Transcript
Page 1: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Technisches Handbuch / Technical Manual

Mainboard D1501Deutsch / English

2

Page 2: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Sie haben ...

... technische Fragen oder Probleme?

Wenden Sie sich bitte an:• Ihren zuständigen Vertriebspartner• Ihre Verkaufsstelle

Weitere Informationen finden Sie im Handbuch "Sicherheit" und "Ergonomie".

Aktuelle Informationen und Updates (z. B. BIOS-Update) zu unseren Mainboards finden Sie imInternet: http://www.fujitsu-siemens.com/mainboards

Are there ...

... any technical problems or other questions you need clarified?

Please contact:• your sales partner• your sales outlet

You will find further information in the manuals "Safety" and "Ergonomics".

The latest information and updates (e. g. BIOS update) on our mainboards can be found on theInternet under: http://www.fujitsu-siemens.com/mainboards

Page 3: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe
Page 4: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Dieses Handbuch wurde auf Recycling-Papier gedruckt.This manual has been printed on recycled paper.Ce manuel est imprimé sur du papier recyclé.Este manual ha sido impreso sobre papel reciclado.Questo manuale è stato stampato su carta da riciclaggio.Denna handbok är tryckt på recyclingpapper.Dit handboek werd op recycling-papier gedrukt.

Herausgegeben von/Published byFujitsu Siemens Computers GmbH

Bestell-Nr./Order No.: A26361-D1501-Z120-1-7419Printed in the Federal Republic of GermanyAG 0203 02/03

A26361-D1501-Z120-1-7419

Mainboard D1501 TECHNISCHES HANDBUCHTECHNICAL MANUAL

Page 5: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Mainboard D1501

Technisches HandbuchTechnical Manual

Deutsch

English

Ausgabe Februar 2003February 2003 edition

Page 6: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Intel, Pentium und Celeron sind eingetragene Warenzeichen der Intel Corporation, USA.

Microsoft, MS, MS-DOS und Windows sind eingetragene Warenzeichen der MicrosoftCorporation.

PS/2 und OS/2 Warp sind eingetragene Warenzeichen von International Business Machines,Inc.

Alle weiteren genannten Warenzeichen sind Warenzeichen oder eingetragene Warenzeichender jeweiligen Inhaber und werden als geschützt anerkannt.

Copyright � Fujitsu Siemens Computers GmbH 2003

Alle Rechte vorbehalten, insbesondere (auch auszugsweise) die der Übersetzung, desNachdrucks, der Wiedergabe durch Kopieren oder ähnliche Verfahren.

Zuwiderhandlungen verpflichten zu Schadenersatz.

Alle Rechte vorbehalten, insbesondere für den Fall der Patenterteilung oder GM-Eintragung.

Liefermöglichkeiten und technische Änderungen vorbehalten.

Dieses Handbuch wurde erstellt voncognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Intel, Pentium and Celeron are registered trademarks of Intel Corporation, USA.

Microsoft, MS, MS-DOS and Windows are registered trademarks of Microsoft Corporation.

PS/2 and OS/2 Warp are registered trademarks of International Business Machines, Inc.

All other trademarks referenced are trademarks or registered trademarks of their respectiveowners, whose protected rights are acknowledged.

All rights, including rights of translation, reproduction by printing, copying or similar methods,even of parts are reserved.

Offenders will be liable for damages.

All rights, including rights created by patent grant or registration of a utility model or design,are reserved. Delivery subject to availability.

Right of technical modification reserved.

This manual was produced bycognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Page 7: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

A26361-D1501-Z120-2-7419

ContentsIntroduction........................................................................................................................................1

Notational conventions ..............................................................................................................1Important notes..................................................................................................................................1

Information about boards ...........................................................................................................2Features ............................................................................................................................................3

External ports ............................................................................................................................5Baseboard management controller ............................................................................................5Internal ports and connectors ....................................................................................................6Temperature / System monitoring..............................................................................................7IDE connector............................................................................................................................8LAN connector...........................................................................................................................8PCI bus interrupts ......................................................................................................................9SCSI/HostRAID configuration programme .................................................................................9SCSI Disk Utilities....................................................................................................................16

Jumper settings ...............................................................................................................................17Clear CMOS RAM - JP 14 .......................................................................................................17Boot Block - JP 15 ...................................................................................................................17BMC Power On Control - JP 16 ...............................................................................................17

Add-on modules ..............................................................................................................................18Installing the processor with heat sink and fan.........................................................................19Upgrading main memory..........................................................................................................21Replacing lithium battery..........................................................................................................22

Glossary ..........................................................................................................................................23

Page 8: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe
Page 9: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

A26361-D1501-Z120-2-7419 English - 1

IntroductionThis technical manual describes the mainboard D1501.

