22
14 TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE DETECTION September 8 - 10, 2009 Universität Duisburg-Essen Duisburg, Germany Preliminary Program Revision 22.07.09

14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

14TH INTERNATIONAL CONFERENCE

on AUTOMATIC FIRE DETECTION

September 8 - 10, 2009 Universität Duisburg-Essen

Duisburg, Germany

Preliminary Program Revision 22.07.09

Page 2: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

EINLADUNG Die 14. Internationale Konferenz über Automatische Brand-entdeckung AUBE '09 wird wieder an der Universität Duisburg-Essen in Duisburg, Deutschland stattfinden.

Auf den folgenden Seiten finden Sie das vorläufige Programm und die Hinweise für Anmeldung und Hotelreservierung sowie weitere Informationen über die Tagung. Während der Tagung wird teilweise eine Simultanübersetzung in deutsch, englisch und eventuell französisch bereitgestellt.

Die Tagung umfasst neben dem Vortragsprogramm eine Posterdarstellung und eine Ausstellung begrenzten Umfanges.

Zur "14. Internationalen Konferenz über AUTOMATISCHE BRANDENTDECKUNG", AUBE '09, lade ich Sie sehr herzlich ein.

INVITATION The 14th International Conference on Fire Detection AUBE ’09 will be hosted by the University Duisburg-Essen and held in Duisburg, Germany again.

On the following pages the preliminary conference programme as well as the procedures for registration and hotel reservation plus further useful information about the conference is given. During one part of the conference simultaneous translation into English, German and possibly French will be provided.

The conference includes a poster presentation and will be completed by a limited tabletop exhibition.

It is my very great pleasure to extend our cordial invitation to the AUBE '09, "14th International Conference on AUTOMATIC FIRE DETECTION” to you.

INVITATION La 14ième conférence internationale sur la détection automatique d’incendie AUBE '09 aura lieu de nouveau à l’université de Duisburg-Essen, Allemagne.

Vous trouverez aux pages suivantes le programme provisoire de la conférence, les indications concernant l'inscription, les réservations d' hôtels ainsi que d' autres informations liées à la conférence. Une traduction simultanée en allemand, en anglais et éventuellement en français aura lieu durant la conférence.

La conférence comporte non seulement un programme d'exposés ais aussi une présentation de posters et une exposition limitée. m

En me permettant de vous inviter à assister à la "14ième conférence internationale sur le thème de DETECTION AUTOMATIQUE D'INCENDIE", AUBE '09, recevez, Monsieur, Madame, mes sentiments les meilleurs.

Prof. Dr.-Ing. I. Willms Prof. em. Dr.-Ing. H. Luck

-1-

Page 3: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

PROGRAMM / PROGRAMME / PROGRAMME

Dienstag Tuesday Mardi 8. Sept. 2009 MD 162 08:00 h Beginn: Anmeldung / Registration / Inscription

09:30 h Eröffnung der AUBE ’09 durch den Prorektor für Forschung, wissenschaftlichen Nachwuchs & Wissenstransfer der Universität Duisburg-Essen, Professor Dr. Michael Farle

09:45 h Grußworte des Präsidenten der vfdb, Dipl.-Phys. H. J. Blätte

09:55 h Grußworte des Präsidenten der EURALARM, Dr. H. Mahler

Session 1 Standards, certification, EU regulations, EU directives and related aspects

Diskussionsleitung / Chairmen / Présidents de l’Assemblée

K.-H. STAHL W. STEINKELLNER

VdS Schadenverhütung, Köln, Germany Prüfstelle für Brandschutztechnik, Wien, Austria

P. FIELD; BRE Global, Watford, UK 10:15 h Quality marks - Now and in the future

R. CONRADS; VdS Schadenverhütung, Köln, Germany 10:35 h The European Service Directive – and its possible influence on Fire Protection and Security

H. HAHN; Bosch Sicherheitssysteme, Ottobrunn, Germany

10:55 h

European Directive on Services in the Internal Market (Service Directive, SD) - Impact on Technical Security Services -

A. STAIMER; Siemens Building Technologies, Karlsruhe, Germany A. SUTOR, F. MONTRONE; Siemens AG, München, Germany

11:15 h

Availability of fire detection systems - quality criteria, influencing factors and results

M. KLOCKE; VdS Schadenverhütung, Köln, Germany 11:35 h The EU Construction Products Directive (CPD) - Mission, experience and modifications in progress with special focus on fire detection products

P. STAHL; Wagner Schweiz, Wallisellen, Switzerland 11:55 h Status of the European standardisation on multi-criteria fire detectors

12:15 h - 14:00 h Mittagspause / Lunch break / Déjeuner

-2-

Page 4: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

PROGRAMM / PROGRAMME / PROGRAMME

Dienstag Tuesday Mardi 8. Sept. 2009 MC 122 Session 2 Smoke aerosol characterisation

English language only!

