1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch-Wächter ® Pos: 2 /#Neustruktur#/Online-Dokumentation (+KNX)/Titelblätter/Waechter/Titelblatt - 6847-6867-MasterLINE -- BJE @ 24\mod_1338458140180_15.docx @ 214600 @ @ 1 6847 220 MasterLINE 6867 280 MasterLINE === Ende der Liste für Textmarke Cover ===

1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

1473-1-8102 │ Rev. 01 │ 11.2012

Operating Instructions Busch-Wächter®

Pos: 2 /#Neustruktur#/Online-Dokumentation (+KNX)/Titelblätter/Waechter/Titelblatt - 6847-6867-MasterLINE -- BJE @ 24\mod_1338458140180_15.docx @ 214600 @ @ 1

6847 220 MasterLINE 6867 280 MasterLINE

=== Ende der Liste für Textmarke Cover ===

Page 2: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter®

Operating Instructions | 1473-1-8102 — 2 —

Pos: 4 /#Neustruktur#/Online-Dokumentation (+KNX)/Inhaltsverzeichnis (--> Für alle Dokumente <--)/Inhaltsverzeichnis @ 19\mod_1320649044386_15.docx @ 109653 @ @ 1

1 Safety ....................................................................................................................................................................... 3 2 Intended use ............................................................................................................................................................ 3 3 Environment ............................................................................................................................................................. 3 4 Setup and function ................................................................................................................................................... 4

4.1 Busch-Watchdog 220 MasterLINE .......................................................................................................... 4 4.2 Busch-Watchdog 280 MasterLINE .......................................................................................................... 4 4.2.1 General ................................................................................................................................................... 4 4.3 Features of function and equipment ........................................................................................................ 4 4.4 Detection ranges ..................................................................................................................................... 5 4.4.1 Overview of the detection range for Busch-Watchdogs 220 - 280 MasterLINE ...................................... 5 4.4.2 Limitation of the detection range ............................................................................................................. 5 4.5 Busch-Watchdog 220 / 280MasterLINE ................................................................................................... 5

5 Technical data.......................................................................................................................................................... 6 6 Installation and electrical connection ....................................................................................................................... 7

6.1 Requirements for the electrician ............................................................................................................. 7 6.2 Mounting ................................................................................................................................................. 8 6.2.1 Mounting methods .................................................................................................................................. 8 6.2.1.1 Wall mounting ......................................................................................................................................... 8 6.2.1.2 Wall mounting with gradient. ................................................................................................................... 9 6.2.1.3 Ceiling mounting ..................................................................................................................................... 9 6.2.2 Corner mounting ................................................................................................................................... 10 6.2.3 Installation sites .................................................................................................................................... 10 6.2.4 Preparing the installation ....................................................................................................................... 11 6.2.5 Mounting steps ...................................................................................................................................... 12 6.3 Electrical connection ............................................................................................................................. 13 6.3.1 Standard connection ............................................................................................................................. 13 6.3.2 Standard connection with extension unit push-button ........................................................................... 13 6.3.3 Standard connection with RC suppressor 6899 and relay .................................................................... 13

7 Commissioning ...................................................................................................................................................... 14 7.1 Setting / limiting the coverage and the detection range ......................................................................... 14 7.2 Activation test ........................................................................................................................................ 15

8 Operation ............................................................................................................................................................... 16 8.1 Control elements ................................................................................................................................... 16 8.2 Standard operation ............................................................................................................................... 16 8.3 Standard operation (time- and brightness dependent) .......................................................................... 17 8.4 Auxiliary post operation ......................................................................................................................... 17 8.4.1 Operation with extension unit push-button ............................................................................................ 17

9 Remote control ....................................................................................................................................................... 18 9.1 Control elements of the remote control ................................................................................................. 18 9.2 Technical data of the remote control ..................................................................................................... 18 9.3 Commissioning of remote control .......................................................................................................... 19 9.4 Battery change of remote control .......................................................................................................... 19

=== Ende der Liste für Textmarke TOC ===

Page 3: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Safety

Operating Instructions | 1473-1-8102 — 3 —

Pos: 6 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_1302612791790_15.docx @ 103357 @ 1 @ 1

1 Safety Pos: 7 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ @ 1

Warning Electric voltage! Risk of death and fire due to electrical voltage of 230 V. – Work on the 230V supply system may only be performed by authorised electricians! – Disconnect the mains power supply prior to installation and/or disassembly!

