    2. Allgemeine Beschreibung

    Operating Manual NAV 1.02

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    All rights reserved for modifi cations to the technology and design.

    General instructions on operating the heat pump.

    Important instructions on assembling and operating the heat pump. It is imperative that these are observed.

    General instructions on assembling the heat pump.

    Space for customer servicetelephone number

    Contents

    Co

    nte

    nts

    OPERATING INSTRUCTIONS 3

    1. DESCRIPTION 51.1. General information 51.2. Navigator Control for HGL Technology 61.3. Structure of the Navigator Control 6

    2. OPERATION 72.1. Operation using the Control Unit 72.2. Displays in the Main Menu 72.3. Displays in the Status Bar 8

    3. OPERATING MODES 103.1. Operating Modes via the Main Menu 10

    4. TEMPERATURE SETTINGS 144.1. Temperature Settings via the Main Menu 14

    5. TIME SETTINGS 205.1. Time Settings via the Main Menu 20

    6.MY IDM SERVICE PLATFORM 256.1 Integeration of the heat pump in the internet 256.2 Configuration of the heat pump 266.3 Registration 296.4 Smart phone based control 32

    7. INFORMATION 377.1. Information via the Main Menu 37

    8. FAULTS 408.1. Error Display in the Main Menu 40

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 3

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    Op

    era

    tin

    g I

    nst

    ruct

    ion

    s

    Operating Instructions

    Terra heat pumps may only be installed by competent specialist staff and commissioned and serviced by a customer service company trained to do so by IDM-Energiesysteme GmbH.

    Service and repair work must also be undertaken by a company customer service company trained to do so by IDM- Energisysteme GmbH.

    Switching the system on and off:

    Including in emergencies, the main switch at the top of the heat pump, or in the case of CL heat pumps by using the main switch on the independent control cabinet, is used to switch the system on and off.

    Safety of operation can no longer be guaranteed if the equipment

    - Has visible damage - No longer operates - Repetitive error warnings are displayed.

    Should this be the case, the equipment must be shut down, secured against unintentional operation and customer service informed.

    In the event of an error, the heat pump is automatically switched off. The Navigator Control display issues an error warning. (see chapter 7).

    Refrigerant:

    Refrigerant used: R407C R134a R410A

    In the event of any required repairs, no other refriger-ant should be used.

    Refrigerant fi lling weight: ________ kgMaximum operating pressure: 31/24/42 bar

    Safety instructions for the refrigerant:

    Rapid evaporation of the refrigerant can cause frost damage.

    Refrigerant vapours are heavier than air and, due to atmospheric oxygen deprivation, can lead to suffoca-tion. Therefore, in the event of an incident, it must be ensured that the installation room is well ventilated.

    First aid measures:

    General instructions: in the case of unconsciousness, place the person on their side and seek medical as-sistance. Never administer anything into the mouth of an unconscious person. Use artifi cial respiration in the event of uneven breathing or respiratory standstill. Should diffi culties persist, consult a doctor.

    Inhalation: Go out in the fresh air. Keep the affected person in a warm and quiet place. Artifi cial respiration and/or oxygen may be required. Contact with the skin:Wash off with warm water. Immediately remove soiled, impregnated clothing.Contact with the eyes:Immediately rinse with lots of water, including under the eyelids. Consult a doctor.

    If any of the housing parts are removed this can lead to the risk of injury from an electric shock and hot surfaces.

    TERRA CL main switch

    TERRA SW main switch

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    1. Description

    Operating Manual NAV 1.04

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    Op

    era

    ting

    Instru

    ction

    s

    Operating instructions

    danger of crushing!

    hot components e.g. pipes, plate heat exchanger

    danger of injury (sharp edged) cold components

    hot surfaces

    high pressure!

    Screw tight the fixing togglefor the cover panels with a hexagon wrench.

    Attention! High Voltage Turn main switch off bevore opening

    the housing!

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 5

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    De

    scri

    pti

    on

    1. Description

    1.1. General information

    By purchasing this system you have acquired a modern and effi cient heating system. Ongoing qual-ity controls and improvements as well as functional checks at the plant guarantee you technically perfect equipment. Please read through this documentation carefully. The instructions contain important indica-tions regarding the safe and economic operation of the system.

    1.1.1. Sound emission

    TERRA heat pumps are very quiet in operation thanks to their design. It is however important that the site of the heater is situated as far as possible from noise-sensitive living areas. A noise-insulating door should be fi tted door.

    1.1.2. Construct ion dr ying/screed heat ing

    The heat pump is not designed for the increased heat requirements when drying out construction work or heating plaster or screed. This must be covered by equipment to be provided by the customer if required.

    1.1.3. Ser vic ing and maintenance

    Regular maintenance as well as checking and servic-ing of all system components guarantee its safe and economical operation in the long term. To achieve this, we recommend a maintenance contract with the relevant IDM customer service company.

    1.1.4. Cleaning

    If necessary, the TERRA heat pump can be cleaned with a damp cloth. The use of cleaning agents is not recommended.

    A cleaning via a high pressure cleaner is not permit-ted!

    1.1.5. Working on the equipment

    Assembly, initial commissioning, inspection, mainte-nance and repairs must only be performed by author-ised specialist staff.

    Heat pumps may only be installed by competent spe-cialist staff and commissioned by a customer service company trained to do so by IDM-Energiesysteme GmbH. When working on the heat pump, it must be deactivated and secured against reactivation. When working on the heat pump, all safety instructions in the relevant documentation, stickers on the heat pump itself and all other applicable safety regulations must be observed.

    1.1.6. In the event of hazards

    Immediately disconnect the system from the mains, e.g. using a separate fuse or a main switch. In the case of fi re use suitable fi re extinguishers.

    Please strictly observe the safety instruc-tions in this regard to avoid hazards and injury to people and material damage.

    According to EU- standard 842/2006, an annual check for heat pumps with more than 3kg refrigerant is prescribed.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    1. Description

    Operating Manual NAV 1.06

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    Description

    De

    scriptio

    n

    1.1.7. Refr igerant leak

    The heat pump is fi lled with a non-toxic and non-fl ammable refrigerant. If there is damage however, refrigerant could leak and lead to oxygen deprivation. Moreover, open fi re can also lead to harmful de-composition products. As such, upon the immediate detection of refrigerant leak (smell) leave the instal-lation location immediately and close the door. Notify customer service.

    1.1.8. Instal l ing addit ional components

    The installation of additional components which have not been tested with the equipment may impair function. No liability is accepted and the guarantee becomes void in the event of damage caused for this reason.

    1.1.9. Instal lat ion room condit ions

    - Suffi cient ventilation - No heavy dust formation - No persistent air humidity - Frost-proof

    1.2. Navigator Control for HGL Technology

    The following functional description is applicable to IDM heat pumps type TERRA HGL with installed hot gas heat exchanger and Navigator Control.