Diskussionsleitung / Chairmen / Présidents de l’Assemblée

H. FISSAN T. CLEARY

IUTA, Duisburg, Germany NIST, Gaithersburg, MD, USA

H. FISSAN, C. ASBACH, T. KUHLBUSCH; Institut für Energie- und Umwelttechnik, Duisburg, Germany

10:15 h

Concept for a fire detector based on unipolar diffusion charging

T. CLEARY, J. YANG; NIST, Gaithersburg, MD, USA D. URBAN, G. RUFF, W. SHEREDY; NASA Glenn Research Center, Cleveland, Ohio, USA G. MULHOLLAND, University of Maryland, College Park, USA Z.G. YUAN, National Center for Space Exploration Research, Cleveland, Ohio, USA

10:35 h

Prediction of light scattering and ionization chamber sensor response to smolder smoke aerosols

T. SCHULTZE, I. WILLMS; NTS, Universität Duisburg-Essen, Duisburg, Germany

10:55 h

False-alarm rejection by image-based light scattering measurements

R. KNOX; Xtralis, Bentleigh East, Autralia 11:15 h Calibrated smoke detection using imaging technology

S. NAM; FM Global, Norwood, Massachusetts, USA

11:35 h

Prediction of Smoke Detector Response Time

N. CHEN, S.L. YANG; The Chinese People’s Armed Police Force Academy, Langfang, Heibei, P.R. China W.H. DONG; Shenyang Fire Research Inst., Shenyang, P.R. China

11:55 h

The experimental study on influencing factors of the false alarm in photoelectric smoke fire detectors

12:15 h - 14:00 h Mittagspause / Lunch break / Déjeuner

-3-

Page 5: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

PROGRAMM / PROGRAMME / PROGRAMME

Dienstag Tuesday Mardi 8. Sept. 2009 MD 162 Session 3 Test methods, special applications,

multiple sensor and multiple criteria detection

Diskussionsleitung / Chairmen / Présidents de l’Assemblée

G. SICA F. DISCHI

EUSAS Honorary Member, Rome, Italy Notifier Italia, S. Donato Milanese, Italy

K.H. SCHREYER; Siemens Building Technologies, München, Germany

14:00 h

The new standard EN54-25 defines the requirements for radio interconnection for fire alarm systems

P. MASSINGBERD-MUNDY; Xtralis, Hemel Hempstead, Herts., UK

14:20 h

Application of EN 54-20 compliant aspirating smoke detectors

R. JEZEQUEL; CNPP, Vernon, France 14:40 h Requirements and test methods for the thermal cameras used for the inspection of electrical installations

J. BÄRENFÄNGER; EMC Test NRW, Dortmund, Germany H. HIRSCH; Universität Duisburg-Essen, Germany G. BELLINGEN; VdS Schadenverhütung, Köln, Germany C. SCHMITZ; Novar, Neuss, Germany

15:00 h

EMC standardization for fire alarm systems

15:20 h - 16:15 h Kaffeepause / Coffee break / Pause café

C. DÜSING; Siemens, Krefeld, Germany 16:15 h Fire detection in railway applications

A. ROGNER, V. BUTTY, P. VOCKENHUBER; Metaphysics SA, Sainte-Croix, Switzerland

16:35 h

Redundancy and network construction of line type heat detector systems

C.P. MINOR, D.A. STEINHURST; Nova Research, Alexandria, VA, USA K.J. JOHNSON, S.L. ROSE-PEHRSSON, J.C. OWRUTSKY, S.C. WALES; Naval Research Lab., Washington, DC, USA D.T. GOTTUK; Hughes Ass., Baltimore, MD, USA

16:55 h

Multi-sensory detection system for damage control and situational awareness

A. DURIC, H. EBNER, M. FORSTER, I. VINAGE; Siemens Schweiz, Zug, Switzerland

17:15 h

Development of a multi-sensor detector for fire detection and life safety applications

17:35 h Ende / End / Fin

-4-

Page 6: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

PROGRAMM / PROGRAMME / PROGRAMME

Dienstag Tuesday Mardi 8. Sept. 2009 MC 122 Session 4 Smoke aerosol characterisation, gas detection

English language only!

Diskussionsleitung / Chairmen / Présidents de l’Assemblée

M. SCHNELL T. GOULET

VdS Schadenverhütung, Köln, Germany EUSAS Vice-Chairman Siemens Schweiz, Zug, Switzerland

M. COLE; Cole Innovation & Design, Australia 14:00 h Aerosol characterisation for reliable ASD operation

T. NAGASHIMA, M. DOHI; Hochiki Corporation, Tokyo, Japan

14:20 h

A flat shape scattering smoke detector with a function to discriminate the type of a fire

Q.X. ZHANG, J.J. WANG, J. FANG, Y.M. ZHANG; University of Science and Technology of China, Hefei, Anhui, P.R. China L.F. QIAO; Tsinghua University, Beijing, China

14:40 h

Characteristics of light scattering by smoke particles produced in test fires based on fractal aggregate shape model

S. KRÜGER; BAM, Berlin, Germany 15:00 h Smoke gas analysis by Fourier transform infrared spectroscopy

15:20 h - 16:15 h Kaffeepause / Coffee break / Pause café

J. KELLETER; GTE Industrieelektronik, Viersen, Germany

16:15 h

Fire-gas monitoring inside large industrial buildings - “FireLaser“

T.Z. FABIAN, P.D. GANDHI, P.E. PATTY, J.T. CHAPIN; Underwriters Lab., Northbrook, IL, USA

16:35 h

Characterization of combustion products under flaming and non-flaming conditions: Smoke alarm fire test room

K. LENKEIT; Minimax, Bad Oldesloe, Germany A. SCHUMANN, C. BECKE; Schumann-Analytics, Einbeck, Germany

16:55 h

New fire detection method using the field dependence of ion mobility for early detection of thermal decomposition products