Pos: 8 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Bestimmungsgemäßer Gebrauch @ 18\mod_1302763321316_15.docx @ 103483 @ 1 @ 1

2 Intended use Pos: 9 /#Neustruktur#/Online-Dokumentation (+KNX)/Bestimmungsgemäßer Gebrauch (--> Für alle Dokumente <--)/Busch-Dimmer/Bestimmungsgemäßer Gebrauch @ 23\mod_1335350449857_15.docx @ 208763 @ @ 1

The device is to be used exclusively with the components that are supplied and licensed as described in chapter "Setup and function". Pos: 10.1 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/U - Z/Umwelt @ 18\mod_1302614158967_15.docx @ 103383 @ 1 @ 1

3 Environment Pos: 10.2 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Hinweise/Hinweis - Umwelt - Hinweis Elektrogeräte @ 18\mod_1302763973434_15.docx @ 103500 @ @ 1

Consider the protection of the environment! Used electric and electronic devices must not be disposed of with domestic waste. – The device contains valuable raw materials which can be recycled. Therefore, dispose of the

device at the appropriate collecting depot.

Pos: 10.3 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Hinweise/Hinweis - Umwelt - Entsorgung Elektrogeräte @ 20\mod_1325760695972_15.docx @ 136583 @ @ 1

All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies. The products meet the legal requirements, in particular the laws governing electronic and electrical devices and the REACH ordinance. (EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS) (EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006) Pos: 11 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1

Page 4: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Setup and function

Operating Instructions | 1473-1-8102 — 4 —

Pos: 12 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Aufbau und Funktion @ 11\mod_1279185435352_15.docx @ 83027 @ 111 @ 1

4 Setup and function Pos: 13 /#Neustruktur#/Online-Dokumentation (+KNX)/Aufbau und Funktion/Waechter/Funktionen - 6847-6867 220-280 MasterLINE @ 28\mod_1347514544179_15.docx @ 233163 @ 2223 @ 1

4.1 Busch-Watchdog 220 MasterLINE

The Busch-Watchdog 220 MasterLINE is a movement detector with a detection range of 220° and is suitable for use in the home and for mounting to the wall or ceiling. The Busch-Watchdog is ideally suited for larger properties and free-standing buildings. 4.2 Busch-Watchdog 280 MasterLINE

The Busch-Watchdog 280 MasterLINE is a movement detector with a detection range of 280° and is suitable for use in the home and for mounting to the wall or ceiling. The Busch-Watchdog is ideal for the surveillance of two sides of a building. 4.2.1 General

The Busch-Watchdogs are passive infrared movement detectors which switch loads via the KNX bus when sources of heat move within its detection range. Busch Watchdog is not an intrusion or attack alarm. Pos: 14 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/2. Ebene/A - F/Funktions- und Ausstattungsmerkmale @ 23\mod_1336557630140_15.docx @ 209136 @ 2 @ 1

4.3 Features of function and equipment Pos: 15 /#Neustruktur#/Online-Dokumentation (+KNX)/Aufbau und Funktion/Waechter/Ausstattungsmerkmale - 6847-6867 220-280 MasterLINE @ 29\mod_1348044135054_15.docx @ 234009 @ 1 @ 1

Comparison of functions: Function Busch-Watchdog 220 Busch-Watchdog 280 Coverage of 16 m x x

Wider lens - x

Operating mode, twilight setting, switch-off delay and short-time pulse x x

Automatic interference suppression and presence simulation x x

Range stabilisation x x

Operation via remote control x x

Extension unit operation x x

Use of corner adapter - x

Note about surveillance of two sides of a buildingDetection of two sides of a building only possible with the corner adapter! More details are available in chapter 6.2.2 "Mounting methods" for corner adapter on page 10.

Pos: 16 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ 11 @ 1

Page 5: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Setup and function

Operating Instructions | 1473-1-8102 — 5 —

Pos: 17 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/2. Ebene/A - F/Erfassungsbereiche @ 19\mod_1320393658466_15.docx @ 109558 @ 22333 @ 1

4.4 Detection ranges Pos: 18 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/3. Ebene/U - Z/Übersicht der Erfassungsbereiche Busch-Wächter 220-280 @ 28\mod_1347517634430_15.docx @ 233219 @ 333 @ 1

4.4.1 Overview of the detection range for Busch-Watchdogs 220 - 280 MasterLINE Pos: 19 /#Neustruktur#/Online-Dokumentation (+KNX)/Erfassungsbereiche/Waechter/Erfassungsbereiche - 6847-6867 220-280 MasterLINE @ 28\mod_1347514597367_15.docx @ 233177 @ 1333 @ 1

