    Operations, Administration,

    Maintenance & Provisioning Guide

    BTI Systems

    50 Northside Road

    Ottawa, ON K2H 5Z6

    (613) 248-9154

    www.btisystems.com

    Product Release 6.2

    Document Version 01

    January 2008

    Part Number BP1A74FB

    STANDARD

    http://www.btiphotonics.com/http://www.btiphotonics.com/
  • 7/23/2019 Oamp Guide 6-2 Stand 01

    2/533

    Copyright 2003-2008 BTI Systems All rights reserved.

    The information contained herein is the property of BTI Systems and is strictly confidential. Except as expressly authorized inwriting by BTI Systems, the holder shall keep all information contained herein confidential, shall disclose the information only to itsemployees with a need to know, and shall protect the information, in whole or in part, from disclosure and dissemination to thirdparties with the same degree of care it uses to protect its own confidential information, but with no less than reasonable care.Except as expressly authorized in writing by BTI Systems, the holder is granted no rights to use the information contained herein.

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    3/533

    Product Release 6.2 STANDARD iii

    Preface xiii

    Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii

    Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv

    Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxi

    New features and upcoming product enhancements . . . . . . . . . . . . . . . . . . . . . . . . . .xxxii

    Organization of the Netstender documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxv

    Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxviii

    Obtaining documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxix

    World Wide Web . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxix

    Product documentation CD-ROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxix

    Ordering documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxix

    Documentation feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxixObtaining technical support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxix

    1.0 Netstender overview 1-1

    1.1 Netstender features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

    1.2 Netstender design values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4

    1.3 Netstender technology features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

    1.3.1 Optical amplification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

    1.3.2 Optical multiplexing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6

    1.3.3 Optical signal conditioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7

    1.3.4 Optical Supervisory Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7

    1.3.5 Wavelength conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8

    1.3.6 Muxponder modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-81.3.7 Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9

    2.0 Netstender state management 2-1

    2.1 Entity management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2

    2.2 Telcordia state model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2

    Contents

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    4/533

    ivNetstender OAM&P Guide Document Version 01

    Contents

    2.3 Telcordia state attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17

    2.3.1 PST and PSTQ values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17

    2.3.1.1 IS In service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17

    2.3.1.2 OOS Out of service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18

    2.3.1.3 NR Normal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18

    2.3.1.4 ANR Abnormal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18

    2.3.1.5 AU Autonomous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18

    2.3.1.6 MA Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19

    2.3.1.7 MAANR Management and abnormal . . . . . . . . . . . . . . . . . . . . . . . . . 2-19

    2.3.1.8 AUMA Autonomous and management. . . . . . . . . . . . . . . . . . . . . . . . 2-20

    2.3.2 SST values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20

    2.3.2.1 AINS Automatic in service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20

    2.3.2.2 COMM Communication error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

    2.3.2.3 FLT Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

    2.3.2.4 FRCD Forced . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

    2.3.2.5 LKDO Locked out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

    2.3.2.6 LPBK Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-212.3.2.7 MEA Mismatch of equipment and attributes. . . . . . . . . . . . . . . . . . . . 2-21

    2.3.2.8 MT Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

    2.3.2.9 SGEO Supporting entity outage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21

    2.3.2.10 STDBY Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22

    2.3.2.11 SWDL Software download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22

    2.3.2.12 UEQ Unequipped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22

    2.3.2.13 WRK Working . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22

    2.4 Equipment state management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-23

    2.5 Amplifier entity state management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-24

    2.6 Wavelength conversion transceiver port state management. . . . . . . . . . . . . . . . . 2-24

    2.7 State management behavior interactions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25

    2.8 State management provisioning interactions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-252.9 State change reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25