S. BEER, A. HELWIG, W. LEGNER, G. MÜLLER; EADS Innovation Works, München, Germany O. SCHULZ; EADS, Unterschleißheim, Germany A. FREILING; Airbus Deutschland, Bremen, Germany

17:15 h

Infrared-based fire gas detection systems

17:35 h Ende / End / Fin

-5-

Page 7: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

PROGRAMM / PROGRAMME / PROGRAMME

Mittwoch Wednesday Mercredi 9. Sept. 2009 MD 162 Session 5 Type testing, field testing, calibration methods

Diskussionsleitung / Chairmen / Présidents de l’Assemblée

R. LÜTTENBERG R. PHILLIPS

VdS Schadenverhütung, Köln, Germany Electronic Testing Centre, Garston, Watford, Hertfordshire, UK

M. MEER, S. BRÜGGER; Securiton AG, Zollikofen, Switzerland M. HESELS; VdS Schadenverhütung, Köln, Germany

08:30 h

Development and background of new EN 54-22 for resettable line type heat detectors

E. CHRISTENSEN; DELTA, Horsholm, Denmark 08:50 h Type testing of wireless fire detection and alarm system components according to the new European Standard EN54-25:2008

C. REXFORT; VdS Schadenverhütung, Köln, Germany 09:10 h Testing of fire detection systems installed under special conditions

09:30 h - 10:00 h Kaffeepause / Coffee break / Pause café

S.H. ELLWOOD, D. APPLEBY; AW Technology, Earl Shilton, Leicestershire, UK

10:00 h

Calibration of multiple sensor optical smoke detectors

N.D. MARSH, T.G. CLEARY; NIST, Gaithersburg, MD, USA

10:20 h

Testing the performance of hydrogen sensors

J. HEMKE; DMT Gebäude Sicherheit, Dortmund, Germany

10:40 h

Test for effectiveness of fire detecting systems using non-VdS certified gas detectors

D. MEISSNER, T. RADLOFF; ISV, Rostock, Germany R. ROTHE; GSSO, Rostock, Germany

11:00 h

Gas monitoring of crankcases of big ships engines to prevent crankcase explosions

N. CHEN, X.M. MA; The Chinese People’s Armed Police Force Academy, Langfang, Heibei, P.R. China Z.B. MEI, W.H. DONG; Shenyang Fire Research Inst., Shenyang, P.R. China

11:20 h

The experimental study on the improvement of aerosol generator

11:40 h - 13:00 h Mittagspause / Lunch break / Déjeuner

-6-

Page 8: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

PROGRAMM / PROGRAMME / PROGRAMME

Mittwoch Wednesday Mercredi 9. Sept. 2009 MC 122 Session 6 Toxic gases, gas detection

English language only!

Diskussionsleitung / Chairmen / Présidents de l’Assemblée

D. KOHL O. LINDEN

Universität Giessen, Giessen, Germany Wagner Group, Langenhagen, Germany

Z. ANKARA; Novar, Neuss, Germany 08:30 h Multi gas sensor systems for security applications and warning systems

M. ZHU, S. WANG, D.H. XIA; Huazhong University of Science and Technology, Wuhan, P.R. China

08:50 h

Developed acoustic multi-relaxation algorithm for carbon monoxide concentration detection in gas mixtures

U. HOEFER, D. GUTMACHER; Siemens Schweiz, Zug, Switzerland

09:10 h

Event classification using single metal-oxide sensor elements

09:30 h - 10:00 h Kaffeepause / Coffee break / Pause café

T. NAKAJIMA, T. ONO; Nihon University, Tokyo, Japan 10:00 h An examination of propane gas leakage detection methods using semiconductor gas sensors

M. DEBLIQUY, D. LAHEM; Faculte Polytechnique de Mons, Mons, Belgium A. DE HAAN; Sochinor, Le Roeulx, Belgium J. CUTLER; Apollo Fire Detectors, Havant, Hampshire, UK

10:20 h

Fire detection based on new metal oxide gas sensors

O. SUGAWA, K. KAMIYA; Tokyo University of Science, Toyohira, Chino, Nagano pref., Japan

10:40 h

Sensing of spontaneous combustion in plastic waste by electronic noses

M. BAUER, J. GOTTSCHALD, T. SAUERWALD, D. KOHL; Universität Giessen, Giessen, Germany

11:00 h

Suppression of false alarms caused by cigarette smoking

11:20 h - 13:00 h Mittagspause / Lunch break / Déjeuner

-7-

Page 9: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

PROGRAMM / PROGRAMME / PROGRAMME

Mittwoch Wednesday Mercredi 9. Sept. 2009 MD 162 Session 7 Testing procedures, domestic fire detection

Diskussionsleitung / Chairmen / Présidents de l’Assemblée

H. SCHÜNGEL J. KAISER

VdS Schadenverhütung, Köln, Germany EUSAS Honorary Member, Austria

13:00 h Y. JIANG; Xtralis, Bentleigh East, Australia P. MASSINGBERD-MUNDY; Xtralis, Hemel Hempstead, Herts., UK S. WILSON; Xtralis, Norwell, MA, USA PIAB, an Innovative Way to Apply Conventional Spot Type Smoke Detectors into Wider Application Areas

L. MÖLTER, S. SCHÜTZ; Palas, Karlsruhe, Germany 13:20 h Fast and reliable production control of smoke detectors

T.Z. FABIAN, G. HUNTER, P.E. PATTY, P.D. GANDHI; Underwriters Lab., Northbrook, IL, USA