Fig. 1: Detection ranges

Detection range • The detection range is 220° and 280° and the coverage is 16 m. • The movement detector also has rearfield detection of one meter. Wall mounting • The movement detector offers optimum surveillance if mounted to the wall at a maximum height of 2.5 m. Pos: 20 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/3. Ebene/A - F/Erfassungsbereiche Reduzierung @ 29\mod_1347612043430_15.docx @ 233618 @ 22222 @ 1

4.4.2 Limitation of the detection range Pos: 21 /DinA4 - Anleitungen Online/Inhalt/Waechter/Erfassungsbereiche Einengung - 220° - 280° @ 28\mod_1347516663330_15.docx @ 233205 @ 22 @ 1

4.5 Busch-Watchdog 220 / 280MasterLINE

Use of adhesive film: The horizontal detection ranges of the Busch-Watchdogs are 220° and 280°. The detection range can be limited in case of special local circumstances. To do this, proceed as follows. 1. Cut the included adhesive film to the desired length. 2. Glue the section of covering foil from the front onto the area of the lens of your Busch-Watchdog where the

detection is to be blocked out.

Note For an illustration see chapter 7.1 on page 14.

Pos: 22 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ 1 @ 1

2,5

m

max. 16 m

16 m1 m

max. 16 m

220° 280°

Page 6: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Technical data

Operating Instructions | 1473-1-8102 — 6 —

Pos: 23 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Technische Daten @ 11\mod_1279185386320_15.docx @ 83019 @ 112 @ 1

5 Technical data Pos: 24 /#Neustruktur#/Online-Dokumentation (+KNX)/Technische Daten/Waechter/Technische Daten - 6847-6867 MasterLINE @ 24\mod_1338458229291_15.docx @ 214614 @ 2 @ 1

Designation Value Nominal voltage 230 V AC ± 10% 50 / 60 Hz

Switching capacity 3680 W/VA

Maximum switching current: 16 AX

Maximum power loss < 1 W

Horizontal detection • Busch-Watchdog 220 220°

• Busch-Watchdog 280 280°

Twilight sensor 0.5 … 300/∞ lux

Switch-off delay 10 seconds … 30 minutes

Short-time pulse • Pulse duration 1 second

• Pause time 9 seconds • Pause time with continuous light /

presence simulation

55 seconds

Coverage (if mounted 2.5 m high)

Maximum of 16 m

Operating temperature -25°C … 55°C

Protection type IP 55

Pos: 25 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Hinweise - Allgemein/Hinweis - Anschluss von EVG's - Herstellerangaben @ 24\mod_1338458660462_15.docx @ 214629 @ @ 1

Information for the connection of ballasts Please observe the following points regarding high inrush currents for ballasts: - The ballast manufacturer’s specification determines the possible number of ballasts.

Pos: 26 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ 221 @ 1

Page 7: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Installation and electricalconnection

Operating Instructions | 1473-1-8102 — 7 —

Pos: 27 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/M - O/Montage und elektrischer Anschluss @ 23\mod_1336477157864_15.docx @ 209033 @ 3333 @ 1

6 Installation and electrical connection Pos: 28 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Niederspannungs- und 230 V-Leitungen @ 23\mod_1336558868201_15.docx @ 209164 @ 2 @ 1

Warning Electric voltage! Risk of death due to electrical voltage of 230 V during short-circuit in the low-voltage line. - Low-voltage and 230 V lines must not be installed together in a flush-mounted socket!

Pos: 29 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Fachkenntnisse @ 23\mod_1336559183027_15.docx @ 209179 @ 112 @ 1

6.1 Requirements for the electrician

Warning Electric voltage! Install the device only if you have the necessary electrical engineering knowledge and experience. • Incorrect installation endangers your life and that of the user of the electrical system. • Incorrect installation can cause serious damage to property, e.g. due to fire. The minimum necessary expert knowledge and requirements for the installation are as follows: • Apply the "five safety rules" (DIN VDE 0105, EN 50110): 1. Disconnect from power; 2. Secure against being re-connected; 3. Ensure there is no voltage; 4. Connect to earth and short-circuit; 5. Cover or barricade adjacent live parts. • Use suitable personal protective clothing. • Use only suitable tools and measuring devices. • Check the supply network type (TN system, IT system, TT system) to secure the following

power supply conditions (classic connection to ground, protective earthing, necessary additional measures, etc.).