    A prerequisite for the perfect operation of the control system is clean work by the heating engineer and electrician, as well as the proper commissioning of the control system by a trained IDM service engineer.

    1.3. Structure of the Navigator Control

    The Navigator Control is comprised of a central unit and the control unit. Furthermore, in accordance with requirements, an internal heating circuit expansion module for two additional heating circuits, as well as an external heating circuit expansion module for three additional heating circuits, can be connected. The central unit also has an interface for a GSM module as well as a stepper motor module.

    Via an SD card slot, on the actual central unit, it is possible to carry out evaluations using an event log.

    For systems with additional electric heat-ing elements (eg convection heater,...) depending on the operation of the system additional costs can occur.

    As a connection cable between the control unit and the mainboard only the provided cable is allowed to be used Tak-ing off the control unit is not possible.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 7

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    NAVIGATOR 1.0

    F1

    F2

    F1

    F2

    Op

    era

    tio

    n

    2. Operation

    2.1. Operat ion using the Control Uni t

    The heat pump is put into operation via the main switch. After actuating the main switch, the Navigator Control starts automatically.

    In systems that are already confi gured the main menu appears on the LCD after initialisation.

    The operation of the Navigator Control is performed using the control unit. The control unit enables easy menu-driven operation on the LCD using 6 membrane keys.

    2.2. Displays in the Main Menu

    In the main menu the fi ve submenus are shown by way of symbols. By using the arrow keys it is possible to select the individual menu symbols. The submenus are described in greater detail further ahead.

    The heat pump status is shown on the status display on the right-hand screen edge. Using the F1 key it is possible to change between the individual status bars HC(), Info and System.

    By using both arrow keys it is possible to move between the individual menu items. The symbol currently selected has a black background.

    By using the selection keys to the left and right of the arrow keys, the command with the black background at the top of the LCD can be executed.

    Using the F1 key, it is possible to change between the status displays on the right-hand edge of the screen. The status dis-plays will be described in greater detail further ahead.

    Using the F2 key, the system can be switched off or switched on again re-spectively.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    2. Allgemeine Beschreibung

    Operating Manual NAV 1.08

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    Cold reservoir temperature

    Hygienik temperature

    Flow temp. heat pump

    Heat source temp.

    Heat pump in priority mode

    Heating stage

    Buffer tank temperature

    Current outside temp.

    Mean outside temp.

    Current time

    Current date

    Room temp. set value

    Room temp. real value or status room thermostat

    Flow temp. set value

    Flow temp. real value

    Heating circuit in heating mode

    solar-temperature

    solar-status

    actual heat quantity solar

    Operation

    Op

    era

    tion

    Info status bar In the Info status bar, the current outside temperature is displayed on the outside sensor. The mean out-side temperature is calculated over a period of time (usually 16 hours). Furthermore, the current time and the date are shown.

    System status bar

    In the System status bar, the temperatures for the buffer tank, cold reservoir, Hygienik, heat pump fl ow and heat source are displayed. In cascade systems, the heating stage shows the number of stages in operation.

    Heating circuit status barIn the heating circuit status bar the most important data for the individual heating circuits are listed. An individual status bar is displayed for each param-eterised heating circuit. The status bar header shows which heating circuit is currently activated.

    2.3. Displays in the Status Bar

    Temperature values are only shown for those devices that are confi gured in the engineer level.

    Solar status bar

    For the Solarcontrol an additonal status bar is dis-played. In the Solar status bar the actual collector temperature, the actual heat quantity and the solar mode is shown.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 9

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    q

    q

    7

    X

    e1

    2

    Operation

    Op

    era

    tio

    n

    Description of symbols

    Operation according to the heating program

    Thermostat open - HC pump off

    Thermostat closed - HC pump on

    System / heating circuit in heating mode

    Pump heating circuit in operation

    Mixer heating circuit open

    Mixer heating circuit closed

    Priority mode

    Party function - active Holiday function - active

    Heating circuit permanent in normal mode

    Symbol for cooling mode

    Blocking time active

    External stage active

    Heating circuit permanent in ECO mode

    Heating stage 1

    External priority mode active

    Floor screed heating active

    defrosting active

    sum. signal zone valves no request

    status Solar mode "OFF"

    Regeneration of the heatsource via Solar active

    sum. signal zone valves re-quest active

    Poolheating via Solar active

    Heating stage 2

    manual mode

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    3. Allgemeine Beschreibung

    Operating Manual NAV 1.010

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    Op

    era

    ting

    mo

    de

    s

    3. Operating modes

    3.1. Operat ing Modes via the Main Menu

    The individual heating circuits can be parameterised via the submenu "Operating Modes".

    In order to access the "Operating Modes" menu, use the arrow keys to select the symbol for operating modes in the main menu. As soon as the symbol has a black background, it is possible to open the respec-tive subprogram by using the right-hand selection key.

    In the operating mode menu, the operating modes of the system in the individual heating circuits can be selected.

    By using the arrow keys it is possible to move between the menu items. The current set status is always dis-played (e.g. operating mode System - Automatic) on the right next to the operating function.

    In order to carry out a setting, the desired menu item (e.g. operating mode System) must have a black background. The respective submenu can be accessed by using the right-hand selection key. It is possible to return to the superordinate menu using the left-hand selection key and the command "Back".

    Depending on the parameterisation of the heat pump, only the heating circuits using the operating mode menu are shown.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 11

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    Operating modes

    Op

    era

    tin

    g m

    od

    es

    3.1.1. System operat ing mode

    In the submenu for the System operating mode it is possible to select between the functions Off, Auto-matic and Tapwater. Usually the Automatic function is set. The arrow keys are used to change between the operating modes.

    System operating modes parametersPar. No. Name DescriptionPROGO Off The heat pump is not in operation unless the frost-proof function is active.PROGO Automatic The heat pump runs in the heating mode in accordance with the set heating

    times. PROGO Hot water The heat pump only runs for storage tank charging without heating mode.PROGO Tapwater charging once

    onlyThe heat pump performs the one storage tank charging procedure. After comple-tion of the storage tank charging, the heat pump continues to run in the previous operating mode.

    3.1.2. Hol iday program

    In the holiday program submenu it is possible to set a date range during which the heating and cooling circuits can be operated in the ECO mode. During this time storage tank charging is carried out.

    After the set holiday program has elapsed, all the consumers are administered in accordance with the timer program.

    The date for the holiday program can be set by using the right-hand selection key and the arrow keys. After completing the setting, the date is saved using the right-hand selection key.

    3.1.3. Par ty funct ion

    The consumers are controlled by the ECO mode up to the end date / time entered.

    The setting is carried out using the right-hand selec-tion key and the arrow keys. After completing the set-ting, the date and time are saved using the right-hand selection key.