    2.10 Supporting and supported physical entities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26

    2.11 Fault reporting interactions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26

    3.0 Operating the Netstender 3-1

    3.1 Starting up the system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

    3.1.1 Communication ports on the Netstender . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

    3.2 Establishing a TL1 session using Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3

    3.2.1 Method One: Connecting through the management LAN . . . . . . . . . . . . . . . . 3-5

    3.2.2 Method Two: Connecting through the craft LAN port . . . . . . . . . . . . . . . . . . . . 3-6

    3.2.3 Changing the IP address and mask from the default . . . . . . . . . . . . . . . . . . . . 3-8

    3.2.4 Changing the default gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9

    3.3 Establishing a TL1 session using RS-232. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10

    3.3.1 RS-232 serial communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12

    3.4 Establishing a TL1 session using a Hayes modem. . . . . . . . . . . . . . . . . . . . . . . . 3-14

    3.5 Connecting management systems to Netstender ports. . . . . . . . . . . . . . . . . . . . . 3-16

    3.5.1 Netstender SNMP support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    5/533

    Product Release 6.2 STANDARD v

    Contents

    3.5.2 Modes of TL1 operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17

    3.6 Establishing an expansion shelf interface CLI session . . . . . . . . . . . . . . . . . . . . . 3-18

    3.6.1 Connecting through the craft LAN port on an ESI circuit pack . . . . . . . . . . . . 3-19

    3.6.2 Connecting through the craft serial port on an ESI circuit pack . . . . . . . . . . . 3-203.7 Understanding the audible and visual indications . . . . . . . . . . . . . . . . . . . . . . . . . 3-21

    3.7.1 Location of Netstender 2060 main shelf and system alarms . . . . . . . . . . . . . 3-21

    3.7.2 Location of Netstender 2060 expansion shelf alarms . . . . . . . . . . . . . . . . . . 3-21

    3.7.3 Location of Netstender 1030 shelf and system alarms . . . . . . . . . . . . . . . . . 3-22

    3.7.4 Netstender system alarm LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22

    3.7.5 Audible alarms and office alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23

    3.7.6 Shelf and circuit pack LED behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23

    3.7.6.1 Netstender 2060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23

    3.7.6.2 Netstender 1030 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24

    3.7.7 Alarm cutoff and lamp test button. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24

    3.7.8 Alarm masking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24

    3.8 TL1 identifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25

    3.8.1 Network element SID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25

    3.8.2 Subordinate elements AID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25

    3.9 Events, conditions and alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29

    3.9.1 Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29

    3.9.2 Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29

    3.9.3 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29

    3.10 Circuit pack detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30

    3.10.1 System responses for common equipment circuit packs . . . . . . . . . . . . . . . 3-31

    3.10.2 System responses for various circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . 3-32

    3.11 In-service shelf reconfiguration of a Netstender 2060 . . . . . . . . . . . . . . . . . . . . . 3-34

    3.12 Shutting down the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-37

    4.0 Installing optional Netstender circuit packs 4-14.1 Installing optical amplifier circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

    4.2 Installing optical supervisory channel circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . 4-7

    4.3 Installing wavelength conversion circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8

    4.3.1 Installing SFP transceivers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12

    4.3.2 Installing 10G Wavelength Regenerator XFP transceivers . . . . . . . . . . . . . . 4-15

    4.4 Installing Muxponder circuit packs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18

    4.5 Installing optical add-drop module circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20

    4.6 Installing optical component tray circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24

    4.7 Installing multiplexer/demultiplexer circuit packs. . . . . . . . . . . . . . . . . . . . . . . . . . 4-27

    4.8 Installing DWDM bi-directional coupler/splitter circuit packs . . . . . . . . . . . . . . . . . 4-31

    4.9 Installing dispersion compensation module circuit packs . . . . . . . . . . . . . . . . . . . 4-33

    4.10 Installing filler circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-37

    5.0 Connecting circuit packs 5-1

    5.1 Amplifier configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    6/533

    viNetstender OAM&P Guide Document Version 01

    Contents

    5.1.1 Connecting fibers between an OLAM and a DCM . . . . . . . . . . . . . . . . . . . . . . 5-2

    5.2 OADM configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3

    5.2.1 Basic cascading of OADMs to provide mux/demux functionality . . . . . . . . . . . 5-3

    5.2.2 OADM survivability of upstream and downstream traffic . . . . . . . . . . . . . . . . . 5-45.2.3 Cascading OADMs for survivability and future growth . . . . . . . . . . . . . . . . . . . 5-6