Pos: 30 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ 3222 @ 1

Page 8: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Installation and electricalconnection

Operating Instructions | 1473-1-8102 — 8 —

Pos: 31 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.docx @ 103424 @ 3234443333 @ 1

6.2 Mounting Pos: 32 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ 31 @ 1

Warning Electric voltage! Risk of death and fire due to electrical voltage of 230 V. – Work on the 230V supply system may only be performed by authorised electricians! – Disconnect the mains power supply prior to installation and/or disassembly!

Pos: 33 /#Neustruktur#/Online-Dokumentation (+KNX)/Montage/Waechter/Montage - 6847-6867_220-280 MasterLINE @ 24\mod_1338446781648_15.docx @ 214481 @ 222222224223333 @ 1

Caution

Risk of damaging the device! The lens of the device is sensitive and can easily sustain damage. - Do not press on the lens when

setting the device!

6.2.1 Mounting methods

There are four methods of mounting the Busch-Watchdog MasterLINE range. The mounting hole is compatible with all previously available Busch-Watchdog models. The possible mounting methods are described in the following.

Note The adapters for the following mounting methods must be ordered separately: - Wall mounting with gradient - Ceiling mounting (for the desired position) - Corner adapter

6.2.1.1 Wall mounting

Fig. 2: Wall mounting Classic wall mounting

Page 9: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Installation and electricalconnection

Operating Instructions | 1473-1-8102 — 9 —

6.2.1.2 Wall mounting with gradient.

Fig. 3: Wall mounting with gradient. Wall mounting with gradient is recommended on a building situated on a hill or with a gradient. This allows the detection ranged to be used effectively. 6.2.1.3 Ceiling mounting

Fig. 4: Ceiling mounting

There are two options for ceiling mounting: 1. From the bottom for a wider detection range. 2. With a corner adapter, which allows the device to be ideally positioned.

Page 10: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Installation and electricalconnection

Operating Instructions | 1473-1-8102 — 10 —

6.2.2 Corner mounting

Fig. 5: Corner mounting

The combination with a corner adapter is recommended for an optimal 280° detection range.

Note Detailed user information is available via the link http://www.busch-jaeger-katalog.de/index.php in the Busch-Watchdog category under accessories.

6.2.3 Installation sites

Fig. 6: Installation sites

• Ceiling mounting in narrow rooms is not recommended. • The mounting height of the device should be between 1.7 m and 2.5. m. • The distance between light and movement detector should be at least 1.5 m. • For optimum detection of persons the approach into the detection range should always be offset and never

frontal.

>1,7 m

Page 11: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Installation and electricalconnection

Operating Instructions | 1473-1-8102 — 11 —

6.2.4 Preparing the installation

To prepare the installation of the device, perform the following steps:

Fig. 7: Preparing the installation

1. Remove the locking screw (1) (if installed). 2. Press in the clamps (2 ... 5) on the sides of the housing with a suitable tool. 3. Carefully remove the front of the device.

Fig. 8: Opening the water drain Depending on where the device is installed, the water drain may have to be opened. • To do this, pierce the plastic membrane on the bottom of the device. The installation is prepared.

1

2 3

4

5

Page 12: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Installation and electricalconnection

Operating Instructions | 1473-1-8102 — 12 —

6.2.5 Mounting steps

Fig. 9:

1. Mount the device to the wall. - Do not use countersunk head screws for mounting

to the wall. - Use screws with a head diameter of 6.5 mm - 8.5

mm.

2. Connect the power to the device, see section 6.3. - Observe the maximum admissible cable cross

sections.

- The bolting dimensions of the base may be

compatible with existing bores on older versions of the Busch-Watchdog.

- Latch the upper part of the device onto the base.

3. To protect the device against unauthorized opening, the

enclosed screw can be used on the bottom of the device.

- To protect the device against unauthorized opening, screw the enclosed screw into the bottom of the device.

Pos: 34 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ 3233 @ 1

∅6,5 mm - 8,5 mm

∅3,5 mm - 3,9 mm

mm5,41.xam

²mm5,2 -5,1

Page 13: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Installation and electricalconnection

Operating Instructions | 1473-1-8102 — 13 —

Pos: 35 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/2. Ebene/A - F/Elektrischer Anschluss @ 21\mod_1328177051724_15.docx @ 138042 @ 223233 @ 1

6.3 Electrical connection Pos: 36 /#Neustruktur#/Online-Dokumentation (+KNX)/Anschluss/Waechter/Anschluss - 6847-6867 220-280 MasterLINE @ 24\mod_1338459376540_15.docx @ 214643 @ 11133 @ 1

6.3.1 Standard connection

Fig. 10: Universal relay insert

6.3.2 Standard connection with extension unit push-button

Fig. 11: Universal relay insert with extension unit push-button

Note For more information see chapter "Extension unit operation" 8.4 on page 17.