    The party function is only active if the indi-vidual heating and cooling circuits are set to automatic (timer program).

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    3. Allgemeine Beschreibung

    Operating Manual NAV 1.012

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    Operating modes

    Op

    era

    ting

    mo

    de

    s

    3.1.4. HC mode

    All parameterised heating circuits are shown in the operating modes menu. It is possible to change between operating modes for the respective heating circuits using the arrow keys.

    Heating circuit operating modes parametersPar. No. Name DescriptionHC..01 Off The heating circuit is not in operation unless the frost-proof function is active.HC..01 Timer program The heating circuit is operated according to the set heating times with Day set

    room temperature. Four heating times can be set per day for the heating circuit.HC..01 Normal The heating circuit is operated constantly with the Normal Heating set room

    temperature. HC..01 ECO The heating circuit is operated constantly with the ECO Heating set room

    temperature.HC..01 Manual heating The outside temperature for the calculation of the individual heating circuits is

    replaced with 7C.HC..01 Manual cooling The individual circuits

    With an outdoor temperature below the anti freeze outdoor temperature , the anti freeze for the de-activated heating circuits is switched on. With active anti freeze, the heating circuits are regulated to the anti freeze fl ow temperature.

    Parameter solar operating modesPar. No. Name DescriptionSC002 Automatic The setting 'automatic' automatically executes the respective function via the

    machine confi guration according to function priority.SC002 HYGIENIK The setting 'hygienik' uses the solar charge for the hygienik exclusively.

    3.1.5. Solar operat ion

    In case of solar control via the Navigator controller, the additional operating modes menu item

    3.1.5.1 Solar operat ion with f in tube heat exchanger

    With the TERRA SW 6-17 BA/HGL C a simple solar solar control (difference temperature control) is pos-sible as standard. No addtional solar control board is necessary.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 13

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    Operating modes

    Op

    era

    tin

    g m

    od

    es

    3.1.5.2 Solar operat ion with layered supply

    With an additional solar board a layered supply overa late heat exchanger station is possible. The additional board has to be connected with a CAN-bus cable to the navigator.

    Parameter solar operating modesPar. No. Name DescriptionSC002 Automatic The setting 'automatic' automatically executes the respective function via the

    machine confi guration according to function priority.

    SC002 Hygienik The setting 'hygienik' uses the solar charge for the hygienik exclusively.

    SC002 Buffer tank The setting 'heating buffer' uses the solar charge for the heating buffer exclusively.

    SC002 Hygienik + buffer tank The setting "hygienik + buffer tank" uses the solar charging for the hygienik and the buffer tank.

    SC002 Heating source / pool The setting heating source / pool uses the solar charge exclusively for supply of the heating source's brine circuit or for pool heating.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    4. Allgemeine Beschreibung

    Operating Manual14

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    Tem

    pe

    ratu

    re S

    ettin

    gs

    4. Temperature Settings

    4.1. Temperature Set t ings via the Main Menu

    With the item "temperature" in the main menu the temperatures for tap water capture, priority charging, heating circuits, solar control and for bivalence function can be set.

    4.1.1. Fresh water temperature set t ing

    Parameter fresh water temperaturePar. No.

    Name Description

    FW030 Fresh water set temperature (46C)

    The fresh water temperature gives the set temperature for the tapwater capture. It is possible to carry out this setting over the temperature range from 35.00C to 60.00C. The desired set temperature is set using the arrow keys. The new temperature value is confi rmed by using the right-hand selection key.

    Upon delivery of the equipment, the default value is set at 46.00C.

    Note: 60C is only possible for heat pumps using the refrigerant R134a.FW041 run time circulation

    (10 min)This parameter gives the run time (0-60 min) for the circulation pump.

    FW042 break time circulation (30 min)

    This parameter gives the break time (0-240 min) for the circulation pump.

    4.1.2. Temperature set t ing prior i ty charge

    This parameters gives the start- and stop temperature for priority charging.

    Parameter priority charging temperaturePar. No.

    Name Description

    FW028 max. priority charging temp. (50C)

    This parameter gives the set temperature (50-53C), when the priority charging stops (switch-off condition).

    FW027 min. priority charging temp. (46C)

    This parameter gives the set temperature (30-50C), when the priority charging starts (switch-on condition).

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual 15

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    Temperature Settings

    Tem

    pe

    ratu

    re S

    ett

    ing

    s

    Parameter heating circuit temperaturesPar. No.

    Name Description

    HKx04 Room temp. heating normal (22C)

    The room temperature heating normal can be set in a range from 15.00C up to 30.00C. The time where the temperature are hold, depends on the selected heating program.

    HKx05 Room temp. heating ECO (18C)

    The room temperature heating ECO gives the temperature outside the selected heating time.

    The room temperature heating ECO can be set between 10.00C and 25.00C.HKx08 Heating limit (16C) For mixer and uncontrolled heating circuits a heating limit can be set in the user

    menu above which the heating mode is blocked.

    Above this averaged outside temperature (16h) no heating requirement occured from the heating circuit. The heating limit will be deactivated with setting 0.

    HKx09 Room infl uence (1.0C) The room infl uence factor (0.0-4.0) shows to what extent the control system re-acts to the room temperature.

    If the room unit is assembled in a room affected by other heat sources (e.g. a tiled stove) a smaller proportion should be selected. The temperature of the room in which the room unit is assembled, also affects the heating of the other rooms.

    Note: Parameter is only visible in the case of confi gured room unit. HKx10 Heating curve (1.20) Given the steepness of the characteristic heating curve (0.10-3.50), the relation

    between the outside temperature and the required fl ow temperature is established.

    The greater the steepness of the characteristic curve is set, the higher is the fl ow temperature for the heating system depending on the outside temperature as well as on the heating and cooling limits (see fi gure heating curve page 19).

    45

    50

    55

    60

    65

    [C]

    0,8

    1

    1,2

    1,4

    1,6

    1,82

    2,22,42,6

    20

    25

    30

    35

    40

    Flow

    tem

    pera

    ture

    Outside temperature [C]

    0,4

    0,6

    4.1.3. Temperature set t ing heat ing c ircui ts

    The adjustable parameters for the heating circuit temperatures are depending on the confi guration of the heat pump. Only the relevant, according to the machine confi gu-ration set parameters, are displayed.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    4. Allgemeine Beschreibung

    Operating Manual16

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    Temperature Settings

    Tem

    pe

    ratu

    re S

    ettin

    gs

    Operating mode switch

    Positioning wheel

    In cooling mode, the room unit records a defrosting point via the humidity and the room tempera-ture is a humidity sensor is used in combination with room units. Recording the defrosting point causes a fl ow temperature adjustment, which prevents dropping below the defrosting point and therefore any possible humidity damage to the cooling operation!In order to avoid distorting the defrosting point calculation, the positioning wheel on the room unit must be set to the middle during cooling operation. In case of a deviation from this setting on the positioning wheel, the controller will report a false room temperature value, which infl uences the defrosting point monitoring.