13:40 h

Smoke build-up rates for flaming and non-flaming foams

W.J. FRIEDL; Ingenieurbüro für Sicherheitstechnik, München, Germany

14:00 h

Smoke detectors in Living Areas

14:20 h - 15:30 h Poster Session, MD 164

15:30 h - 16:00 h Kaffeepause / Coffee break / Pause café

H. HERBSTER; Hekatron, Germany 16:00 h Smoke alarms for residential buildings and flats

D.T. GOTTUK, C.L. MEALY, A.J. WOLFE; Hughes Associates, Baltimore, MD, USA

16:20 h

Smoke alarm response and tenability

T. CLEARY; NIST, Gaithersburg, MD, USA 16:40 h Full-scale residential smoke alarm sensitivity

G. RÖPKE; JOB detectomat, Ahrensburg, Germany 17:00 h SRD 3000 - Rauchmelder für die Wohnwirtschaft

17:20 h Ende / End / Fin

19:30 h Empfangsbuffet / Conference dinner / Dîner de conférence AUBE ’09 Best Paper Award

Während der AUBE ’09 wird der von “Notifier Italia“ gestiftete “AUBE ’09 Best Paper Award“ in Höhe von 2000 Euro verliehen. The “AUBE ’09 Best Paper Award” is presented during AUBE ’09. The award of 2000 Euro is an endowment of “Notifier Italia”.

-8-

Page 10: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

PROGRAMM / PROGRAMME / PROGRAMME

Mittwoch Wednesday Mercredi 9. Sept. 2009 MC 122 Session 8 Gas detection, modelling and simulation

aspects, detection in special applications

English language only!

Diskussionsleitung / Chairmen / Présidents de l’Assemblée

J. FANG C. REXFORT

University of Science and Technology of China, Hefei, Anhui, P.R. China VdS Schadenverhütung, Köln, Germany

S. BOOTSMA; Comon Invent, Delft, Netherlands 13:00 h Online e-nose technology for health, safety and environmental applications

P. REIMANN, T. CONRAD, A. SCHÜTZE; Universität des Saarlandes, Saarbrücken, Germany

13:20 h

Under-ground fire detection based on a semiconductor gas sensor

M. MÜNCH; Freie Universität Berlin, Berlin, Germany 13:40 h Verification and validation of CFD-models applied to fire detection

C.L. MEALY, D.T. GOTTUK; Hughes Associates Inc., Baltimore, MD, USA

14:00 h

Validation of Smoke Detection Response Methodologies

14:20 h - 15:30 h Poster Session, MD 164

15:30 h - 16:00 h Kaffeepause / Coffee break / Pause café

R. CHAGGER, BRE Global Ltd, Watford, UK 16:00 h Smoke detection in high ceiling spaces

N. CHEN, T.W. ZHANG; The Chinese People’s Armed Police Force Academy, Langfang, Heibei, P.R. China Z.B. MEI, A.Z. WANG; Shenyang Fire Research Inst., Shenyang, Liaoning, P.R. China

16:20 h

Experimental study about the response property of photoelectric smoke fire detectors base on the hollowing rate of grid suspended ceilings

Y. OKA; Yokohama National University, Yokohama, Japan O. SUGAWA, Tokyo University of Science, SUWA, Toyohira, Japan

16:40 h

Characterization of flow behavior along an inclined unconfined ceiling

W. WERKMEISTER, T. HANSES, J. TÜRMER, G. GRÜNER, R. BERGMANN, C. HAUG, A. HENSEL; Bosch Sicherheitssysteme, Ottobrunn, Germany

17:00 h

Simulation of light scattering for different aerosols in a fire detector and comparison with experimental data

17:20 h Ende / End / Fin 19:30 h Empfangsbuffet / Conference dinner / Dîner de conférence

-9-

Page 11: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

PROGRAMM / PROGRAMME / PROGRAMME

Donnerstag Thursday Jeudi 10. Sept. 2009 MD 162 Session 9 Wireless detection, fire spread,

detection algorithms in fire and security

Diskussionsleitung / Chairmen / Présidents de l’Assemblée

M. BEMBA H. BERGER

Novar, Neuss, Germany VdS Schadenverhütung, Köln, Germany

W. VOLLENWEIDER; Siemens Schweiz, Zug, Switzerland

08:50 h

Fading in indoor radio links

H. AEBERSOLD, P. BLUM, C. HONEGGER; Siemens Schweiz, Zug, Switzerland

09:10 h

Energy as Central Design Paradigm for Wireless Fire Detection

A. RIEMER, T. FINKE, T. KÖNIG; Novar, Neuss / Albstadt, Germany

09:30 h

Security applications using wireless networking - realizing a radio controlled field bus

P. MASSINGBERD-MUNDY; Xtralis, Hemel Hempstead, Herts., UK

09:50 h

FireGrid - An integrated emergency response system

10:10 h - 10:25 h Kaffeepause / Coffee break / Pause café

D. SASCHENBRECKER, R. SCHÄCKEL; GreCon Greten, Alfeld-Hannover, Germany

10:25 h

Innovative algorithms for the effective mitigation of the risk of fires and explosions in process plants

W. VOLLENWEIDER; Siemens Schweiz, Zug, Switzerland

10:45 h

Interferences from Fluorescent Tubes to Open Smoke Detectors

Y. WANG, C.Y. YU, R. TU, Y.M. ZHANG; University of Science and Technology, Hefei, Anhui, P.R. China

11:05 h

Fire detection system in Tibet based on gray-fuzzy neural network algorithm

E. MOMMA, T. ONO, H. ISHII, S.I. OZAWA; Nihon University, Tokyo, Japan J.I. HOZUMI; Koito Industries, Japan

11:25 h

Tunnel car fire detection using Haar-like features

U. SKUBSCH; USK-Consults, Scharbeutz, Germany

11:45 h

Video content analysis for unmanned platforms

12:05 h - 13:30 h Mittagspause / Lunch break / Déjeuner

-10-

Page 12: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

PROGRAMM / PROGRAMME / PROGRAMME

Donnerstag Thursday Jeudi 10. Sept. 2009 MC 122 Session 10 Wildfire fighting, gas detection, fire spread

English language only!