You will find further information in the "BIOS Setup" description.

Further information about drivers is provided in the readme files on the hard disk, on the supplieddrivers diskettes, on the "Drivers & Utilities" or on the "ServerStart" CD.

Notational conventionsThe meanings of the symbols and fonts used in this manual are as follows:

! Pay particular attention to text marked with this symbol. Failure to observe this warningendangers your life, destroys the device, or may lead to loss of data.

i Supplementary information, remarks, and tips follow this symbol.

Ê Text which follows this symbol describes activities that must be performed in the order shown.

Ë This symbol indicates that you must enter a blank space (press the Space Bar) at this point.

Ú This symbol indicates that you must press the Enter key.

Text in this typeface indicates screen outputs.

Text in this bold typeface indicates the entries you make via the keyboard.

Text in italics indicates commands or menu items.

"Quotation marks" indicate names of chapters or terms.

Important notesWith the mainboard installed you must open the system to access the mainboard. How to dismantleand reassemble the system is described in the operating manual accompanying the system.

Connecting cables for peripherals must be adequately shielded to avoid interference.

! Observe the safety notes in the operating manual of your system.

Incorrect replacement of the lithium battery may lead to a risk of explosion. It is thereforeessential to observe the instructions in the "Add-on modules" - "Replacing lithium battery"section.

Components can become very hot during operation. Ensure you do not touchcomponents when making extensions to the mainboard. There is a danger of burns!

Connecting cables for peripherals must be adequately shielded to avoid interference.

The shipped version of this board complies with the requirements of the EEC directive89/336/EEC "Electromagnetic compatibility".

Compliance was tested in a typical PC configuration.

When installing the board, refer to the specific installation information in the manual forthe receiving device.

Page 10: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Important notes

2 - English A26361-D1501-Z120-2-7419

iThe warranty is invalidated if the system is damaged during the installation orreplacement of expansions. Information on which expansions you can use is availablefrom your sales outlet or the customer service centre.

Information about boardsTo prevent damage to the mainboard, the components and conductors on it, please take great carewhen you insert or remove boards. Take great care to ensure that extension boards are slotted instraight, without damaging components or conductors on the mainboard, or any other components,for example EMI spring contacts.

Remove the plug from the mains outlet so that system and mainboard are totally disconnected fromthe mains voltage.

Be careful with the locking mechanisms (catches, centring pins etc.) when you replace themainboard or components on it, for example memory modules or processors.

Never use sharp objects (screwdrivers) for leverage.

Boards with electrostatic sensitive devices (ESD) are identifiable by the label shown.

When you handle boards fitted with ESDs, you must, under all circumstances,observe the following:

• You must always discharge static build up (e.g. by touching a grounded object)before working.

• The equipment and tools you use must be free of static charges.

• Remove the power plug from the mains supply before inserting or removingboards containing ESDs.

• Always hold boards with ESDs by their edges.

• Never touch pins or conductors on boards fitted with ESDs.

Page 11: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

A26361-D1501-Z120-2-7419 English - 3

FeaturesMainboard in ATX format (305 mm x 244 mm)

Processor socket for Intel Pentium 4 or Celeron from 2.4 GHz and with 533 MHz System Bus512 Kbyte on-die cache

• Intel processor Pentium 4 with 533 MHz Front Side Bus. The size and clock frequency of first-level cache and second-level cache are dependent upon the processor used.

• Chipset: ServerWorks GC-SL (Grand Champion-SL) and CSB6

4 DIMM slots for DDR-RAM-memory modules 266 MHz with ECC; at least 256 Mbyte, a maximumof 4 Gbyte memory configuration possible

• four 64 bit PCI slots with 33 MHz

• one 32 bit PCI slot with 33 MHz

special PCI slot for Zero Channel RAID Controller (the onboard SCSI controller AIC 7901 is used bythe ZCR-Controller)

SCSI controller AIC7901 One-Channel, Ultra 320 capable

Host RAID implemented with SCSI-Controller. The RAID levels 0,1 and 10 are supported.