    For correct temperature monitoring, the po-sitioning wheel for room units in combination with a humidity sensor must be set to the mid-dle value during cooling operation, and this may not be changed!

    Parameter heating circuit temperaturesPar. No.

    Name Description

    HKx50 Normal cooling room temperature (23C)

    The room temperature cooling normal can be set between 15.00C and 30.00C.

    HKx51 ECO cooling temperature ECO (25C)

    Parameter for the desired room temperature during ECO Cooling mode.

    HKx53 Cooling fl ow (18C) The fl ow temperature of the cooling cicruit can be set between 08.00C and 30.00C

    HKx54 Dew-point gap (2C) Displays the minimum temperature difference (1-10C) between the dew-point (room humidity sensor) and the set fl ow temperature.

    HKx08 Cooling limit (25C) Below this outside temperature (average time 16h) no cooling demand will be generated for the heating circuit.

    HKx59 Add-on time (15 min.) The Add-on time specifi es the time (1-240 min) that the fl ow temperature must lie under the lead temperature until the heatpump is requested.

    HKx14 Start screed program The parameter "start screed heating" will be displayed when the screed heat-ing is confi gurated. Now the program can be started once. After fi nishing the program the parameter is hidden again.

    4.1.3.1. Room temperature monitor ing via room uni t

    The current room temperature is transmitted to the Navigator controller via the room unit. The positioning wheel enables a temperature correction to be made for the room temperature.

    The operating mode switch may be used to switch operating modes for the respective heating circuit between the modes "off", "normal operation", ECO operation", "automatic operation". The operating mode switch is possible for cooling and heating.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual 17

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    Temperature Settings

    Tem

    pe

    ratu

    re S

    ett

    ing

    s

    parameter solar control (only if solar control is present)Par. No. Name DescriptionSC011 Solar comfort hygienik

    (70%)This parameter sets dropping of the hygienik temperature below the target tem-perature without requiring another heating source than the solar. This enables improved use of the solar energy.Setting range 0 - 100%

    Setting 100% - no dropping is allowedSetting 0% - a drop of up to 15% of the target temperature is permitted

    The solar comfort parameter simultaneously infl uences the time in which the drop is effective. Setting 100% - 3hSetting 0% - 48h

    SC013 Solar comfort buffer (70%)

    This parameter sets dropping of the buffer temperature below the target tem-perature without requiring another heating source than the solar. This enables improved use of the solar energy.Setting range 0 - 100%

    Setting 100% - no dropping is allowedSetting 0% - a drop of up to 10% of the target temperature is permitted

    The solar comfort parameter simultaneously infl uences the time in which the drop is effective. Setting 100% - 3hSetting 0% - 48h

    SC006 Max. temperature hygienik (80%)

    Parameter (50-90C) for maximum temperature limit in the hygienik

    SC007 Max. temperature buffer (80%)

    Parameter (50-90C) for maximum temperature limit in the buffer

    SC003 Pool set temperature (24C)

    If the pool is heated by the solar system, this parameter confi gures the target temperature (18-36C) for the pool. This parameter is only visible if pool heating is confi gured.

    SC133 Collector defrosting time (20min)

    Defrosting time (0-60min) for defrosting the collector

    SC134 Collector defrosting Parameter (Yes/No) for starting defrost function

    4.1.4. Temperature set t ings solar faci l i ty

    If the Navigator controller is used for solar control, the additional parameter menu "solar control" is shown in the "temperatures" icon menu.

    Following settings can be changed via the solar con-trol menu item:

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    4. Allgemeine Beschreibung

    Operating Manual18

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    Temperature Settings

    Tem

    pe

    ratu

    re S

    ettin

    gs

    4.1.5. Temperature set t ing bivalence

    The adjustable parameters are based on the machine confi guration. By confi guration bivalence "parallel" and bivalence "alternative" an bivalence point is shown in this menu point.

    Bivalence parallel: Below this temperature, the secound heat generator starts, when the heat pump dont reach the set temperature of the heat circuit.

    Bivalence alternative: Below this temperature the second heat generator runs only. The heat pump is controlled no longer.

    Parameter bivalencePar. No.

    Name Description

    BV002 Bivalence point 1 (0C) When bivalence strategy "parallel" is set, the second heat generator starts under current outside temperature range between -20C and +20C, if the heat pump dont reach the set temperature of the heat circuit over a certain period. When bivalence strategy "alternative" is set, the heat pump dont run under this temperature value, that means only the second heat generator runs.

    BV003 Bivalence point 2 (-10C) When bivalence strategy "parallel/alternative" is set, the heat pump is not controlled below the temperature range between -20C and +20C current outside temperature. Only the second heat generator runs.

    4.1.6. Temperature set t ing Smar t Grid

    The Smard Grid input enables the use of benefi cial electric current respectively electric current free of charge from the PV-collector. This benefi cial/free of charge electric current are used for water heating respectively to infl ate the temperature of the heating system.

    Parameter Smart GridPar. No.

    Name Description

    PV002 hot water generation If this parameter is set to "Yes", the heat pump execute hot water loading (also outside of the hot water charging time).

    PV003 buffer temperature infl ate (0.0K)

    This parameter (0.0K - 5.0K) indicates the infl ate of the buffer.

    PV004 fl oor heating infl ate (0.0K) This parameter (0.0K - 2.0K) indicates the infl ate of the fl oor heating.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual 19

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    Temperature Settings

    Tem

    pe

    ratu

    re S

    ett

    ing

    s

    4550556065

    [C]

    0,8

    1

    1,2

    1,4

    1,6

    1,8

    22,2

    2,4

    2,6

    2025303540

    Flow temperature

    Out

    side

    tem

    pera

    ture

    [C]

    0,4

    0,6

    Heating curve / Characteristic line

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    5. Allgemeine Beschreibung

    Operating Manual NAV 1.020

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    5

    Time

    Se

    tting

    s

    5. Time Settings

    5.1. T ime Set t ings via the Main Menu

    All time settings can be carried out on the control system under the third menu item.

    5.1.1. Date and t ime

    The date and time can be set in the submenu "Times".

    In order to carry out the setting, "Date/Time" must be selected from the Times - Menu. The respective submenu can be accessed by using the right-hand selection key.

    In the "Date and Time" menu, in order to carry out the setting, the right-hand selection key must be used to select the function "Change".

    Subsequently, the arrow keys can be used to modify the respective established value. The next setting value can be accessed by using the right-hand selec-tion key.

    Once all values have been set, the new setting can be saved using the right-hand selection key.

