impp over temperature. This is attributed to the fact that the value of Pmpp can remain constant even though its operating point on the IV curve changes slightly. Therefore measurements of temperature coefficient of current at MPP always have high uncertainties. Basing yield predictions on these values is not suggested.

Page 7: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

Prüfbericht-Nr.: 21290449.002 Test Report No.:

Seite 7 von 10 Page 7 of 10

Absatz Photovoltaic (PV) modules Messergebnisse - Bemerkungen Bewertung

Evaluation Clause Anforderungen - Prüfungen / Requirements - Tests Measuring results - Remarks Evaluation

Rev.:01

10.5 Measurement of Nominal Operating Cell Temperature (NOCT)

Wind velocity m/s high/low* 1.75 / 0.25

Ambient temperature °C high/low* 35.00 / 18.74

Irradiance W/m² high/low* 1124.82 / 400.77

Module temperature °C high/low* 70.62 / 36.15

Number of NOCT Value 1 2 3 4

Wind velocity m/s (average) 0.94 0.95 1.01 0.92

NOCT correction factor °C 2 2 2 0

Calculated NOCT °C 52.35 54.99 51.03 49.58

Number of NOCT Value 5 6 7 8

Wind velocity m/s (average) 1.08 0.89 0.96 1

NOCT correction factor °C 1 0 1 1

Calculated NOCT °C 50.48 51.45 56.04 51.73

Sample No. Average NOCT °C

HV2018001861 52.2

Supplementary information: Primary method was used.

Number of total NOCT values: 8.

*Highest/lowest values of all 8 NOCT values.

Page 8: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

Prüfbericht-Nr.: 21290449.002 Test Report No.:

Seite 8 von 10 Page 8 of 10

Absatz Photovoltaic (PV) modules Messergebnisse - Bemerkungen Bewertung

Evaluation Clause Anforderungen - Prüfungen / Requirements - Tests Measuring results - Remarks Evaluation

Rev.:01

10.5 Measurement of Nominal Operating Cell Temperature (NOCT)

Wind velocity m/s high/low 1.75 / 0.25

Ambient temperature °C high/low 35.00 / 18.74

Irradiance W/m² high/low 1124.82 / 400.77

Module temperature °C high/low 69.79 / 34.8

Number of NOCT Value 1 2 3

Wind velocity m/s (average) 0.94 0.95 1.01

NOCT correction factor °C 2 2 2

Calculated NOCT °C 51.02 52.35 50.40

Number of NOCT Value 4 5

Wind velocity m/s (average) 0.98 0.92

NOCT correction factor °C 1 0

Calculated NOCT °C 46.85 48.68

Sample No. Average NOCT °C

HV2018001862 49.9

Supplementary information: Primary method was used.

Number of total NOCT values: 5.

*Highest/lowest values of all 5 NOCT values.

Page 9: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

Prüfbericht-Nr.: 21290449.002 Test Report No.:

Seite 9 von 10 Page 9 of 10

Absatz Photovoltaic (PV) modules Messergebnisse - Bemerkungen Bewertung

Evaluation Clause Anforderungen - Prüfungen / Requirements - Tests Measuring results - Remarks Evaluation

Rev.:01

10.6.1 Performance at STC

Test method indoor outdoor

Ambient temperature °C 25 ± 2

Irradiance W/m² 1000 ± 50 corrected to 1000

Module temperature °C 25 ± 2 corrected to 25

Sample No. Pmax W Vmpp V Impp A Voc V Isc A FF %

HV2018001861 319.3 37.26 8.57 45.73 9.07 77.0

HV2018001862 351.6 38.76 9.07 47.54 9.52 77.7

HV2018002027 291.8 32.03 9.11 39.72 9.62 76.4

HV2018002028 265.1 31.05 8.54 38.05 9.04 77.1

Supplementary information: -

10.6.2 Performance at NOCT

Test method indoor outdoor

Ambient temperature °C 25 ± 2

Irradiance W/m² 800

Module temperature °C NOCT:

HV2018001861, HV2018002028: 52.2°C

HV2018001862, HV2018002027: 49.9°C

Sample No. Pmax W Vmpp V Impp A Voc V Isc A FF %

HV2018001861 225.0 33.05 6.81 41.35 7.29 74.7

HV2018001862 256.5 35.33 7.26 43.83 7.72 75.8

HV2018002027 211.6 29.13 7.26 36.54 7.75 74.7

HV2018002028 189.8 27.81 6.82 34.52 7.29 75.4

Supplementary information: -

Page 10: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

Prüfbericht-Nr.: 21290449.002 Test Report No.:

Seite 10 von 10 Page 10 of 10

Absatz Photovoltaic (PV) modules Messergebnisse - Bemerkungen Bewertung

Evaluation Clause Anforderungen - Prüfungen / Requirements - Tests Measuring results - Remarks Evaluation