6.3.3 Standard connection with RC suppressor 6899 and relay

Fig. 12: Universal relay insert with RC suppressor 6899 and relay

Pos: 37 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ 212 @ 1

N L

16A

N

L

N

L

N L

16A

N L

N

L

16A

Page 14: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Commissioning

Operating Instructions | 1473-1-8102 — 14 —

Pos: 38 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/G - L/Inbetriebnahme @ 11\mod_1279185496977_15.docx @ 83035 @ 1222 @ 1

7 Commissioning Pos: 39 /#Neustruktur#/Online-Dokumentation (+KNX)/Inbetriebnahme/Waechter/Inbetriebnahme - 6847-6867 -- 220-280 MasterLINE @ 24\mod_1338448339667_15.docx @ 214542 @ 3221233 @ 1

7.1 Setting / limiting the coverage and the detection range

Caution

Risk of damaging the device! The lens of the device is sensitive and can easily sustain damage. - Do not press on the lens when

setting the device.

Use the following steps to set the coverage and the detection range:

Fig. 13: Adjusting the lateral detection range 1. Adjust the lateral detection range by turning the head of the device.

Fig. 14: Adjusting the coverage 2. Adjust the coverage by lifting or lowering the head of the device. – The minimum coverage is 6 m.

30°

Page 15: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Commissioning

Operating Instructions | 1473-1-8102 — 15 —

Fig. 15: Adjusting the detection range by masking

3. The range can be specifically limited by gluing on the enclosed foil. – Cut the enclosed foil to the size required. The coverage and the detection range are set. 7.2 Activation test

The activation test can also be triggered via the service remote control (see separate operating manual).

Fig. 16: Control element

To carry out the activation test, perform the following steps: 1. Set selector switch to T/S. - The device is now in test mode for 10 minutes (daytime operation, switch-off delay 2 sec.). In addition,

each detection is indicated by the status LED flashing quickly. - The device then switches back to standard operating mode. 2. To carry out an additional activation test, set the selector switch back to position T/S or interrupt the operating

voltage supply for more than 15 seconds. - The device is now in test mode for another 10 minutes. Test mode is exited automatically after 10 minutes

or by adjusting the brightness. The activation test has been carried out. Pos: 40 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ 1122 @ 1

T/S

0315

51min

10 sek

Page 16: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Operation

Operating Instructions | 1473-1-8102 — 16 —

Pos: 41 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Bedienung @ 11\mod_1279185541649_15.docx @ 83043 @ 2221 @ 1

8 Operation Pos: 42 /#Neustruktur#/Online-Dokumentation (+KNX)/Bedienung/Waechter/Bedienung - 6847-6867 @ 24\mod_1338459472320_15.docx @ 214658 @ 22333222 @ 1

8.1 Control elements

Fig. 17: Control elements

No. Function 1 LED

• On – continuous light set (only possible with remote control) - Flashes fast - detection in test mode

• Flashes 3 times - detection in standard and normal operation • Flickers: incoming IR signals (remote control)

2 Lens

3 Trim potentiometer for switch-off delay, short-time pulse

4 Trim potentiometer for brightness value, test/standard operation

5 Screw for dismantling safety

8.2 Standard operation

Fig. 18: Standard operation

Lighting during advancing twilight remains switched on for 3 minutes after the last detection.

After activating the mains supply voltage the device remains in test mode for 10 minutes (see chapter "Activation test").

11

2

3

4

5

T/S

Page 17: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Operation

Operating Instructions | 1473-1-8102 — 17 —

8.3 Standard operation (time- and brightness dependent)

Fig. 19: Normal operation Set the values for the brightness limit value and the switch-off delay (on period of the light after the last detection). Short-time pulse for activating the staircase light timer switches or door bells. Icon Function

Switching during all brightness levels

Switching during advancing twilight

Switching during darkness

Short-time pulse

Pos: 43 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/2. Ebene/M - O/Nebenstellenbetrieb @ 18\mod_1308568178899_15.docx @ 107029 @ 223 @ 1

8.4 Auxiliary post operation Pos: 44 /#Neustruktur#/Online-Dokumentation (+KNX)/Nebenstellenbetreib/Waechter/Nebenstellenbetrieb - 68476867 -- 220-280 MasterLINE @ 28\mod_1347514657878_15.docx @ 233191 @ 1111 @ 1

8.4.1 Operation with extension unit push-button

Aside from the movement detector being triggered by the infrared radiation in the detection range, manual operation is possible via an extension unit push-button. For example, when an exit is not within the detection range of the movement detector, the extension unit push-button can be used. The lighting can there be switched on or off manually with the push-button.