    The changeover between summertime and wintertime is automatically carried out by the control system.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 21

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    5

    Time Settings

    Tim

    e S

    ett

    ing

    s

    5.1.2. Program prior i ty set t ing

    By using the time setting "Program Priority", times can be established during which a priority storage tank charging takes place. The storage tank charg-ing is preferentially carried out prior to heating up the heating circuits.

    During the priority charging procedure, the heating, when operating with a Hygienik, is not supplied with heat. When using an additional buffer accumulator, the supply to the heating circuits is guaranteed via the additional buffer accumulator in the priority charging mode.

    During the priority charging procedure, the speed of the charging pump and, as such, the throughput through the condenser and the HGL exchanger, is reduced to the extent that the accumulator is once again charged with the desired HGL temperature (e.g. 58C).

    Procedure for setting the time:

    It is possible to set an arbitrary number of times for the priority charging for each weekday.

    Under the menu item Program Priority it is possible to change between the individual functions via the left-hand selection button. The respective function is selected using the right-hand selection key.

    Once the desired day has been chosen, the left-hand selection key is used to select the Change function.

    By using the right-hand selection key, the time for Activ (priority charging) and Inactiv (no priority charg-ing) can be set.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    5. Allgemeine Beschreibung

    Operating Manual NAV 1.022

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    5

    Time Settings

    Time

    Se

    tting

    s

    Setting the times using the cursor:

    The Cursor function is selected by using the right-hand selection key. The current status for the cursor is displayed directly above the right-hand selection key.

    Position Cursor - The cursor can be displaced along the time bar without having any effect

    Cursor Activ - The cursor marks the time range for "Priority charging". By displacing the cursor with the arrow keys the bar above has a dark background.

    Cursor Inactiv - The cursor marks the time range for "No Priority charging". By displacing the cursor with the arrow keys the bar above has a light background.

    The times for Activ or Inactiv can be arbitrarily set.

    Copying the settings to another day:

    The settings can be copied to another day. To do so the day to be copied must be active. By using the left-hand selection key the Copy function is selected and the right-hand selection key is used to carry out the action. Subsequently, the desired day to which the settings are to be copied is selected. By using the left-hand selection key the Paste function is selected and the right-hand selection key is used to carry out the action.

    With the function Paste all the settings of the selected day can be copied to all days.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 23

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    5

    Time Settings

    Tim

    e S

    ett

    ing

    s

    5.1.4. Set t ing EVU blocking t ime

    The blocking time must be maintained by the respec-tive EVU. It can be set in the menu "EVU Blocking Time". The entered blocking time is applicable to each day.

    These times can be set to a min. time interval of 0.5 hours.

    5.1.3. Heat ing c ircui t program set t ing

    In the "Program HC .." the times for the heating mode of the heating circuits to be parameterised can be set.

    For each heating circuit, it is possible to set up to 24 heating times for each day selected. The setting for the heating times is carried out as described for setting the times in Program Priority mode.

    Normal - dark bar - Heating mode at room temp. Normal Heating

    ECO - light bar - Heating mode at room temp. ECO Heating

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    5. Allgemeine Beschreibung

    Operating Manual NAV 1.024

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    5

    Time Settings

    Time

    Se

    tting

    s

    5.1.5. Fan speed reduct ion in the CL vers ion

    The fan speed reduction can be set for Terra CL heat pumps. By using the fan speed reduction function, times can be set during which the fan speed on the evaporator is reduced.

    The reduced speed is set by the manufacturer and can only be modifi ed by customer service.

    5.1.6. Circulat ion t imes

    With the Navigator control it is possible to actuate a circulation pump. The circulation has to be installed and set in the service mode

    A tap water circulation can be controlled by the Navigator control at all TERRA HGL machines. With TERRA heat pumps the circulation control is not possible.Exception: TERRA SW 6-17 (HGL) Com-plete

    A tap water circulation can be controlled by the Navigator control with BA and HGL machines., when the output on the Naviga-tor controller is not used as a "Common alarm output"!

  • 12

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    D I E E N E R G I E FA M I L I E

    (C) IDM ENERGIESYSTEME GMBH 25MyIDM - Dienstleistungsplattform

    1

    2

    3

    4

    5

    6

    21

    Connector LAN X33 on the Navigator main board

    MyIDM - Dienstleistungsplattform

    My

    IDM

    6. MyIDM - service platform6.1. Integrat ion of the heat pump into the

    Internet

    With the Smartphone App for IDM Navigator control-ler, heatpumps which are connected with the internet, can be operated and monitored by smartphone.

    Therefor is in addition to an internet connection, the download of the Apps from the App Store respectively Play Store a registration at IDM-Energiesysteme re-quired.

    The integration of the heat pump into the network occured over the socket LAN X33 on the Navigator main board by a network cable. This cable must be supplied on site.

    To allow an access to the heat pump via the Navigator Apps for Smartphones, the local IP, the subnetmask and the standardgateway must be registered in the Navigator controller. The values must be set as de-scribed as follows.

    It is not allowed to connect the network cable to another socket. Otherwise the Navigator main board can be destructed.

    The Navigator App can be downloa-ded from App Store (IOS) respectively Play Store (Android).

    The yellow LED (1) on the socket lights, as soon as an connection to the network, switch, hub or similar exists.

    The green LED (2) on the socket blinks, as soon as an data exchange occured.

    For the network communication Na-vigator - myIDM the ports 55555 and 55443 must be free/open!

  • 12

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    D I E E N E R G I E FA M I L I E

    (C) IDM ENERGIESYSTEME GMBH

    MyIDM - service platform

    MyIDM - Dienstleistungsplattform26

    1

    2

    3

    4

    5

    6

    MyIDM - Dienstleistungsplattform

    My

    IDM

    6.2. Configurat ion of the heat pump

    Mark the menu item Information in the main menu over the cursor key and confi rm with the right button (enter).

    Choose with the cursor key Network setup and confi rm with the right button (enter).

    Choose the menu item Information with the right button (enter).

    The display now shows myIDM not connected, so no connection to the myIDM website is established

    On the following pages is discribed how to establish a connection.

    To establish the connection with the myIDM-Website set the parameter DHCP (only with Navigator 1.7 possible) to yes, then the heatpump gets automa-tically the network adress assigned (if on the router DHCP-Server is activated)

    or choose network setup (enter) and do the network adresses manually.

  • 12

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    D I E E N E R G I E FA M I L I E

    (C) IDM ENERGIESYSTEME GMBH 27MyIDM - Dienstleistungsplattform

    1

    2

    3

    4

    5

    6

    MyIDM - Dienstleistungsplattform

    My

    IDM

    Register the Local IP, the Subnetmask and the Standardgateway in this menu item.

