What is Zone Control?

Zone Control is the practice of separately

controlling the temperature in different zones

of a building

Zone Control allows you to share time with one

piece of HVAC equipment in different zones

A “Zone” can be one room, several rooms, or

even a floor

Page 3: Fahrenheit Zone Control

Comfort vs. Cost – How About Both! Studies have been done on the potential cost savings

of zoning a home and have shown up to a possible 30% cost savings when a home is zoned correctly and used with setback thermostats

Everyone should feel comfortable in every room in their home but the fact is, due to many variables, one temperature controlled system cannot keep every area in a home at appropriate temperatures

Such variables could be whether a room (zone) faces the sun at certain times of the day or whether or not a zone is an underground floor (basement) or upstairs (2nd floor in a 2-story home)

.

Page 4: Fahrenheit Zone Control

Comfort vs. Cost – How About Both!

Page 5: Fahrenheit Zone Control

Zone Control System Components. 1. Control Panel – The “brains” of the system

2. Thermostats – Used to control the temperatures of each individual zone

Page 6: Fahrenheit Zone Control

Zone Control System Components3. Zone Dampers – A specific type of damper

that controls the flow of heating or cooling within the ductwork of a Zone Control System

Can be round or rectangular, side or bottom mount

Page 7: Fahrenheit Zone Control

Zone Control System Components.

4. Bypass Damper (optional component) – A damper that is strictly used in Zone Control Systems to relieve excess pressure that may form when zone dampers close

Can be round or rectangular, barometric (controlled by pressure within the system) or electric

Page 8: Fahrenheit Zone Control

Zone Control System Components 5. Accessories – Can include such parts

as transformers (all systems require a dedicated transformer), discharge air sensors (DAS), actuators and outdoor air temperature sensors (OTS)

Page 9: Fahrenheit Zone Control

Control PanelsCP-2 Control Panel – 2 ZonesThe Fahrenheit Series™ CP-2 forced air zoning systems represent the most contractor-friendly solution today. The CP-2 is a single-stage heat/cool panel designed to control 2 zones in residential and light commercial applications.

Features and Benefits• Auto changeover• First call priority with time share• Electronic discharge air sensor• LED status indication• Independent fan control by zone• Short cycle protection• Single stage (1H/1C)• Competitively priced• 10-year warranty

Page 10: Fahrenheit Zone Control

Control PanelsCP-3 Control Panel – 3 ZonesThe Fahrenheit Series™ CP-3 forced air zoning systems represent the most contractor-friendly solution today. The CP-3 is a multi-stage heat/cool panel designed to control conventional equipment and up to 3 zones in residential and light commercial applications.

Features and BenefitsMulti-Stage (3H/2C)Auto changeoverFirst call priority with time shareLED status indicationIndependent fan control by zoneShort cycle protectionPurge cycle

Page 11: Fahrenheit Zone Control

Control PanelsCP-3-HP Control Panel – 3 ZonesThe Fahrenheit Series™ CP-3-HP forced air zoning systems represent the most contractor-friendly solution today. The CP-3 is a multi-stage heat/cool panel with a built in dual fuel kit designed to control heat pump equipment and up to 3 zones in residential and light commercial applications.

Features and BenefitsHeat Pump (3H/2C)Auto changeoverFirst call priority with time shareLED status indicationIndependent fan control by zoneBuilt-in dual fuel kit

Page 12: Fahrenheit Zone Control

Control PanelsCP-6 Control Panel – 6 ZonesThe Fahrenheit Series™ CP-6 forced air zoning systems represent the perfect light commercial solution. The CP-6 is a multi-stage heat/cool panel with built in dual fuel kit and capable of operating heat pumps. It is designed to control up to 6 zones in residential and light commercial applications and is expandable to up to 12 zones (see CP-X).

Universal control at your fingertips!