Video-Controller ATI Rage XL with 8 Mbyte SDRAM

Gigabit LAN controller, Intel 82540EM (10/100/1000 MBit/s)

IDE hard disk controller connected to PCI bus for up to two IDE hard disksmode capable, supports PIO modes 3 and 4

• Floppy disk drive controller (possible formats: 720 Kbyte, 1.44 Mbyte)

• Flash BIOS

• system monitoring

− System monitoring and temperature monitoring− Error log in EEPROM− SMBus (Server Management)− RSB (Remote Service Board)− Redundant power supply monitoring

• Power-on functions:

− Wake on RTCWake on LAN (LAN onboard)− Wake on PCI Cards (LAN)− COM1 wake up support (standby / soft-off)

• Security functions:

− Processor serial number− Cover monitoring: cover monitoring reports when the cover has been opened without

authorisation.System, Setup and Keyboard password− parallel and serial ports can be deactivated− Floppy disk write-protection via BIOS Setup− Boot hard disk virus warning function

Page 12: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

4 - English A26361-D1501-Z120-2-7419

• Real-time clock/calendar with integrated battery backup

• 1 internal USB port

• 1 external parallel port (ECP- and EPP-compatible)

• two external serial ports (COM1 and COM2)

• two external USB ports (USB = Universal Serial Bus)

• 1 LAN connector (RJ45)

• 1 VGA port

• two external PS/2 ports for keyboard and mouse

Page 13: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

A26361-D1501-Z120-2-7419 English - 5

External ports

2 5

1 6

7

8

9

103

4

1 = Health-LED: orange2 = ID-LED: blue3 = PS/2 mouse port4 = PS/2 keyboard port5 = Serial interface 1 (COM1)

6 = Parallel port7 = Serial interface 2 (COM2)8 = LAN connector9 = USB ports A and B10 = VGA port

Baseboard management controller

• format 60 x 50 mm

• Interrupt-Controller Chipset: Winbond W83910F and W24100S

• EEPROM 2 Mbyte (Winbond W39F010P)

• 80-pin connector

• quartz frequency: 40,000 MHz and 32,768 KHz

• Installing on the mainboard (2 screws M2x5 mm)

Page 14: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

6 - English A26361-D1501-Z120-2-7419

Internal ports and connectors

1 2 3 4 5 6 7 10 11

1213

14

16

17

18

8 9

15

PCI 2

PCI 3

PCI 1

PCI 4

PCI 5

DIM

M 1

DIM

M 2

DIM

M 3

DIM

M 4

19

20

1 = SMBTerm2 = USB ports3 = Power supply monitoring4 = Power supply ATX5 = Floppy Disk Drive6 = IDE drives 1 and 2 (primary)7 = IDE drives 3 and 4 (secondary)8 = IPMB9 = SMB 110 = JP16

11 = Cover monitoring12 = JP1513 = SCSI connection14 = Connector for front panel15 = VCC_RSB (Remote Service Board)16 = Buzzer17 = System fan18 = Power supply +12 V (for processor)19 = Processor fan20 = JP14

Page 15: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

A26361-D1501-Z120-2-7419 English - 7

Temperature / System monitoringTemperature and system monitoring aim to reliably protect the computer hardware against damagecaused by overheating. However, unnecessary noise is prevented with a fan speed adapted to thetemperature conditions. In addition, important information on the operating state of the device(temperature, operating voltate, fan speeds, error states) is provided. The cover monitoring systemindicates an unauthorized opening of the device.

These functions are controlled by the Baseboard management controller.

The following functions are supported:

Temperature monitoring:

Measurement of the processor temperature, measurement of the air temperature upon entry with atemperature sensor.

Temperature control:

The fan speed of the system fan is controlled depending on the air temperature upon entry. When aspecified temperature limit is exceeded, the processor clock frequency is also reduced (throttlingmode) to prevent further warming of and damage to the processor.

Fan monitoring:

Blocked fans or a reduced fan speed due to ageing can be detected with the fan monitoringfunction. Blocked fans are operated with 12 V pulse voltage. An attempt is made to restart a blockedsystem fan with a cyclical voltage pulse. If the system fan is removed with the device switched off,this results in an error message when the device is switched on again. This is indicated optically bythe flashing of the system error LED on the control panel. In addition, an entry is generated in theBIOS Error Log.

Fan control:

The system fan and power supply fan are controlled in dependence on the temperature.

When exceeding predefined temperature threshold the fanmotors in the power supply modules areaccelerated to maximale rotational speed.

Sensor monitoring:

The installed sensors are also monitored. If a sensor outputs an impermissible value, this results inan increase in the fan speed to the maximum value in order to ensure the maximum possibleprotection of the hardware.

A failed sensor results in an error message. This is indicated optically by the flashing of the HealthLED on the control panel. In addition, an entry is generated in the BIOS Error Log.