Rev.:01

10.7 Performance at low irradiance

Test method indoor outdoor

Ambient temperature °C 25 ± 2

Irradiance W/m² 200 ± 20 corrected to 200

Module temperature °C 25 ± 2 corrected to 25

Sample No. Pmax W Vmpp V Impp A Voc V Isc A FF %

HV2018001861 55.0 35.73 1.54 41.86 1.63 80.5

HV2018001862 63.9 38.13 1.67 44.16 1.76 82.1

HV2018002027 58.0 31.44 1.85 36.73 1.94 81.6

HV2018002028 50.8 29.97 1.70 35.30 1.80 80.1

Supplementary information: -

Page 11: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 1 von 5 Page 1 of 5

ZUSATZ-DOKUMENTATION

ADDITIONAL DOCUMENTATION

Appendix: History of reporting and certification

No. Project no. Date of issue Result Remarks

001 21243643 17/10/2018 — —

002 21243643 14/11/2018 —

- Chapter 1 “Product details: o Correction of module type

names and update of module power classes

o Minor changes in wording + some supplementary information (e.g. regarding adaptation of some parameters like power classes, tolerances, current, voltage, etc.)

- Chapter “ List of test samples” o Adding of additional information

regarding change of type names - Photo Appendix: Adding of lay-out of

new, updated labels

Page 12: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 2 von 5 Page 2 of 5

ZUSATZ-DOKUMENTATION

ADDITIONAL DOCUMENTATION

Fig 1: HV201801861- P@STC, P@NOCT

Fig 2: HV2018001861 – P@LI

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

0 10 20 30 40 50

Cu

rre

nt

in [A

]

Voltage in [V]

Page 13: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 3 von 5 Page 3 of 5

ZUSATZ-DOKUMENTATION

ADDITIONAL DOCUMENTATION

Fig 3: HV201801862 – P@STC, P@NOCT

Fig 4: HV2018001862 – P@LI

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

0 10 20 30 40 50

Cu

rre

nt

in [A

]

Voltage in [V]

Page 14: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 4 von 5 Page 4 of 5

ZUSATZ-DOKUMENTATION

ADDITIONAL DOCUMENTATION

Fig 5: HV2018002027 – P@STC, P@NOCT

Fig 6: HV2018002027 – P@LI

0.0

0.5

1.0

1.5

2.0

2.5

0 10 20 30 40 50

Cu

rre

nt

in [A

]

Voltage in [V]

Page 15: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 5 von 5 Page 5 of 5

ZUSATZ-DOKUMENTATION

ADDITIONAL DOCUMENTATION

Fig 7: HV2018002028 – P@STC, P@NOCT

Fig 8: HV2018002028 – P@LI

Page 16: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 1 von 8 Page 1 of 8

FOTO-DOKUMENTATION

PHOTO-DOCUMENTATION

PS M60-300W (JARASH) PS M60-300W (JARASH)

Label of test sample: PS M60-300W (JARASH) Updated label: PS M60-300W (JARASH)

PS M60-300W (JARASH) PS M60-300W (JARASH)

Page 17: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 2 von 8 Page 2 of 8

FOTO-DOKUMENTATION

PHOTO-DOCUMENTATION

PS M60-300W (JARASH)

Page 18: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 3 von 8 Page 3 of 8

FOTO-DOKUMENTATION

PHOTO-DOCUMENTATION

PS P60-265W (MAFRAQ) PS P60-265W (MAFRAQ)

Label of test sample: PS P60-265W (MAFRAQ) Updated label PS-P60-270W (MAFRAQ)

PS P60-265W (MAFRAQ) PS P60-265W (MAFRAQ)

Page 19: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 4 von 8 Page 4 of 8

FOTO-DOKUMENTATION

PHOTO-DOCUMENTATION

PS P60-265W (MAFRAQ) PS P60-265W (MAFRAQ)

Page 20: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 5 von 8 Page 5 of 8

FOTO-DOKUMENTATION

PHOTO-DOCUMENTATION

PS M72-xxxW (Amman) PS M72-xxxW (Amman)

Label of test sample: PS M72-365W (Amman) Updated label: PS-M72-365W (AMMAN)

PS M72-365W (Amman)

Page 21: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 6 von 8 Page 6 of 8

FOTO-DOKUMENTATION

PHOTO-DOCUMENTATION

PS M72-365W (Amman)

Page 22: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 7 von 8 Page 7 of 8

FOTO-DOKUMENTATION

PHOTO-DOCUMENTATION

PS P72-325W (Aqaba) PS P72-325W (Aqaba)

Label of test sample: PS P72-325W (Aqaba) Updated label: PS-P72-325W (AQABA)

PS P72-325W (Aqaba) PS P72-325W (Aqaba)

Page 23: 21290449.002 Auftrags-Nr.: 3643 - philadelphia-solar.com · Produkte Products Prüfbericht-Nr.: 21290449.002 Test Report No.: Seite 2 von 10 Page 2 of 10 Liste der verwendeten Prüfmittel

Produkte Products

ANLAGE zum Prüfbericht-Nr.: 21290449.002 APPENDIX to Test Report No.:

Seite 8 von 8 Page 8 of 8

FOTO-DOKUMENTATION

PHOTO-DOCUMENTATION

PS P72-325W (Aqaba)