Features and Benefits• Majority wins priority• Cooling priority• Ability to stage by thermostat or by adjustable timer• Adjustable hi/lo limits and balance points on the board• Heat/cool capacity control• Built-in dual fuel kit• Expandable to 12 zones in 3-zone increments (CP-X)

Page 13: Fahrenheit Zone Control

CZRD™ Combination Zone Relief Damper. The Combination Zone Relief Damper is a patented product that eliminates the need to install a bypass duct and damper in a zone control system. This is accomplished with a built-in static pressure relief mechanism that will modulate open once the static pressure within the duct has reached an unacceptable level. (Factory set at 0.3”WC)

The CZRD is the answer to many installation problems such as:•

Space limitations installing a bypass

• State regulations restricting a bypass

• Added cost of labor and materials to install a bypass

• All CZRD dampers work with any of the control panels

Page 14: Fahrenheit Zone Control

CZRD™ Combination Zone Relief Damper

Page 15: Fahrenheit Zone Control

CZRD™ Combination Zone Relief Damper CZRD ROUND

• Two-position 24V 1.2 VA 3-wire power open, power close actuator

• Constructed of galvanized smooth steel• Double beaded for rigidity• Offered in round diameters of 5”, 6”, 7”, 8”,

9”, 10”, 12”, 14”, 16”, 18”• Nylon bushings for quiet, long lasting

operation• Compatible with residential or light

commercial applications with static pressure less than 1.0” WC

Page 16: Fahrenheit Zone Control

CZRD™ Combination Zone Relief Damper CZRD Rectangular Side Mount

• Two-position 24V 1.2 VA 3-wire power open, power close actuator

• Constructed of durable extruded aluminum frame with a one piece galvanized steel blade

• Available in all standard sizes starting at 8”x 8” and increasing in two inch increments with custom sizes available

• When ordering a side mount rectangular damper: A” x B” dimensions will be Width (always the larger dimension) x Height (always the smaller dimension) and the actuator and mounting plate will always be mounted on the B dimension

• Nylon bushings for quiet, long lasting operation• Compatible with residential or light commercial applications

with static pressure less than 1.0” WC

Page 17: Fahrenheit Zone Control

CZRD™ Combination Zone Relief Damper CZRD Rectangular Bottom Mount

• Two-position 24V 1.5 VA 3-wire power open, power close actuator

• The Bottom Mount CZRD uses a low-profile, slimline actuator for mounting inside the duct

• Available in all standard sizes starting at 8”x 8” and increasing in two inch increments with custom sizes available

• When ordering a bottom mount CZRD rectangular damper: A” x B” dimensions will be the Width x Height and the mounting plate will always be mounted on the A dimension while the actuator will be inside the damper

• Compatible with residential or light commercial applications with static pressure less than 1.0” WC

Page 18: Fahrenheit Zone Control

Spring Return Dampers RZRD – Residential Zone Round Damper

Two Position – 24V – 10VA – 2-wire power close, spring return open – sizes 4” – 20”

RZQD – Residential Zone Quadrangle DamperTwo Position – 24V – 10VA – 2-wire power close, spring return open – sizes starting at 6”X6” increasing in 2” increments – custom sizes available

Page 19: Fahrenheit Zone Control

Retrofit DamperRFRD – Retrofit Round Damper • Two-position 24V 1.2 VA 3-wire power open, power close

actuator• Used for applications where ductwork is not easily

accessible• Urethane outer blade seal ensures a tight seal• Offered in round diameters of 5”, 6”, 7”, 8”, 9”, 10”

Page 20: Fahrenheit Zone Control

Barometric Bypass DampersBBRD – Barometric Bypass Round Damper• Uses an easily adjustable weighted arm• Replacement arms are available• Only used for a horizontal mounting orientation• Primarily used for residential applications with

static pressure up to 0.75” WC• Available sizes are 7”, 8”, 9”, 10”, 12”, 14”, 16”

BBVRD – Barometric Bypass Vertical Round Damper• Uses an easily adjustable weighted arm• Replacement arms are available• Only used for a vertical mounting orientation• Primarily used for residential applications with static

pressure up to 0.75” WC• Available sizes are 10” and 12” only

Page 21: Fahrenheit Zone Control

Electric Bypass DampersEBRD – Electric Bypass Round DamperControlled by a floating point 24 VAC 2 VA 3-wire power open, power close actuator and a Static Pressure Sensor (SPS) factory set at 0.45” WCPrimarily used for light commercial applications with units 7.5 tons and larger and static pressure from 0.08” to 1.25” WC

EBQD – Electric Bypass Quadrangle DamperControlled by a floating point 24 VAC 2 VA 3-wire power open, power close actuator and a Static Pressure Sensor (SPS) factory set at 0.45” WCPrimarily used for light commercial applications with units 7.5 tons and larger and static pressure from 0.08” to 1.25” WC