    For it, press the right function button (change). The cursor jumps to the fi rst 3-digit number of the Local IP

    Set the fi rst 3-digit number of the Local IP with the arrow button (Up/Down). Change to the next 3-digit number with the right function button () and set with the arrow button (Up/Down). Repeat this opera-ting sequence until all 3-digit numbers are set

    After reaching the last 3-digit number for the Standardgateway the right function key get the function Save. By pressing the right function button (enter), the adresses are stored.

    The specifi ed values for Local IP, Subnetmask and Standardgateway in this example are just samples and must not match the actual needed values of existing networks!

  • 12

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    D I E E N E R G I E FA M I L I E

    (C) IDM ENERGIESYSTEME GMBH

    MyIDM - service platform

    MyIDM - Dienstleistungsplattform28

    1

    2

    3

    4

    5

    6

    MyIDM - Dienstleistungsplattform

    My

    IDM

    To establish the connection with myIDM choose the menu item Network setting and confi rm with the right button (enter).

    Set the parameter myIDM to Yes and confi rm with the right function button (enter).

    Now switch-off and switch-on the Navigator controller with button F2 (reboot).

    The myIDMID is displayed under Information/Network setting/Information.

    Register on the website www.myidm.at. Note the myIDMID. This ID will be needed for registration.

  • 12

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    D I E E N E R G I E FA M I L I E

    (C) IDM ENERGIESYSTEME GMBH 29MyIDM - Dienstleistungsplattform

    1

    2

    3

    4

    5

    6

    MyIDM - Dienstleistungsplattform

    My

    IDM

    6.3. Registrat ion

    Before you can use the various applications, you must register on ww.myidm.at.

    After entering the adress (e.g. Internet Explorer) the myidm startpage appears. For registration choose Register.

    Ony a valid email adress, the password (must con-tain a combination of letters,numbers and a special character like # $ ! ...), given name and surname, die Anschrift the adress and the telephone number (all fi elds are mandatory fi elds).

    Confi rm the data with one click on sign up.

    If you lost your password, click on forgot-ten password, type in your email adress and request a new password.

  • 12

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    D I E E N E R G I E FA M I L I E

    (C) IDM ENERGIESYSTEME GMBH

    MyIDM - service platform

    MyIDM - Dienstleistungsplattform30

    1

    2

    3

    4

    5

    6

    MyIDM - Dienstleistungsplattform

    My

    IDM

    To add an IDM heat pump (your own system), select the menu item Add my system.

    Enter your myIDMID (see Navigator control Informa-tion/Network settings/Information), the serial number (see type plate), the postal code (for the system location) and the system name (max. 50 characters).

    Then press Save to confi rm your input

    You have now added the heat pump, which then appears under My heat pumps. It will be activated by IDM Energiesysteme.Once IDM Energiesysteme GmbH as completed the activation, the entry for Acti-ve will read Yes.

    You can edit these entries at any time below Options (to do so, press the read/write icon for Options). Options [x] lets you delete the system.

    Selecting the read/write icon (for Options) lets you change the heat pumps name or the postal code in the Overview menu item..

  • 12

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    D I E E N E R G I E FA M I L I E

    (C) IDM ENERGIESYSTEME GMBH 31MyIDM - Dienstleistungsplattform

    1

    2

    3

    4

    5

    6

    MyIDM - Dienstleistungsplattform

    My

    IDM

    You can use the Settings menu, for example, to rename the heating circuit.

    myIDMComplete can only be enabled in combinati-on with the conclusion of a service agreement.

    The system owner can use the Authorisations menu item to sign authorisations and create new users (ser-vice, heating company, guest, etc.) who are permitted to access the system.

    To do service select Create user and then enter the e-mail address of the user in question (the user must be registered with myIDM); then enter the user type and click on Add.

    The system owner can defi ne their own user types, or, for example, assign/restrict authorisations of the Guest user.

    You can use the FileCenter menu item to upload data (logfi les).

    You can download the app for smart phones and/or the Smart Navigator (Remote Control Software) using the SMART APPs menu item.

    The rights for the particular usertypes are prede ned by IDM Energiesysteme GmbH

  • 12

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    D I E E N E R G I E FA M I L I E

    (C) IDM ENERGIESYSTEME GMBH

    MyIDM - service platform

    MyIDM - Dienstleistungsplattform32

    1

    2

    3

    4

    5

    6

    MyIDM - Dienstleistungsplattform

    My

    IDM

    If you select, Android or iOS, you are taken to the download page for the Android app or iPhone app

    You can download the Smart Navigator (Remote Control Software) for your laptop/PC by selecting Windows.

  • 12

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    D I E E N E R G I E FA M I L I E

    (C) IDM ENERGIESYSTEME GMBH 33MyIDM - Dienstleistungsplattform

    1

    2

    3

    4

    5

    6

    MyIDM - Dienstleistungsplattform

    My

    IDM

    With small smartphone-displays pro-blems with the displaying can occur

    6.4. Smar t phone based control

    After downloading the smart phone app from the App Store or Play Store, you can open the app on your smart phone

    To login, use your access credentials (e-mail address and password), which you entered when you regis-tered with myIDM (IDM Energiesysteme must have released your account for this).

    Then select the system in question.

    Several systems may appear, depending on the num-ber of systems the user (service) has created.

    In the user interface, you can now select the desired menu item (system overview, hygienik, etc.) depen-ding on the system confi guration and release (by IDM Energiesysteme)

    The Change system lets you change to another system created by the user

  • 12

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    D I E E N E R G I E FA M I L I E

    (C) IDM ENERGIESYSTEME GMBH

    MyIDM - service platform

    MyIDM - Dienstleistungsplattform34

    1

    2

    3

    4

    5

    6

    MyIDM - Dienstleistungsplattform

    My

    IDM

    The System overview menu item shows you the current outside temperature, the heat accumulator temperature, the heat volume and the current opera-ting mode (status).

    You can change the systems operating mode (Auto stands for automatic mode) by selecting the icon with the Pencil symbol.

    The Hygienik menu item shows the hygiene tem-perature (hot water) and the heat accumulator tem-perature.

    The Heating circuits shows you the target room temperature, the actual room temperature and the supply temperature of each heating circuit as well as the current operating mode (status).

    You can change the target room temperature and the systems operating mode by selecting the icon with the Pencil symbol.

  • 12

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    D I E E N E R G I E FA M I L I E

    (C) IDM ENERGIESYSTEME GMBH 35MyIDM - Dienstleistungsplattform

    1

    2

    3

    4

    5

    6

    MyIDM - Dienstleistungsplattform

    My

    IDM

    The Solar system shows you the collector tempe-rature, the solar load temperature and the current operating mode (status).

    Die Betriebsart der Solaranlage kann durch anwh-len des Icons mit dem Bleistift-Symbol gendert werden.

    You can change the solar systems operating mode by selecting the icon with the Pencil symbol.