Diskussionsleitung / Chairmen / Présidents de l’Assemblée

E. GABREAU SHU WANG

Siemens, Buc Cedex, France Huazhong-University of Science and Technology, Wuhan, P.R. China

N. CORSI; D’Appolonia S.p.A.-Ufficio di Roma, Italy 08:30 h An innovative approach to forest-fire detection and monitoring: The EU-Fire project

W. KRUELL, R. TOBERA, I. WILLMS; NTS, Universität Duisburg-Essen, Duisburg, Germany B. WIGGERICH; AirRobot, Arnsberg, Germany

08:50 h

Early forest fire detection and suppression - an integrated approach -

M. HENRICHS; Airmatic, Hemer, Germany 09:10 h Armored and tracked vehicle for rescue / extinguish / defend missions

N. VON WAHL, S. HEINEN; FGAN-FHR, Wachtberg, Germany

09:30 h

Advantages of millimeterwaves in fire detection and monitoring

R. TOBERA, W. KRÜLL, I. WILLMS; NTS, Universität Duisburg-Essen, Duisburg, Germany

09:50 h

Optical smoke and gas sensors as an additional method for early wildfire verification

10:10 h - 10:25 h Kaffeepause / Coffee break / Pause café

H. SCHMITZ; Universität Bonn, Bonn, Germany H. BOUSACK; Forschungszentrum Jülich, Germany M. LACHER, S. SCHMITZ; Forschungszentrum caesar, Bonn, Germany

10:25 h

The infrared sensilla in the beetle Melanophila acuminata as model for new fire sensors

S. PACZKOWSKI, B. WEISSBECKER, S. SCHÜTZ; Universität Göttingen, Göttingen, Germany A. EBERHEIM, D. KOHL; Universität Giessen, Giessen, Germany P. SCHIEBERLE; Universität München, Germany

10:45 h

Biomimetic wood smoke assessment on the basis of insect olfactory systems

R. KASCHOW; CAE Elektronik, Stolberg, Germany 11:05 h Simulation to support wildfire fighting management

J. DREIBACH, Fire Watch, Aarau, Switzerland 11:25 h Automated Wildland Smoke Detection Systems: Technology and procedure for remote sensing, early warning and Data achievement for a computer aided, efficient Fire Fighting Management

11:45 h - 13:30 h Mittagspause / Lunch break / Déjeuner

-11-

Page 13: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

PROGRAMM / PROGRAMME / PROGRAMME

Donnerstag Thursday Jeudi 10. Sept. 2009 MD 162 Session 11 Fire detection in aircraft, special applications

Diskussionsleitung / Chairmen / Présidents de l’Assemblée

A. FREILING D. KOZEKI

Airbus Deutschland, Bremen, Germany National Research Institute for Fire & Disaster, Tokyo, Japan

K. BEHLE; Airbus Deutschland, Bremen, Germany 13:30 h Standardization of false alarm rejection capability assessment

A. FREILING, K. WILLENBROCK; Airbus Deutschland, Bremen, Germany

13:50 h

Studies on the performance of smoke detectors and their housing in an aircraft cargo compartment environment

M. HEMINGWAY, P. WALSH; Health & Safety Laboratory, Buxton, UK M. WILLIAMS; Health & Safety Executive, Bootle, UK S. HUNNEYBALL; TES Bretby, Burton upon Trent, UK S. JOBLING; UK Coal, Doncaster, UK

14:10 h

An improved fire detector for use in underground coalmines

14:30 h - 14:45 h Kaffeepause / Coffee break / Pause café

E.C.L. PANG, W. K. CHOW; The Hong Kong Polytechnic University, Hong Kong, China

14:45 h

Review on design considerations of fire detection systems for supertall buildings

J. FANG, J.J. WANG, R. TU, Y.M. ZHANG; University of Science and Technology of China, Hefei, Anhui, P.R. China X.M. SHU; Tsinghua University, Beijing, China

15:05 h

An experimental evaluation about multiple fire detectors in a high large volume space

P. GUNDERMANN; Gundermann, Apolda, Germany 15:25 h Fire detection through pneumatic activator tubings

C. KAINZ; Wagner Bayern, München, Germany 15:45 h Fire prevention in rolling stock

R. LAUFERSWEILER; Hekatron, Sulzburg, Germany S. BRÜGGER; Securiton, Zollikofen, Switzerland

16:05 h

Details in developing a new high sensitivity smoke sensor for aspirating smoke detectors

F. DANIAULT, A. SIEMENS, H. LEWONIG; Wagner Group, Langenhagen, Germany A. BARKER; Wagner UK Ltd, Cambridge, UK

16:25 h

Aspirating smoke detection in prisons with identification of individual cells

16:45 h I. WILLMS; Schlusswort / Conclusion / Conclusion

-12-

Page 14: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

PROGRAMM / PROGRAMME / PROGRAMME

Donnerstag Thursday Jeudi 10. Sept. 2009 MC 122 Session 12 Detection by radiated emission, video detection

English language only!