Cover monitoring:

Unauthorised opening of the cover is detected, even when the system is switched off. However, thiswill only be indicated when the system is switched on again.

This procedure generates an entry in the BIOS Error Log.

Page 16: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

8 - English A26361-D1501-Z120-2-7419

Voltage monitoring:

The operating voltages +5 V, +12 V, 3,3 V, 5 V the auxiliary voltage, the CPU core voltage and theCMOS-battery are monitored.

If the voltage lies outside the specified tolerances, an error message is generated. This is indicatedoptically by the flashing of the Health LED on the control panel. In addition, an entry is generated inthe BIOS Error Log.

Advantages of hardware system monitoring

With hardware monitoring - regardless of the operating system and processor - the advantagescompared to conventional software monitoring are clear:

− suitable for all operating systems and processor types

− no additional load on processor (performance)

− optimum temperature protection, even if process faults or faults are present in theoperating system

− optimum noise reduction

IDE connectorÊ The system is equipped with two independent ATA/100 interfaces.

The Chip disk is always to be connected on the Primary IDE connector.

The CD-ROM/DVD/CD-RW drive is to be connected on the Secondary IDE connector.

LAN connectorThis mainboard has an Intel gigabit LAN controller ( This LAN controller supports the transfer ratesof 10 Mbit/s, 100 Mbit/s and 1 Gbit/s. The LAN controller is equipped with a 3 KB transmission andreceiving buffer (FIFO) and supports WOL function through Magic Packet�.

In addition, Bootix LAN BootP and Intel PXE are also supported (support of systems without harddisks).

Basic AOL II is also supported. Basic AOL II helps to protect systems against theft or damage.Basic AOL II can also inform the administrator about hardware faults and software errors.

The LAN RJ45 connector is equipped with a yellow and a green LED (light emitting diode).

12

1 = Yellow indicator. a connection exists (e.g.to a hub).

2 = Green indicator:Link Mode: the LAN connection is active.WOL mode: a Magic PacketTM is beingreceived.

Page 17: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

A26361-D1501-Z120-2-7419 English - 9

PCI bus interruptsThe following table shows which PCI bus interrupts are assigned on the mainboard.

Component on mainboard: PCI bus interruptPCI Slot 1 PCI_IRQ#7

PCI_IRQ#8PCI Slot 2 PCI_IRQ#3

PCI_IRQ#4PCI Slot 3 PCI_IRQ#5

PCI_IRQ#6PCI Slot 4 PCI_IRQ#1

PCI_IRQ#2PCI Slot 5 PCI_IRQ#7

PCI_IRQ#8LAN controller 82540 PCI_IRQ#12

VGA-Rage XL PCI_IRQ#11Onboard SCSI PCI_IRQ#0

SCSI/HostRAID configuration programmeThe BIOS of the Onboard U320 SCSI controller includes a menu-driven SCSI/HostRAIDconfiguration programme. This programme allows you to change almost all of the option settings ofthe SCSI controller.

When you boot the system a SCSI/HostRAID-BIOS message listing the SCSI devices connected isdisplayed.

iIf an SCSI-BIOS error message appears or problems arise with SCSI devices, pleaseread the documentation of your SCSI device.

If you are unable to trace or rectify the error, please contact your dealer or our customerservice centre.

Working with the keyboard

Use the following keys when running the programme:

ËÊ to select an entry

Ú to accept a selection

[ESC] to call the previous menu and to terminate the SCSI configuration programme.

[F6] to reset to the default settings. This function is not possible in all menus.

Starting the SCSI/HostRAID configuration programme

Ê Start the PC, if the following message appears, press the key combination [Ctrl] and [A] :

Press <Ctrl> <A> for SCSI Select (TM) Utility!

In the first menu the available U320 SCSI Controller are displayed. The onboard SCSI controller ofD1501 is displayed with the following entry:

AIC-7901 at slot 00 00:04:00

Page 18: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

10 - English A26361-D1501-Z120-2-7419

When choosing the AIC-7901 you are taken to the top level of the configuration menu of thiscontroller. The following options cannot be displayed.

HostRAID is disabled (default):

Configure/View SCSI Controller Settings

SCSI Disk Utilities

Enable HostRAID Support

HostRAID is enabled:

Configure/View SCSI Controller Settings

Configure/View HostRAID Settings

SCSI Disk Utilities

Disable HostRAID Support

Terminating the SCSI configuration programme

Depending on the current menu level, you can display the previous menu by pressing the [ESC]key. If you have made changes in the current menu you will be prompted to store them.