    3h ... 3 hours 1d ... 1 day 3d ... 3 days 1W ... 1 week

    The Histogram menu item shows the heating circuit temperatures and visualises them graphically. The logging period is confi gurable.

    3h ... 3 hours 1d ... 1 day 3d ... 3 days 1W ... 1 week

  • 12

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    D I E E N E R G I E FA M I L I E

    (C) IDM ENERGIESYSTEME GMBH

    MyIDM - service platform

    MyIDM - Dienstleistungsplattform36

    1

    2

    3

    4

    5

    6

    MyIDM - Dienstleistungsplattform

    My

    IDM

    The Histogram menu item shows the solar tempe-ratures and visualises them graphically. The logging period is confi gurable.

    3h ... 3 hours 1d ... 1 day 3d ... 3 days 1W ... 1 week

    You can use the Navigator menu item to operate the Navigator control (settings can be changed).

    Access to the service level Spanner icon is reserved for trained IDM-Energiesysteme service engineers.

    The Logout quits the apps interface and takes you back to Login.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 37

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    5

    6

    Info

    rma

    tio

    n

    7. Information

    7.1. Information via the Main Menu

    Under the fourth menu item of the main menu, various status requests regarding the system can be made.

    7.1.1. Inputs / outputs

    Via the Inputs / Outputs Menu, the status of all inputs (sensors, digital inputs), as well as the status of the outputs ( analogue outputs, digital outputs) can be requested.

    The status request can be helpful during start-up as well as when solving errors.

    Requests Inputs / OutputsPar. No.

    Name Description

    - Sensor Current temperatures of the respective sensor in C- Digital inputs Status of the digital inputs (O- Open, C - Closed)- Analogue outputs Display of the voltage at the outputs (0-10V)

    Display of the modulation in %- Digital outputs Status (Off - On)- Bus connection This is where the current status of the cascades CAN - Bus participants is displayed.

    7.1.2. System information

    In the submenu System Information, the current software version, as well as the total times for the individual operating modes, the running times for the heating stages and the switching signals of the heating stages that have been performed by the heat pump are shown in hours.

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    7. Allgemeine Beschreibung

    Operating Manual NAV 1.038

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    5

    6

    Information

    Info

    rma

    tion

    7.1.4. Networksetup

    Via menu "Network setup" information regarding to network connection can be inquired. It is possible to set the network adress manually or automaticalliy via DHCP.

    The connection to the "myIDM service platform" is displayed in the submenu "Information".

    MyIDM registration under website "myidm.idm-energie.at"

    7.1.5. Cascade system

    The menu 'cascade system' allows the status of the individual stages to be queried.

    The menu item 'cascade system' is only visible if the cas-cade is confi gured. The percentage value indicates how much percent is required for the respective operation.

    7.1.6. Reset Data

    Via the menu reset data, the heat meter can be reseted

    7.1.3. Heat meter

    If a heat meter is installed, under the menu item Heat Meter it is possible to request the heating and cooling performance in [kW]. Furthermore, the cur-rent actual performance of HP fl ow and HGL fl ow is shown in [W].

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 39

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    5

    6

    Information

    Info

    rma

    tio

    n

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    8. Allgemeine Beschreibung

    Operating Manual NAV 1.040

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    5

    6

    7

    Fau

    lts

    8. Faults

    8.1. Error Display in the Main Menu

    When an error occurs an error notifi cation is shown on the display.

    Via the left-hand selection key it is possible to access the submenu Error where a more detailed description of the error is given.

    Sensor errorError No.

    Designation Description

    100 Outside sensor (B32) Short circuit101 Interruption102 Heat pump fl ow sensor (B33) Short circuit103 Interruption104 HGL fl ow sensor (B35) Short circuit105 Interruption106 Heat source sensor (B36) Short circuit107 Interruption108 Heat accumulator sensor (B39) Short circuit109 Interruption110 Cold reservoir sensor (B40) Short circuit111 Interruption112 Hygienik sensor (B41) Short circuit113 Interruption114 Fresh water station sensor (B42) Short circuit115 Interruption116 Flow sensor HC A (B51) Short circuit117 Interruption118 Flow sensor HC B (B52) Short circuit119 Interruption120 Room sensor HCA (B61) Short circuit121 Interruption122 Room sensor HCB (B62) Short circuit123 Interruption124 Hot gas sensor (B71) Short circuit125 Interruption126 Room humidity sensor (B31) Short circuit127 Interruption

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 41

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    5

    6

    7

    Sensor errorError No.

    Designation Description

    128 Low pressure sensor (B9) Short circuit129 Interruption130 Flow sensor HC C (B53) Short circuit131 Interruption132 Flow sensor HC D (B54) Short circuit133 Interruption134 Room sensor HC C (B63) Short circuit135 Interruption136 Room sensor HC D (B64) Short circuit137 Interruption138 Flow sensor HC E (B55) Short circuit139 Interruption140 Flow sensor HC F (B56) Short circuit141 Interruption142 Flow sensor HC G (B57) Short circuit143 Interruption144 Room sensor HC E (B65) Short circuit145 Interruption146 Room sensor HC F (B66) Short circuit147 Interruption148 Room sensor HC G (B67) Short circuit149 Interruption150 Evaporator outlet sensor (B79) Short circuit151 Interruption152 Evaporator pressure transmitter (B78) Short circuit153 Interruption154 Solar collector sensor (B73) Short circuit155 Interruption156 Solar loading sensor (B74) Short circuit157 Interruption158 Solar collector return fl ow sensor (B75) Short circuit159 Interruption160 Solar heat source reference sensor (B76) Short circuit161 Interruption162 Inlet air sensor (B37) Short circuit163 Interruption164 Air heat exchanger sensor (B72) Short circuit165 Interruption196 Difference temperature 1 sensor (B84) Short circuit197 Interruption198 Difference temperature 2 sensor (B85) Short circuit199 Interruption

    Faults

    Fau

    lts

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH

    8. Allgemeine Beschreibung

    Operating Manual NAV 1.042

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    5

    6

    7

    System errorError No. Designation Description020 Heat pump fl ow maximum temperature Heat pump fl ow temperature is above the set maximum tempera-

    ture.021 Heat pump fl ow minimum temperature Heat pump fl ow temperature is below the set minimum tempera-

    ture.022 Low pressure error The low pressure switch has switched off the heat pump (< 3 times

    in 24h).023 Low pressure error locked The low pressure switch has switched off the heat pump

    (> 3 times in 24h). The heat pump is no longer triggered. After the occurrence of the error 023 it is only allowed to un-lock one time.

    024 High pressure error The high pressure switch has switched off the heat pump (< 3 times in 24h).

    025 High pressure error locked The high pressure switch has switched off the heat pump (> 3 times in 24h). The heat pump is no longer triggered.