Page 22: Fahrenheit Zone Control

Stand Alone DampersMMRD – Master Modulating Round Damper• Comes with a thermo-sensor and actuator PC

Board• Floating point 24V 2 VA 3-wire power open, power

close high torque actuator• Primarily for light commercial applications with

static pressure up to 2” WC• Nylon bushings for quiet, long lasting operation• Constructed of galvanized smooth steel, double

beaded for rigidity• Offered in round diameters of 6”, 7”, 8”, 9”, 10”,

12”, 14”, 16”, 18”, 20”

Page 23: Fahrenheit Zone Control

Stand Alone DampersMMQD – Master Modulating Quadrangle Damper• Comes with a thermo-sensor and actuator PC Board• Floating point 24V 2 VA 3-wire power open, power close high torque

actuator• Primarily for light commercial applications with static pressure up to

2” WC• Available in all standard sizes starting at 8”x8” and increasing in two

inch increments with custom sizes available• When ordering a side mount rectangular damper: A” x B” dimensions

will be Width (always the larger dimension) x Height (always the smaller dimension) and the actuator and mounting plate will always be mounted on the B dimension unless the dimensions are a square in which case there is no need to specify side or bottom mount

• When ordering a bottom mount rectangular damper: A” x B” dimensions will be Width (always the larger dimension) x Height (always the smaller dimension) and the actuator and mounting plate will always be mounted on the A dimension

Page 24: Fahrenheit Zone Control

Modulating DampersMRD – Modulating Round Damper• Floating point 24V 2 VA 3-wire

power open, power close high torque actuator

• Primarily for light commercial applications with static pressure up to 2” WC

• Nylon bushings for quiet, long lasting operation

• Constructed of galvanized smooth steel, double beaded for rigidity

• Offered in round diameters of 6”, 7”, 8”, 9”, 10”, 12”, 14”, 16”, 18”, 20”

.

Page 25: Fahrenheit Zone Control

Modulating DampersMQD – Modulating Quadrangle Damper• Floating point 24V 2 VA 3-wire power open, power close high

torque actuator• Primarily for light commercial applications with static pressure

up to 2” WC• Available in all standard sizes starting at 8”x8” and increasing

in two inch increments with custom sizes available• When ordering a side mount rectangular damper: A” x B”

dimensions will be Width (always the larger dimension) x Height (always the smaller dimension) and the actuator and mounting plate will always be mounted on the B dimension unless the dimensions are a square in which case there is no need to specify side or bottom mount

• When ordering a bottom mount rectangular damper: A” x B” dimensions will be Width (always the larger dimension) x Height (always the smaller dimension) and the actuator and mounting plate will always be mounted on the A dimension

Page 26: Fahrenheit Zone Control

ThermostatsThermostats for every applicationThe Fahrenheit Series carries a wide range of Braeburn thermostats for every possible application. Thermostats will control the temperature in each zone of a building. Every zone needs one thermostat and programmable thermostats are always suggested when installing a Zone Control System because of their added control and energy savings.

Programmable

Non - Programmable

Page 27: Fahrenheit Zone Control

Fresh Air Ventilation SystemFAVS – Fresh Air Ventilation SystemThe Fahrenheit series also offers a simple way to control the indoor air quality (IAQ) of a home. Our Fresh Air Ventilation System (FAVS) is incredibly easy to install and set in order to achieve adequate fresh air throughout a home. As more and more homes are built “tighter” it is becoming very important to ventilate homes during the months that windows and doors cannot be opened. Even more important is the trend of states passing legislation requiring homes to have systems that introduce fresh air into a home. FAVS is ASHRAE 62.2 standard compliant. 

The FAVS kit comes with either a 6” or 8” round damper that is factory set to be powered open, spring return closed, a control panel, and a transformer.

These items can be sold separately.

Page 28: Fahrenheit Zone Control

Fresh Air Ventilation System

FAVS – Fresh Air Ventilation System• Low cost solution to improve IAQ• Status LEDs• One-time adjustment setup• Override switch to close the damper• Meets ASHRAE Standard 62.2• 5 year warranty

Page 29: Fahrenheit Zone Control

Questions.

Page 30: Fahrenheit Zone Control

Contact InformationKurt Wessling

Sales Manager

[email protected]

727.457.7996 mobile727.441.2657 direct727.431.6197 office

www.fahrenheitseries.com