Ê To quit the Configuration programme press the [ESC] key until a corresponding message isdisplayed. Select Yes to quit.

Ê

Activating and Configurating Host RAID

To configurate HostRAID select the menu entry Configure/View HostRAID Settings. If this entry isnot displayed you have to activate HostRAID with the entry Enable HostRAID Support.

Now the exsisting SCSI hard disks and alrady configurated RAID drives are displayed.

Select one of the displayed hard diks and configure the RAID-System to your needs.

iDetailed instruction on the configuration of HostRAID are contained in the HostRAIDUser's Guide.

The administration of the RAID system can be set later by a tool in your operating system(see therefor the documentation "Storage Manager Browser Edition"). this tool currently isavailable for Windows NT4 and Windows 2000.

Page 19: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

A26361-D1501-Z120-2-7419 English - 11

Default Settings in the menu Configure/View SCSI Controller Settings

SCSI Bus Interface Definitions Default setting

SCSI Controller ID 7

SCSI Controller Parity Enabled

SCSI Controller Termination Enabled

Additional Options Default setting

Boot Device Configuration Press <Enter>

Single Image

Master SCSI Controller AIC-7901 at slot 0000:04:00

Select SCSI peripheral from which to boot

Boot SCSI Controller AIC-7901 at slot 0000:04:00

Boot SCSI ID 0

Boot LUN number* 0

SCSI Device Configuration Press <Enter>

Sync Transfer Rate (MB/Sec) 320

Packetized Yes

QAS Yes

Initiate wide negotiation Yes (Enabled)

Enable disconnection Yes (Enabled)

Send Start Unit Command**** Yes

BIOS Multiple LUN Support No

Include in BIOS Scan Yes

Advanced Configuration Press <Enter>

Reset SCSI Bus at IC Initialization Enabled

Display <Ctrl><A> Message During BIOS Initialization Enabled

Extended Int 13 Translation for DOS Drives > 1Gbyte Enabled

POST Display Mode Verbose

SCSI Controller Int 13 Support Enabled

Domain Validation**** Enabled

Support Removable Disks Under Int 13asFixed Disks****

Disabled

BIOS Support for Bootable CD-ROM**** Enabled

* The setting is valid only if Multiple LUN Support is enabled (Enabled).**** The setting is valid only if the Int 13 Supportof the SCSI controller is enabled (Enabled).

Page 20: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

12 - English A26361-D1501-Z120-2-7419

SCSI Bus Interface Definitions

SCSI Controller ID

All SCSI devices on one SCSI bus, including the SCSI controller, must be set to separate SCSIaddresses.

The SCSI controller is normally set to ID 7.

You do not normally need to change the SCSI address, not even if you install several SCSIcontrollers. In this case each SCSI controller may be assigned address 7, because each isconnected to it’s own SCSI bus.

SCSI Controller Parity

The U320-SCSI controller uses parity bits on the SCSI bus to verify the data transfer from yourSCSI bus (Enabled).

If one of your SCSI devices does not support Parity Checking, disable it on the SCSI controller.

SCSI Controller Termination

The terminating resistors of the SCSI controller must be enabled.

! The default setting is Enabled. The terminating resistor of the SCSI controller is enabled.With [F6] you can reset to the default setting.

Additional Options

Master SCSI Controller

These settings display from which of the available SCSI controller the BIOS is loaded. As long asthe onboard SCSI controller AIC-7901 is activated, only this one is the master controller.

Boot SCSI Controller

This setting defines from which of the available SCSI controller is booted.

Boot Target ID

The U320-SCSI controller can start the operating system from a drive with any SCSI address (ID).The default setting is SCSI ID 0. The SCSI ID selected here must correspond to the ID configuredon the boot device.

Boot LUN number

If your boot device has multiple LUNs (Logical Unit Numbers) and Multiple LUN Support is Enabled,this option allows you to specify which LUN to boot from on your boot device. The default setting isLUN 0.

Page 21: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

A26361-D1501-Z120-2-7419 English - 13

SCSI Device Configuration

Sync Transfer Rate

Fast SCSI devices, including the U320-SCSI controller, are capable of transferring data to and fromthe SCSI bus at speeds ranging up to 320 Mbyte/s at synchronous data transfer. The configurablemaximum data transfer rate is 320 Mbyte/s. For this setting the options "Wide Negotiatin","Packatized" and "Disconnection" must be activated (YES).

