5
Cod. Fiscale e Partita I.V.A. IT01156060038 Capitale Soc.: Euro 100.000,00 Int. Vers. CCIAA V.C.O. N. 152820 NUGO ROMANO S.p.A. Via Area Artigianale Sassonia, 6 28885 Piedimulera (VB) Italy Tel. +390324848700 Fax. +39032483341 www.nugoromano.it [email protected] PEC [email protected] Nugo Romano S.p.A. provides its expertise in the field of NDT and dimensional checks with highly specialized and qualified personnel, operating both in the company and at customers and suppliers premises. In particular, the company is able to perform the following checks: LIQUID PENETRANT TESTS (PT) The liquid penetrant test is aimed at verifying discontinuities such as cracks, overlaps, folds, and missed fusion that appear on the surface to be tested. The check is carried out mainly on metallic materials, but can also be performed on other materials, provided that they are inert to the products used for the investigation and are not excessively porous. The penetration of the liquid inside a discontinuity occurs by capillarity and not by gravity. This prerogative, which is the basis of all the control methodology, makes easy to inspect surfaces that are difficult to access regardless of its position. The company employs qualified and certified staff for Non-Destructive Test according to the UNI EN ISO 9712: 2012 standard: 2 PT operators of Level III and 2 PT operators of Level II

LIQUID PENETRANT TESTS (PT ) · The penetration of the liquid inside a discontinuity occurs by capillarity and not by gravity. This prerogative, which is the basis of all the control

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LIQUID PENETRANT TESTS (PT ) · The penetration of the liquid inside a discontinuity occurs by capillarity and not by gravity. This prerogative, which is the basis of all the control

Cod. Fiscale e Partita I.V.A. IT01156060038 Capitale Soc.: Euro 100.000,00 Int. Vers. CCIAA V.C.O. N. 152820

NUGO ROMANO S.p.A. Via Area Artigianale Sassonia, 6 28885 Piedimulera (VB) Italy T e l . + 3 9 0 3 2 4 8 4 8 7 0 0 F a x . + 3 9 0 3 2 4 8 3 3 4 1 w w w . n u g o r o m a n o . i t i n f o @ n u g o r o m a n o . i t

PEC nugoromano@regis terpec.i t

Nugo Romano S.p.A. provides its expertise in the field of NDT and dimensional checks with

highly specialized and qualified personnel, operating both in the company and at customers and

suppliers premises. In particular, the company is able to perform the following checks:

LIQUID PENETRANT TESTS (PT)

The liquid penetrant test is aimed at verifying discontinuities such as cracks, overlaps, folds, and

missed fusion that appear on the surface to be tested. The check is carried out mainly on metallic

materials, but can also be performed on other materials, provided that they are inert to the products

used for the investigation and are not excessively porous.

The penetration of the liquid inside a discontinuity occurs by capillarity and not by gravity. This prerogative, which is the basis of all the control methodology, makes easy to inspect surfaces that are

difficult to access regardless of its position.

The company employs qualified and certified staff for Non-Destructive Test according to the UNI EN

ISO 9712: 2012 standard: 2 PT operators of Level III and 2 PT operators of Level II

Page 2: LIQUID PENETRANT TESTS (PT ) · The penetration of the liquid inside a discontinuity occurs by capillarity and not by gravity. This prerogative, which is the basis of all the control

MAGNETOSCOPIC TEST (MT)

Magnetoscopic test is a non-destructive testing method, which uses the iron-magnetic properties

of some materials to become magnetized and thus transmit the magnetic flux. Magnetoscopy is able to detect the possible presence of surface and sub-surface discontinuities on

the pieces examined, by thickening of the magnetic powder in correspondence with the dispersed

flow. The immediacy of the magnetoscopic control result, linked to a simple interpretation of the

indications, make it a non-destructive testing method complementary to the penetrating liquids with

the advantage of an increased depth of examination. The control method with magnetic particles is

widely used not only in the production phase but also in the periodic maintenance and verification

phase.

In the company there is staff qualified and certified for Non-Destructive Tests according to the standard

UNI EN ISO 9712: 2012: 2 operators for MT Level III and 2 operators for MT Level II

Page 3: LIQUID PENETRANT TESTS (PT ) · The penetration of the liquid inside a discontinuity occurs by capillarity and not by gravity. This prerogative, which is the basis of all the control

ULTRASOUND TEST (UT)

The ultrasounds are constituted by elastic waves, which propagate in the materials even along

considerable paths. The method uses high frequency sound waves (ultrasound/UT) which pass through the material to be examined. These non-destructive checks exploit the capacity of particular

mechanical vibrations with frequencies higher than that audible from the human ear, the variations in

acoustic impedance caused by discontinuities within the product, generate response signals that, when

properly interpreted, can lead to the identification of the defect present inside the product.

This ultrasonic method of non-destructive tests is generally applied to forged, welded products and

thickness tests.

In the company there is staff qualified and certified for Non-Destructive Tests according to standard UNI EN ISO 9712: 2012: 2 operators for UT Level III and 2 operators for UT Level II.

Page 4: LIQUID PENETRANT TESTS (PT ) · The penetration of the liquid inside a discontinuity occurs by capillarity and not by gravity. This prerogative, which is the basis of all the control

VISUAL TEST (VT) Visual check is the control method used by everybody, in all inspection methods. The visual inspection

can be done simply by "naked eye" therefore without the aid of optical instruments or with the assistance

of lenses, mirrors, endoscopes, borescopes, fiberscopes and video endoscopes. Particularly important

is also the level of illumination of the surface that must be compliant with the specifications and

implemented in such a way as not to preclude visual examination.

The VT inspector covers various tasks: classification and sizing of defects for check of compliance with product standards on welds, forgings, castings and plates, check of compliance with welding

procedures, dimensional check of welds, dimensional check of products in general, painting check,

macrographs, etc.

In metallurgy, for the identification of discontinuities, visual check is used in all production contexts.

The defectology treated by the method regards all the production and post-production phases,

therefore it concerns both the quality of the production and the control in operation of the products.

In the company there is staff qualified and certified for Non-Destructive Test according to standard UNI

EN ISO 9712: 2012: 2 operators for VT Level III and 2 operators for VT Level II.

Page 5: LIQUID PENETRANT TESTS (PT ) · The penetration of the liquid inside a discontinuity occurs by capillarity and not by gravity. This prerogative, which is the basis of all the control

DIMENSIONAL CHECKS

Dimensional check is carried out both with traditional instruments, through internal, external and depth micrometers, digital gauges, digital gauges for depth and the use of parallel Johnson-type flat blocks.

For parts of large dimensions or with particularly complicated geometries, the company owns 3D laser

equipment:

• FARO Arm Edge measuring arm

• ION FARO Laser Tracker

For roughness check, the company uses portable roughness testers Surf Test SJ-210 Mitutoyo.

All the instrumentation is subjected to periodic calibration in-house or in accredited laboratories.

The personnel working on these instruments is highly qualified and specialized.