Fig. 20: Operation with extension unit push-button

• When operating with an extension unit push-button, the lighting for the set operating mode is switched on. Pos: 45 /#Neustruktur#/Online-Dokumentation (+KNX)/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ 21222 @ 1

T/S

0315

51min

10 sek

Page 18: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Remote control

Operating Instructions | 1473-1-8102 — 18 —

Pos: 46 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/G - L/Handsender @ 24\mod_1338471401020_15.docx @ 214714 @ 21222 @ 1

9 Remote control Pos: 47 /#Neustruktur#/Online-Dokumentation (+KNX)/Sonstige/Handsender/Waechter/Handsender - 6847-6867 @ 24\mod_1338471592389_15.docx @ 214731 @ 22222 @ 1

9.1 Control elements of the remote control

Fig. 21: Control elements No. Function 1 Resetting the switch-on brightness to the settings of the potentiometers on the Busch-Watchdog.

- Press the button for at least 1 second.

2 The current brightness is set as switch-on brightness.

- Press the button for at least 1 second.

3 Deactivation of presence simulation.

4 Presence simulation activation. – Continuous light between twilight and 22:30 p.m. CET or 23:30 CEST. Followed by movement detection.

5 Light deactivation for 4 hours.

– No detection of movement.

6 Light activation for 4 hours.

– No detection of movement.

7 Resetting to automatic movement detection.

The sensitivity of the movement sensors can be adjusted to surroundings which are particularly restless or free of movement.

9.2 Technical data of the remote control

Designation Value Operating voltage: 3 V DC

Battery type: CR 2025

Battery life: Approximately 2 years

Coverage: Maximum of 6 m

Protection type: IP 40

Operating temperature: 0°C … 45°C

2

4

6

7

1

3

5

Page 19: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter® Remote control

Operating Instructions | 1473-1-8102 — 19 —

9.3 Commissioning of remote control

Fig. 22: Removing the protective foil from the battery

Remove the protective foil from the battery before commissioning.

Fig. 23: Programming the remote control

• Press the "AUTO" button on the remote control for at least 3 seconds within the period of 10 minutes after

activating the power on the Busch-Watchdog. - The Busch-Watchdog must be de-energized beforehand for at least 30 seconds. - The remote control will then automatically connect itself to the Busch-Watchdog, and the Busch-

Watchdog will flash if the reception is correct. - Repeat these steps to program a maximum of 9 additional remote controls. 9.4 Battery change of remote control

Fig. 24: Changing the battery

1. Pull the battery holder out of the remote control. 2. Insert a new battery of type 2025. - The plus pole of the battery (+) must be on top. 3. Push the battery holder back into the device. === Ende der Liste für Textmarke Content ===

+CR 2025

Page 20: 1473-1-8102 Rev. 01 11.2012 Operating Instructions Busch

Operating Instructions

Busch-Wächter®

1473

-1-8

102

| R

ev. 0

1 |

11.

2012

Pos: 49 /#Neustruktur#/Online-Dokumentation (+KNX)/Rückseiten (--> Für alle Dokumente <--)/Rückseite - Busch-Jaeger - Allgemein @ 28\mod_1347009779995_15.docx @ 232282 @ @ 1

A member of the ABB Group Busch-Jaeger Elektro GmbH PO box 58505 Lüdenscheid Freisenbergstraße 2 58513 Lüdenscheid Germany www.BUSCH-JAEGER.com [email protected] Central sales service: Phone: +49 (0) 2351 956-1600 Fax: +49 (0) 2351 956-1700

Notice

We reserve the right to at all times make

technical changes as well as changes to the

contents of this document without prior notice.

The detailed specifications agreed to at the time

of ordering apply to all orders. ABB accepts no

responsibility for possible errors or

incompleteness in this document.

We reserve all rights to this document and the

topics and illustrations contained therein. The

document and its contents, or extracts thereof,

must not be reproduced, transmitted or reused by

third parties without prior written consent by ABB.

Copyright© 2012 Busch-Jaeger Elektro GmbH

All rights reserved

=== Ende der Liste für Textmarke Backcover ===