Kapitel 1 _ Einleitung_eng

Embed Size (px)

Citation preview

  • 8/3/2019 Kapitel 1 _ Einleitung_eng

    1/12

    Sie

    mensIndustrialServices

    Industrial Solutions and Services

    Your Success is Our Goal

    Workshop S7 400 H

    Introduction

    I&S IS E&C PS2, H&F Competence Center, Schreiberhauer Str. 3; 90475 Nrnberg

  • 8/3/2019 Kapitel 1 _ Einleitung_eng

    2/12

    Sie

    mensIndustrialServices

    Industrial Solutions and Services

    Your Success is Our Goal

    Contact:

    I&S IS E&C PS2

    Center of Competence H&F

    +49 (911) 895 4759

    [email protected].

  • 8/3/2019 Kapitel 1 _ Einleitung_eng

    3/12

    SIMATIC Fault-Tolerant-SystemsPage 3

    Industrial Solutions and Services Your Success is Our Goal

    Overview of the Workshop

    H&F Competence Center

    Safety of machinery

    The highly available operating system

    Programming

    Peripheral Devices

    Projection

    System-State-List

    Component Failure/Replacement

    Communication

    Online System Changes (RUN)

    Overview of theworkshop

    The H&F CC

    Resorts

    Contact

    References

    .........

  • 8/3/2019 Kapitel 1 _ Einleitung_eng

    4/12

    SIMATIC Fault-Tolerant-SystemsPage 4

    Industrial Solutions and Services Your Success is Our Goal

    fault-tolerant and failsafe programmable controllers.

    We provide you with worldwide support in your applications for

    Competence Center For H&F Systems

    S5-155H

    S5-115H

    S5-95F

    S5-115F

    S7-400H

    S7-300 / S7-400Softwareredundanz

    S7-400F/FH

    S7-300F

    Overview of theworkshop

    The H&F CC

    Resorts

    Contact

    References

    .........

  • 8/3/2019 Kapitel 1 _ Einleitung_eng

    5/12

    SIMATIC Fault-Tolerant-SystemsPage 5

    Industrial Solutions and Services Your Success is Our Goal

    Project supportProject support

    We can help and support you to design and to commissioning yoursafety-related application.

    Our engineers and specialists are available to answer all your questionson safety engineering.

    OnOn--site servicesite service

    Specially trained members of the H&F team are on stand-by to deal with anymalfunctions in your H&F-SIMATIC systems - worldwide!

    Services Of The Center Of Competence

    Overview of theworkshop

    The H&F CC

    Resorts

    Contact

    References

    .........

  • 8/3/2019 Kapitel 1 _ Einleitung_eng

    6/12

    SIMATIC Fault-Tolerant-SystemsPage 6

    Industrial Solutions and Services Your Success is Our Goal

    Workshops

    Workshops for H&F systems are hosted by our experienced staff and canbe adapted to address your special plant conditions.If you prefer, we can come to you!

    H&F CC Your competent contact for anyH&F CC Your competent contact for any

    safety engineering problem!safety engineering problem!

    Services Of The Center of Competence

    Overview of theworkshop

    The H&F CC

    Resorts

    Contact

    References

    .........

  • 8/3/2019 Kapitel 1 _ Einleitung_eng

    7/12

    SIMATIC Fault-Tolerant-SystemsPage 7

    Industrial Solutions and Services Your Success is Our Goal

    Contacts

    Overview of theworkshop

    The H&F CC

    Resorts

    Contact

    References

    .........

    H&F Competence CenterH&F Competence Center

    I&S IS E&C PS2

    Tel.: +49 911 895 4759

    mailto:[email protected]

    SIMATIC Customer Support:SIMATIC Customer Support:

    A&D AS CS1

    Tel.: +049 180 5050222

    Fax.: +049 180 5050223

    mailto: [email protected]

    http://www.ad.siemens.de/support

  • 8/3/2019 Kapitel 1 _ Einleitung_eng

    8/12

    SIMATIC Fault-Tolerant-SystemsPage 8

    Industrial Solutions and Services Your Success is Our Goal

    Huldra Project (Norway)

    Oil Rig Emergency Shut-Down and Fire and Gas Protection System

    5 S7-400 F and FH stations with more than

    50 ET 200M stations

    Approx. 3000 fail-safe I/Os

    Services of the Center of Competence Safety Integrated:

    Support during plant configuration

    Support during commissioning of the fail-safe components and optimization of the

    plant on-site by a employee of the CoC

    1-2 employee of CoC SI permanently on-site in the winter of 1999/2000

    Overview of theworkshop

    The H&F CC

    Resorts

    Contact

    References

    .........

  • 8/3/2019 Kapitel 1 _ Einleitung_eng

    9/12

    SIMATIC Fault-Tolerant-SystemsPage 9

    Industrial Solutions and Services Your Success is Our Goal

    FailFail--safe communication ofsafe communication ofthe S7the S7--400F systems by radio400F systems by radio

    Huldra Project (Norway)

    Overview of theworkshop

    The H&F CC

    Resorts

    Contact

    References

    .........

  • 8/3/2019 Kapitel 1 _ Einleitung_eng

    10/12

    SIMATIC Fault-Tolerant-SystemsPage 10

    Industrial Solutions and Services Your Success is Our Goal

    Fail-safe, Redundant System for Burner management and Boiler Protektion

    - Support during plant configuration

    - Training the operational staff by CoC lokally (Supervising)

    - 4 S7-400 FH stations

    - approx. 400 fail-safe I/Os

    Services of Competence Center Safety Integrated

    - Feb 06 / Oct 06:

    Support during commissioning the components on site by two

    employees of CoC

    Mindanao Project (Philippines)

    - approx. 200 standard I/Os

    Overview of theworkshop

    The H&F CC

    Resorts

    Contact

    References

    .........

  • 8/3/2019 Kapitel 1 _ Einleitung_eng

    11/12

    SIMATIC Fault-Tolerant-Systems Page 11

    Industrial Solutions and Services Your Success is Our Goal

    Oseberg Project Norway

    Offshore-projectabout 130 kilometersaway from the coast

    108 SIMATIC 417F/HFwith 38.000 I/Os

    Upgrade of Teleperm M and SIMATICS5 to SIMATIC PCS 7 in 3phases while fully production.

    1. Changing the display panels2. Installation Ethernet network

    3. Replace the steering systems

    Overview of theworkshop

    The H&F CC

    Resorts

    Contact

    References

    .........

  • 8/3/2019 Kapitel 1 _ Einleitung_eng

    12/12

    SIMATIC Fault-Tolerant-Systems Page 12

    Industrial Solutions and Services Your Success is Our Goal

    Fault-Tolerant-Systems