Packetized

When activating the packetized option for the U320 SCSI operation not only data but also SCSIcommands and messages in synchronous operation are transferred. They are transferred togetherwith data in packages. With this more bus bandwidth for real data transmission are available. Thisoption is only for the U320 operation.

QAS

By the QAS (Quick Arbitration and Select) option the packages are transferred on the SCSI buswithout a bus free phase between the packages. As a result a higher throughput on the SCSI bus isachieved. This option is only for the U320 operation.

Initiate wide negotiation

This option determines whether the SCSI controller attempts 16-bit data transfer (Wide negotiation)instead of 8-bit data transfer. As a result two byte are transferred simultaneously via the SCSI businstead of one byte.

Enable disconnection

The default setting is Yes (enabled).

This permits SCSI devices to enable the SCSI bus during command execution.

A typical example of this is a tape device that has no need to access the SCSI bus during rewindingand can be "disconnected" from the SCSI bus for this period.

You can disable the function (No) if you have only connected one SCSI device. In this case,disabling disconnection improves performance slightly.

Send Start Unit Command

The default setting is Yes (enabled).

When this feature is enabled, the SCSI devices which support this function are not started byswitching on the server until they receive a "Start Unit" command from BIOS of the U320 SCSIcontroller. (To do this the U320-SCSI controller BIOS must not be disabled).

This function ist used to distribute the high starting currents of the SCSI devices over a specificperiod and to release the power supply of your server.

BIOS Multiple LUN Support

This option determines whether booting from a SCSI device that has multiple LUNs (Logical UnitNumbers) is supported. The default setting is No (disabled).

Page 22: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

14 - English A26361-D1501-Z120-2-7419

Include in BIOS Scan

With this setting it can be determined for every SCSI address on this SCSI bus, whether the SCSIBIOS while initialisating checkes or not that a SCSI device with this special address is connected tothe bus. The default setting is Yes, i.e. the corresponding SCSI address is checked.

Advanced Configuration Options

Reset SCSI Bus at IC Initialization

The default setting is Enabled.

This causes a reset on the SCSI bus during the initialisation of the SCSI controller. All the devicesconnected to the SCSI bus are reset and re-initialised by that.

Display <CTRL><A> Message During BIOS Initialization

This option determines whether the

Press <Ctrl> <A> for SCSISelect (TM) Utility!

message appears on your screen during system startup. The default setting is Enabled.

If this setting is disabled, you can still invoke the SCSI configuration programme by pressing [CTRL]and [A] at system bootup.

Extended Int 13 Translation for DOS Drives > 1Gbyte

The default setting is Enabled.

Normally, only drives with a capacity of up to 1 Gbyte can be accessed.

Enabling this option allows drives of up to 8 Gbyte capacity (2 Gbyte/partition) to be supportedunder MS-DOS 5.0 or higher.

The SCSI controller BIOS must be enabled. The drive must be controlled by the SCSI controllerBIOS.

iBack up the data on your large capacity drive before enabling the option.

After enabling this option, the drive must be re-partitioned and high-levelformatted with the DOS FDISK and FORMAT programmes.

Do not use this option with drives that contain two or more partitions formatted withdifferent operating systems.

POST Display Mode

The default setting is Verbose.

While the system is booting, the SCSI controller's BIOS reports which devices are connected to theSCSI bus. Further settings are Silent (no messages are shown) and Diagnostic (additionalinformation are shown for diagnostics purposes).

Page 23: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

A26361-D1501-Z120-2-7419 English - 15

SCSI Controller Int 13 Support

The default setting for the Int 13 SCSI controller´s support is Enabled. With this the SCSI controller´sBIOS is enabled.

If you are only running SCSI devices, from which you don´t want to boot and if you need space forthe BIOS of additional controller, then you disable the Int 13 support of the U320-SCSI-controller.

When you disable the Int 13 support via the SCSI configuration programme, you can retain accessto the configuration programme at system start-up with the [Ctrl] - [A] keys.

iNote under DOS that you will have to install additional drivers to access drives if the Int13 support of the U320-SCSI controller is disabled.

Domain Validation

The default setting is Enabled.

The SCSI controller checks with a short test, whether the transmission rate set under Sync TransferRate is possible. If errors occur, the transmission rate is reduced as far as no more errors occur.

Support Removable Disks under Int 13 as Fixed Disks

This option allows you to use removable-media drives, such as CD-ROM drives, without installingadditional drivers. The default setting is Disabled.

! If a removable-media device is controlled by the SCSI controller BIOS, do not remove themedia while the PC is on.