Diskussionsleitung / Chairmen / Présidents de l’Assemblée

H.-J. MAHLER G. VAN LANGEVELD

Siemens Schweiz, Zug, Switzerland EURALARM, Brussels, Belgium

S. VERSTOCKT, B. MERCI, P. LAMBERT, R. VAN DE WALLE; Ghent University, Ledeberg-Ghent, Belgium

13:30 h

State of the art in vision-based fire and smoke detection

F. ALIMENTI, G. TASSELLI, S. BONAFONI, L. ROSELLI, P. BASILI; University of Perugia, Italy

13:50 h

Remote sensing of masked fire spots by low-cost microwave radiometers

R. SALMAN, T. SCHULTZE, M. MLADENOV, I. WILLMS; NTS, Universität Duisburg-Essen, Germany

14:10 h

Rough UWB object imaging for improved microwave fire detection

14:30 h - 14:45 h Kaffeepause / Coffee break / Pause café

A. BIRBAUMER, A. MACÉ, F. MOSCHENI, F.BETSCH; Fastcom Technology, Lausanne, Switzerland

14:45 h

Video-based fire and smoke detection in road tunnels

G.F. DING, J. OUYANG, C.S. LIM; InnoSys Industries, Pei Tou, Taipei, Taiwan Z.G. LIU; General Fire Technologies, Ottawa, Canada

15:05 h

Study of a video Image fire detection (VID) system for road tunnel protection

C.Y. YU, Y.M. ZHANG; University of Science and Technology of China, Hefei, Anhui, P.R. China

15:25 h

Video smoke detection based on optical flow features and back-propagation neural network

S. DUNKELMANN; m.u.t., Wedel, Germany 15:45 h Camera based fire detection: Synthetic video sequences for testing of detection algorithms

W. HAGEDORN; m.u.t., Wedel, Germany 16:05 h Very early fire detection and support of fire fighting by infrared video systems

H. OBERWALDER 16:25 h IR camera technology for fire fighting

16:45 h H. LUCK; Schlusswort / Conclusion / Conclusion

-13-

Page 15: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

POSTER SESSION

Mittwoch Wednesday Mercredi 9. Sept. 2009 MD 164 14:20 h - 15:30 h Diskussionsleitung / Chairmen / Présidents de l’Assemblée

P. STAHL H. LUCK

Wagner Schweiz, Wallisellen, Switzerland Universität Duisburg-Essen, Duisburg, Germany

H. BERGER; VdS Schadenverhütung, Köln, Germany Funktionserhalt für die Alarmierung von Personen im Brandfall

N. CHEN, T.W. ZHANG, S.L. YANG; The Chinese People’s Armed Police Force Academy, Langfang, Heibei, P.R. China Study on the smoke-penetration performance of grid suspended ceilings with low hollowing rate based on FDS

N. CHEN, X.M. MA; The Chinese People’s Armed Police Force Academy, Langfang, Heibei, P.R. China Z.B. MEI, W.H. DONG; Shenyang Fire Research Institute, Shenyang, Liaoning, P.R. China The experimental study on the test tunnel improvement of smoke fire detectors

S. BERNERT-FENG, I. WILLMS; NTS, Universität Duisburg-Essen, Duisburg, Germany Synthesizing and Mixture of Fire as Video Texture

T. SCHULTZE, R. SALMAN, I. WILLMS; NTS, Universität Duisburg-Essen, Duisburg, Germany Microwave ellipsometry and its application in emergency scenarios

R. TU, C.Y. YU, X. XIAO, J. FANG, Y.M. ZHANG; University of Science and Technology of China, Hefei, P.R. China Response of ordinary point-type fire smoke detectors in ISO fire tests under different ambient pressures

J.J. WANG, Y.M. ZHANG, J. FANG; University of Science and Technology of China, Hefei, Anhui, P.R. China Fire smoke particle size distribution evolution in standard fire test room

-14-

Page 16: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

RAHMENPROGRAMM Dienstag, den 8. September 2009

14:00 h - 16:30 h Besichtigung des Wilhelm Lehmbruck Museums Mittwoch, den 9. September 2009

09:30 h - 12:30 h Industriegeschichtliche Führung im Landschaftspark Nord (Industriedenkmal)

Für diese Besichtigung ist festes Schuhwerk erforderlich! 14:00 h - 16:00 h Stadtführung "Innenhafen" Donnerstag, den 10. September 2009

10:00 h - 12:30 h Der Zoo Duisburg

Um rechtzeitige Anmeldung wird gebeten, da die Teilnehmerzahl

egrenzt ist. Nähere Einzelheiten erfahren Sie im Tagungsbüro. b Abfahrt erfolgt jeweils vom Tagungsbüro.

SOCIAL PROGRAMME Tuesday, September 8, 2009

14:00 h - 16:30 h Visit to the “Wilhelm Lehmbruck” Museum Wednesday, September 9, 2009

09:30 h - 12:30 h Visit to the Duisburg-Nord Country Park, an industrial history tour

Walk around the closed-down blast-furnace plant. This visit requires tough shoes! 14:00 h - 16:00 h A guided tour to the "Inner Harbour" Thursday, September 10, 2009

10:00 h - 12:30 h A guided tour to the Duisburg Zoo

Due to the limited number of participants you are requested to ensure your booking early enough. For further details, please contact the conference office.