    026 Flow monitoring The fl ow switch in ground water systems has switched off the heat pump (< 3 times in 24h).

    027 Flow lock The fl ow switch in ground water systems has switched off the heat pump (> 3 times in 24h). The heat pump is no longer triggered.

    028 Start-up current limiter see LED Error start-up current limiter (< 5 times in 24h). The type of error is displayed on the start-up current limiter.

    029 Start-up current limiter 5x in 24h Error start-up current limiter (> 5 times in 24h). The heat pump is no longer triggered.

    030 Motor protection heat source pump The motor protection for the heat source pump has been triggered (< 5 times in 24h).

    031 Motor protection heat source 5x in 24h The motor protection for the heat source pump has been triggered (> 5 times in 24h). The heat pump is no longer triggered.

    032 Maximum defrosting time exceeded The maximum defrosting time has been exceeded.033 Minimum condenser temperature

    undershoot (only for TERRA SL)The heat pump has been switched off due to undershooting the minimum condenser temperature.

    034 Fan error The control system for the fan has detected a functional error.035 Min. buffer temperature for defrosting

    undershootIf the buffer temperature is under 20C, the defrosting is blocked. If the buffer temperature is under 10C, the defrosting is stopped.

    036 Electric immersion heater overheating The safety thermostat of the immersion heater has been activated.037 Loading pump The fault indication contact of the loading pump has been

    triggered.050 Dew-point monitoring device has been

    activatedThe set fl ow temperature in cooling mode is increased by 3K.

    051 Dew-point monitoring has been activated permanently

    The cooling mode is blocked by the dew-point monitoring.

    060 Heat source temperature The measured heat source outlet temperature undershoots the minimum heat source temperature.

    061 Warning heat source temperature The heat source outlet temperature reaches a critical value min. heat source temperature + 2K.

    062 Winding protection The compressor winding protection has been triggered (< 3 times in 24h)

    063 Winding protection interlock The compressor winding protection has been triggered (> 3 times in 24h). The heat pump is no longer actuated.

    Faults

    Fau

    lts

  • T H E P O W E R FA M I L Y

    (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 43

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    1

    2

    3

    4

    5

    6

    7

    System errorError No. Designation Description070 Error EIB/KNX module No EIB/KNX module is connected to the Navigator motherboard,

    meaning that the EIB/KNX module is not programmed.

    The error message is displayed with a time delay of 30 sec. after parameterisation of the EIB/KNX module. (initialisation time)

    074 Starting current limiter 2 - see LED Error starting current limiter of the 2nd compressor (> 5 times in 24h) The kind of error is displayed on the starting current limiter

    075 Starting current limiter 2 - 5x in 24h Error starting current limiter of the 2nd compressor (> 5 times in 24h) The heat pump is no longer actuated.

    080/280 Collector maximum temperature (only for solar control)

    The collector max. temperature has been exceeded. The error is automatically reset once this falls below the value again.

    081/281 Hygienik maximum temperature (only for solar control)

    The hygienik max. temperature has been exceeded. The error is automatically reset once this falls below the value again.

    082/282 Buffer maximum temperature (only for solar control)

    The max. buffer temperature has been exceeded. The error is automatically reset once this falls below the value again.

    083/283 Heat source maximum temperature (only for solar control)

    The max. heat source temperature has been exceeded. The error is automatically reset once this falls below the value again.

    084/284 Solar module not available No or defective communication between the solar module and the main board via the CAN bus if the solar controller is confi g-ured.

    090 Master not found Master-machine can not be found by slave-machine.091 Central unit 2 offl ine Platine A7 (TERRA MAX) is not recognized.200 Application limit reached

    (TERRA CL only)For Terra CL heat pumps, operation outside of the application limits switched off the heat pumps.

    221 Low pressure error The low pressure monitoring (TERRA MAX - 2nd compressor) switched off the heat pump (< 3 times in 24h)

    231 Low pressure error locked The low pressure monitoring (TERRA MAX - 2nd compressor) switched off the heat pump (> 3 times in 24h). The heat pump is no longer triggered.

    241 High pressure error The high pressure monitoring (TERRA MAX - 2nd compressor) switched off the heat pump (< 3 times in 24h).

    251 High pressure error locked The high pressure monitoring (TERRA MAX - 2nd compressor) switched off the heat pump (> 3 times in 24h). The heat pump is no longer triggered.

    280 Collector maximal temperature (only for solar control)

    The collector max. temperature has been exceeded. The error is automatically reset once this falls below the value again.

    281 Hygienik maximal temperature (only for solar control)

    The hygienik max. temperature has been exceeded. The error is automatically reset once this falls below the value again.

    282 Buffer maximal temperature (only for solar control)

    The max. buffer temperature has been exceeded. The error is automatically reset once this falls below the value again.

    283 Heat source maximal temperature (only for solar control)

    The max. heat source temperature has been exceeded. The error is automatically reset once this falls below the value again.

    284 solar module not available No or defective communication between the solar module and the main board via the CAN bus if the solar controller is confi g-ured.

    If a pressure switch or a thermal relay error occurs several times, please contact your IDM Customer Service.

    Faults

    Fau

    lts

    Faults

  • THE POWER FAMI LY

    Your IDM par tner

    Always there for you.IDM HEADQUARTERS IN EASTERN TYROL, AUSTRIA

    IDM ENERGIESYSTEME GMBH Seblas 16 18 A-9971 Matrei in Ost t iro l, Aus tr iaTelephone +43(0)4875.6172 - 0 Fax +43(0)4875.6172 - 85 E-mail [email protected]

    w w w. i d m - e n e r g i e . c o m

    IDM - ser vice technologyCOMMISSIONING SERVICING ON-SITE SERVICEOur ser vice technicians are happy to help on - si te. Contac t detai ls for your regional cus tomer ser vice centre can be found on our websi te www.idm-energie.com.

    IDM AcademyPRACTICAL KNOWLEDGE FOR SALES AND TECHNOLOGYThe comprehensive range of seminars for specialis t s at the IDM POWER FAMILY is available to you at al l t imes on our websi te www.idm-energie.com. We look forward to receiving your regis t rat ion.

    ONE STEP AHEAD*THE POWER FAMI LY

    IDM ENERGIESYSTEME GMBH Matrei i. Osttirol 17.06.13 Errors and omissions excepted

    THE POWER FAMI LY

    Your IDM par tner

    IDM HEADQUARTERS IN EASTERN TYROL, AUSTRIA

    IDM ENERGIESYSTEME GMBH Seblas 16 18 A-9971 Matrei in Ost t iro l, Aus tr iaTelephone +43(0)4875.6172 - 0 Fax +43(0)4875.6172 - 85 E-mail [email protected]

    w w w. i d m - e n e r g i e . c o m

    IDM Academy