BIOS Support for Bootable CD-ROM

This option determines whether the BIOS supports a CD-ROM drive startup drive, i.e. you can bottfrom CD-ROM. The default setting is Enabled.

Page 24: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Features

16 - English A26361-D1501-Z120-2-7419

SCSI Disk UtilitiesWhen you select the SCSI Disk Utilities menu item, you are shown a list of all the devices connectedto the SCSI bus. You are also offered two menus for hard disk drives: Verify and Format Disk.

Verify

With Verify you can have a selected hard disk drive checked. All defects that are detected will beentered in the existing error list for the hard disk.

Format Disk

With Format Disk a selected hard disk is formatted in low-level format. Normally hard disks arealready formatted in low-level format. You should use this menu item only if you want to erase thehard disk completely and regenerate the error list.

Page 25: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Jumper settings

A26361-D1501-Z120-2-7419 English - 17

Jumper settings

1 3

The position of pin 1 in screen process of themainboard is highlighted bold.

i The clock frequency of the processor is set automatically.

Clear CMOS RAM - JP 14The jumper JP14 allows you to delete the CMOS RAM.

1-2 Normal operation: The CMOS RAM is connected with the lithium battery (defaultsetting).

2-3 The CMOS RAM is deleted.

Boot Block - JP 15The jumper JP15 enables recovery of the old system BIOS after an attempt to update has failed. Torestore the old system BIOS you need a Flash BIOS Diskette (please call our customer servicecentre).

1-2 The System is started with the system BIOS from the mainboard (default setting).

2-3 The system boots from the "Flash BIOS floppy disk" from Drive A and reprogramsthe system BIOS on the board.

BMC Power On Control - JP 16The jumper JP16 allows the selection, by which chip the system start up is initiated and controled.

1-2 Power-on/off can only be controlled by the Baseboard Management Controller(default setting).

2-3 Baseboard Management Controller and Super I/O (BMC) can control Power-on/off.

Page 26: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Add-on modules

18 - English A26361-D1501-Z120-2-7419

Add-on modules

! Exit the operating system and wait until the device has switched off. Pull the power plugout of the mains outlet!Even with the system switched off, certain parts of the device (e.g. memory modules andPCI expansion boards) may still be energised.

PCI 2

PCI 3

PCI 1

PCI 4

PCI 5

DIM

M 1

DIM

M 2

DIM

M 3

DIM

M 4

1

45

6

3

8

7

2

1 = Socket for processor with heat sink2 = Location bank 1 for main memory3 = Location bank 2 for main memory4 = Location bank 3 for main memory

5 = Location bank 4 for main memory6 = Baseboard management controller (BMC)7 = Lithium battery8 = PCI slots 1, 2, 3, 4, 5

The PCI slots 2-5 are supplied with 5 V main voltage, the PCI slot 1 with 3,3 V. PCI slot 1 supports aZero Channel RAID Controller.

PCI slot 4 supports RSB (RSB = Remote Service Board) with battery package.

PCI slot 5 supports RSB without battery package.

Page 27: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Add-on modules

A26361-D1501-Z120-2-7419 English - 19

Installing the processor with heat sink and fanÊ Remove the heat sink including the fan fixed upon it.

3 2

1

A

4 53 2

1

A

4 5

Ê Pull the lever in the direction of the arrow (1) and lift it as far as it will go (2).

Ê Remove the old processor from the socket (3).

Ê Insert the new processor in the socket so that the angled corner of the processor matches thecoding on the socket (A) with regard to the position (4).

Push the lever back down until it clicks into place (5).

Mounting heat sink

If you are installing the heat sink you must ensure a good heat contact between heat sink and theprocessor´s surface. It is essential to use heat conducting material between the processor and theheat sink.

If you remove the heat sink, you must clean it (e.g. with benzine) and apply new heat conductingpaste before you remount it.

Please note that, depending on the heat sink used, different heat sink mounts are required on themainboard.

iSince a counter-plate is mounted on the underside of the mainboard for reinforcement, noheat sinks of the type "Intel Boxed" may be used. Otherwise the retaining clips of the heatsink will be damaged.

Only use the supplied heat sink and the supplied retaining springs.

Page 28: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Add-on modules

20 - English A26361-D1501-Z120-2-7419

When using a new heat sink:

Ê Remove the protection cover from theunderside of the heat sink.

When using the previous heat sink:

Ê Apply an even coat of heat conducting pasteto the entire surface of the processor andmount the heat sink on it.

Ê Fix the heat sink with the supplied retainingsprings.