Departure for all visits is from the conference office.

-15-

Page 17: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

ALLGEMEINE HINWEISE

Tagungsort Universität Duisburg-Essen, Campus Duisburg Eingang Ecke Mülheimer Straße / Lotharstraße Gebäude MC (siehe beigefügten Lageplan) D-47057 Duisburg

Anmeldung Es wird um Anmeldung bis zum 7. August 2009 mittels beigelegter Anmeldekarte gebeten. Die Teilnehmergebühr beinhaltet die Teilnahme an allen fachlichen Veranstaltungen, die Tagungsunterlagen und den Tagungsband sowie das Empfangsbuffet.

Anmeldung bis zum 7. August 2009 630 € Persönliche EUSAS-Mitglieder 530 €

Anmeldung nach dem 7. August 2009 680 € Persönliche EUSAS-Mitglieder 580 €

Zusätzliche Personen am Empfangsbuffet 35 € Es wird gebeten, gleichzeitig mit der Anmeldung die Teilnahme-gebühr und evtl. den zusätzlichen Beitrag für das Empfangsbuffet auf das folgende Konto zu überweisen (bitte keine Schecks und keine Kreditkarten !):

Bank Sparkasse Essen Kontonummer 248 997

Kontoinhaber Universität Duisburg-Essen BLZ 360 501 05

IBAN code DE75 3605 0105 0000 248997 BIC code SPESDE3EXXX Kennwort AUBE '09

(Bitte Kennwort unbedingt angeben!)

Kommunikation Die Teilnehmer sind während der Tagung vom 8. bis zum 10. September 2009 über das Tagungsbüro zu erreichen.

Telefon: 0203 - 379 - 3000 Fax: 0203 - 379 - 3001

Außerhalb dieser Tage ist das Tagungsbüro erreichbar über

Telefon: 0203 - 379 - 3364 Fax: 0203 - 379 - 2902 e-mail: [email protected] Internet Infos: http://nts.uni-duisburg-essen.de

Simultanübersetzung Deutsch, englisch, eventuell französisch im Hörsaal MD 162

-16-

Page 18: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

ALLGEMEINE HINWEISE

Hotelreservierung Das Tagungsbüro übernimmt keine Hotelreservierungen. Z ur Zimmerreservierung wenden Sie sich bitte an die

Duisburg Marketing GmbH Tel. +49 (0) 203 - 285 44 0 Zentrale Reservierung Fax. +49 (0) 203 - 285 44 44

Königstraße 86 [email protected] D-47051 Duisburg / RFA http://www.duisburgnonstop.de Online buchbar sind die Hotels auch über

http://germany.nethotels.com/info/duisburg/events/aube/

Vergünstigte Hotelpreise können erzielt werden, wenn die Hotelreservierung bis 8 Wochen vor Tagungsbeginn über die "Duisburg Marketing GmbH" vorgenommen wird.

GENERAL INFORMATION

Venue University Duisburg-Essen, Campus Duisburg Entrance at the corner Mülheimer Strasse / Lotharstrasse Building MC (see enclosed map) D-47057 Duisburg / Germany

Registration Early registration (if possible, prior to August 7, 2009) using the enclosed registration card is requested. The registration fee covers the conference documents incl. proceedings and the attendance to the technical programme as well as the conference dinner. Registrations received prior to August 7, 2009 630 € Personal EUSAS members 530 €

Registrations received after August 7, 2009 680 € Personal EUSAS members 580 €

Additional participants in the conference dinner 35 € On returning your registration card, we kindly request you to transfer your registration fee including the additional charge for the conference dinner in case of participation to the following bank account (please no cheques and no credit cards!):

Bank Sparkasse Essen Account No. 248 997

Account holder Universität Duisburg-Essen Bank Code 360 501 05

IBAN code DE75 3605 0105 0000 248997 BIC code SPESDE3EXXX

Reference AUBE '09

(Reference declaration is absolutely necessary!)

-17-

Page 19: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

Communication Conference participants can be reached during the conference hours (8.-10. September 2009) under

phone: +49 (0) 203 - 379 - 3000 fax: +49 (0) 203 - 379 - 3001

Otherwise the conference office can be contacted by

phone: +49 (0) 203 - 379 - 3364 fax: +49 (0) 203 - 379 - 2902 e-mail: [email protected] Internet Infos: http://nts.uni-duisburg-essen.de

Simultaneous translation English, German, possibly French in lecture room MD 162

Hotel reservation Please, notice that room reservation cannot be made by the conference office. For hotel reservation please contact

Duisburg Marketing GmbH Tel. +49 (0) 203 - 285 44 0 Zentrale Reservierung Fax. +49 (0) 203 - 285 44 44

Königstrasse 86 [email protected] D-47051 Duisburg http://www.duisburgnonstop.de Germany

Online booking is also possible by using the link http://germany.nethotels.com/info/duisburg/events/aube/

Reduced rates for hotel accommodation may be achieved if registration is done at "Duisburg Marketing GmbH" at the latest 8 weeks prior to start of the conference.

RENSEIGNEMENTS GÉNÉRAUX

Lieu du congrès Université de Duisburg-Essen, Campus Duisburg Entrée: Coin Mülheimer Strase / Lotharstrase, bâtiment MC (voir le plan ci-joint) D-47057 Duisburg, Allemagne

Inscription Prière de s'inscrire au plus tard le 7 août 2009 en faisant usage de la carte d'inscription ci-jointe. Les frais d'inscription donnent droit à la participation aux exposés techniques et au dîner de réception ainsi qu'à la remise de divers documents. Inscription jusqu'au 7 août 2009 630 € Inscription membre individuel de l'EUSAS 530 €

Inscription après le 7 août 2009 680 € Inscription membre individuel de l'EUSAS 580 €

Dîner de réception d'une personne non-inscrite 35 €

-18-

Page 20: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

Parallèlement à votre inscription, veuillez, s'il vous plaît, virer vos frais de participation au congrès ainsi que d'autres frais éventuels au compte suivant (s.v.p., pas de chèques et pas de carte de crédit !):

Banque Sparkasse Essen Numéro de compte 248 997 Titulaire du compte Universität Duisburg-Essen

Code de banque 360 501 05 IBAN code DE75 3605 0105 0000 248997 BIC code SPESDE3EXXX Mot de passe AUBE '09

(mot de passe exigé)

Communication Durant la période du congrès, du 8 au 10 sept. 2009, les congressistes pourront être joints par téléphone par le biais du bureau de congrès au numéro

téléphone: +49 (0) 203 - 379 - 3000 fax: +49 (0) 203 - 379 - 3001

En dehors de ces jours, le bureau de congrès est accessible au numéro de

téléphone: +49 (0) 203 - 379 - 3364 fax: +49 (0) 203 - 379 - 2902. e-mail: [email protected] Internet Infos: http://nts.uni-duisburg-essen.de

Traduction simultanée Anglais, allemand, éventuellement français dans la salle MD 162

Réservation d'hôtel Le bureau du congrès ne s'occupe pas des réservations d'hôtel. Pour la réservation des chambres, veuillez, s.v.p., contacter l'adresse suivante

Duisburg Marketing GmbH Tel. +49 (0) 203 - 285 44 0 Zentrale Reservierung Fax. +49 (0) 203 - 285 44 44

Königstrasse 86 [email protected] D-47051 Duisburg http://www.duisburgnonstop.de Allemagne

Réservation par Internet http://germany.nethotels.com/info/duisburg/events/aube/

Pour obtenir des chambres d'hôtel à un tarif réduit, veuillez faire votre réservation par la "Duisburg Marketing GmbH" au plus tard 8 semaines avant le commencement du congrès.

-19-

Page 21: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

-20-

Conference Co - Chairs

Prof. Dr.-Ing. I. Willms Universität Duisburg - Essen Bismarckstrasse 81 D-47048 Duisburg / Germany e-mail: [email protected] Fon: ++49 (0) 203 - 379 - 3276 or ++49 (0) 203 - 379 - 3364 Thomas G. Cleary Building and Fire Research Lab, MS-8664 National Institute of Standards & Technology Gaithersburg, MD 20899-8664, U.S.A. e-mail: [email protected] Fon: +01 301 975 6858

Conference Honorary Chair

Prof. em. Dr.-Ing. Heinz Luck Universität Duisburg - Essen Bismarckstrasse 81 D-47048 Duisburg / Germany e-mail: [email protected] Fon: ++49 (0) 203 - 379 - 2842 or ++49 (0) 203 - 379 - 3364

Programme & Steering Committee

Thomas Cleary NIST, MD, U.S.A. Franco Dischi Notifier Italia, Italy André Freiling Airbus Deutschland, Germany Emmanuel Gabreau Siemens, France Thomas Goulet Siemens, Switzerland Reinhard Grabski Institut der Feuerwehr Sachsen-Anhalt, Germany Claus-Dieter Kohl Justus-Liebig-Universität Giessen, Germany Daisuke Kozeki National Inst. Fire & Desaster, Japan Heinz Luck Universität Duisburg-Essen, Germany Hansjürg Mahler President EURALARM, Switzerland Takashi Ono Nihon University, Japan Richard Phillips BRE, United Kingdom Wolfgang Steinkellner Prüfstelle für Brandschutztechnik, Austria Karl-Heinz Stahl VdS Köln, Germany Shu Wang Huazhong-University of Science and Technology, P.R. China Ingolf Willms Universität Duisburg-Essen, Germany

Page 22: 14TH INTERNATIONAL CONFERENCE on AUTOMATIC FIRE …nts.uni-due.de/aube/aube09/Aube09_preliminary... · 14TH INTERNATIONAL . CONFERENCE . on . AUTOMATIC FIRE DETECTION. September 8

Lageplan Tagungsort (Gebäude MD / MC) Map of conference area (Building MD / MC)

Der Tagungsort (Gebäude MD und MC, Mülheimer Straße) ist ab Duisburg Hauptbahnhof mit der Straßenbahn-Linie 901 bis Haltestelle "Zoo/Uni" oder mit den Bus-Linien 924, 926 und 933 bis Haltestelle "Uni-Nord" / "Uni-Nord, Lotharstraße" zu erreichen. From main station Duisburg you can reach the conference buildings MD and MC (Mülheimer Strasse) either by tram No. 901 via tram stop "Zoo/Uni" or by bus No. 924, 926 and 933 via bus stop "Uni-Nord" / "Uni-Nord, Lotharstrasse".