Page 29: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Add-on modules

A26361-D1501-Z120-2-7419 English - 21

Upgrading main memoryThe slots for the main memory are suitable for 256, 512, 1024 Mbyte unbuffered DDR-DIMMmemory modules.

Memory modules with different memory capacities can be combined.

! You may only use unbuffered 3.3V memory modules. Buffered memory modules are notallowed and lead to a device failure.

DIMM memory modules must meet the PC2100 specification.

Installing a memory module

2

2

Ê Push the holders on each side of the memory slot outwards.

Ê Push the memory module into the location (1).

Ê At the same time flip the both lateral holders upwards until the memory module snaps inplace (2).

Removing a memory module

1

1

Ê Push the clips on the right and left of the memory slot outward (1).

Pull the memory module out of the memory slot (2).

Page 30: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Add-on modules

22 - English A26361-D1501-Z120-2-7419

Replacing lithium batteryIn order to permanently save the system information, a lithium battery is installed to provide theCMOS-memory with a current. A corresponding error message notifies the user when the charge istoo low or the battery is empty. The lithium battery must then be replaced.

! Incorrect replacement of the lithium battery may lead to a risk of explosion!

The lithium battery may be replaced only with an identical battery or with a typerecommended by the manufacturer.

Do not throw lithium batteries into the household waste. They must be disposed of inaccordance with local regulations concerning special waste.

Make sure that you insert the battery the right way round. The plus pole must be on thetop!

The lithium battery holder exists in different designs that function in the same way.

2 3

31

2

3

Ê Press the locking lug in the direction of the arrow (1); the battery jumps somewhat out of theholder (2).

Ê Remove the battery (2).

Ê Insert a new lithium battery of the same type into the socket (3).

Page 31: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Glossary

A26361-D1501-Z120-2-7419 English - 23

GlossaryThe technical terms and abbreviations given below represent only a selection of the full list ofcommon technical terms and abbreviations.Not all technical terms and abbreviations listed here are valid for the described mainboard.

ACPI Advanced Configuration andPower Management Interface

ISA Industrial Standard Architecture

AC'97 Audio Codec '97 LAN Local Area NetworkAGP Accelerated Graphics Port LSA LAN Desk Service AgentAMR Audio Modem Riser MCH Memory Controller HubAOL Alert On LAN MMX MultiMedia eXtensionAPM Advanced Power Management P64H PCI64 HubATA Advanced Technology

AttachmentPCI Peripheral Component

InterconnectBIOS Basic Input Output System PXE Preboot eXecution EnvironmentCAN Controller Area Network RAM Random Access MemoryCPU Central Processing Unit RAMDAC Random Access Memory Digital

Analogue ConverterCNR Communication Network Riser RDRAM Rambus Dynamic Random

Access MemoryC-RIMM Continuity Rambus Inline

Memory ModuleRIMM Rambus Inline Memory Module

DIMM Dual Inline Memory Module RTC Real Time ClockECC Error Correcting Code SB SoundblasterEEPROM Electrical Erasable

Programmable Read OnlyMemory

SDRAM Synchronous Dynamic RandomAccess Memory

FDC Floppy disk controller SGRAM Synchronous Graphic RandomAccess Memory

FIFO First-In First-OutFSB Front Side Bus SIMD Streaming Mode Instruction

(Single Instruction Multiple Data)FWH Firmware Hub SMBus System Management BusGMCH Graphics and Memory Controller

HubSVGA Super Video Graphic Adapter

GPA Graphics PerformanceAccelerator

USB Universal Serial Bus

I2C Inter Integrated Circuit VGA Video Graphic AdapterIAPC Instantly Available Power

Managed Desktop PC DesignWOL Wake On LAN

ICH I/O Controller HubIDE Intelligent Drive ElectronicsIPSEC Internet Protocol Security

Page 32: Technisches Handbuch / Technical Manual Mainboard D1501manuals.ts.fujitsu.com/file/3343/d1501-thb-en.pdf · Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe

Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu-ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So-lutions.

This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.

Contact and support addresses will now be offered by Fujitsu Technology So-lutions and have the format …@ts.fujitsu.com.

The Internet pages of Fujitsu Technology Solutions are available at http://ts.fujitsu.com/... and the user documentation at http://manuals.ts.fujitsu.com.

Copyright Fujitsu Technology Solutions, 2009

Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit-dem den Namen Fujitsu Technology Solutions.

Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.

Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.

Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.

Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die Benutzerdokumentation.

Copyright Fujitsu Technology Solutions, 2009


Recommended