    6.0 Connecting expansion shelves 6-1

    6.1 Netstender 2060 expansion shelves overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2

    6.2 Connecting local expansion shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3

    6.3 Connecting remote expansion shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4

    7.0 Provisioning the Netstender 7-1

    7.1 How Netstender provisioning works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2

    7.1.1 Auto provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2

    7.1.1.1 Controlling auto provisioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2

    7.1.1.2 Amplifier circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-37.1.1.3 OSC circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3

    7.1.1.4 Active mux/demux circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3

    7.1.1.5 Passive circuit packs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4

    7.1.1.6 Wavelength conversion circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4

    7.1.1.7 Wavelength manager ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4

    7.1.1.8 Muxponder circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5

    7.1.1.9 Muxponder circuit pack ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6

    7.1.1.10 Expansion shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6

    7.1.2 Auto de-provisioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6

    7.1.2.1 Controlling auto de-provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6

    7.1.2.2 Expansion shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7

    7.1.3 Pre-provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8

    7.1.4 Automatic in service secondary state. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-87.1.4.1 ENT commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9

    7.1.4.2 Forcing a transition from the AINS state to the IS state . . . . . . . . . . . . . . 7-9

    7.1.4.3 Viewing AINS timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9

    7.1.4.4 MSCP or MSI restart or replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9

    7.1.4.5 Retrieving the faults against equipment in the AINS state . . . . . . . . . . . . 7-9

    7.2 Hierarchical organization of Netstender components . . . . . . . . . . . . . . . . . . . . . . 7-10

    7.2.1 Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11

    7.2.2 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11

    7.2.3 Equipmentshelves and circuit packs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11

    7.2.3.1 Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11

    7.2.3.2 Common equipment circuit packs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11

    7.2.3.3 Provisionable slots for application circuit packs . . . . . . . . . . . . . . . . . . . 7-127.2.4 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13

    7.2.5 Supporting and supported relationships. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13

    7.3 Designating names and IDs to system components . . . . . . . . . . . . . . . . . . . . . . . 7-14

    7.4 System provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-15

    7.4.1 Network element, site, time zone, and system identification code . . . . . . . . . 7-15

    7.4.1.1 Editing the network element, site, and time zone . . . . . . . . . . . . . . . . . . 7-15

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    7/533

    Product Release 6.2 STANDARD vii

    Contents

    7.4.1.2 Setting the system identification code. . . . . . . . . . . . . . . . . . . . . . . . . . . 7-16

    7.4.1.3 Retrieving the network element, site, time zone, and uptime . . . . . . . . . 7-17

    7.4.1.4 Retrieving the vendor, model, NE type and software version . . . . . . . . . 7-17

    7.4.2 Date and time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-18

    7.4.2.1 Editing the date and time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-18

    7.4.2.2 Editing the date and time during a daylight-saving-time transition . . . . . 7-19

    7.4.2.3 Retrieving the system identifier, date, and time . . . . . . . . . . . . . . . . . . . 7-20

    7.4.3 IP address parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-21

    7.4.3.1 Editing the IP address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-21

    7.4.3.2 Retrieving the IP address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-22

    7.4.4 Craft serial interface parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23

    7.4.4.1 Editing the craft serial port information . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23

    7.4.4.2 Retrieving the craft serial port information . . . . . . . . . . . . . . . . . . . . . . . 7-24

    7.5 Expansion shelf provisioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-25

    7.5.1 System requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-25

    7.5.1.1 Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-25

    7.5.2 Expansion shelf provisioning rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-267.5.2.1 Basic provisioning tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-26

    7.5.2.2 Auto creation of expansion shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-26

    7.5.2.3 Expansion shelf LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-26

    7.5.2.4 Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-26

    7.5.3 Reconfiguring expansion shelves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27

    7.5.4 Re-purposing expansion shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27

    7.5.5 Expansion shelf command line interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27

    7.6 Equipment provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-28

    7.6.1 Entering new equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-28

    7.6.2 Editing equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-29

    7.6.3 Removing equipment from service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-30

    7.6.4 Restoring equipment to service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-31

    7.6.5 Retrieving equipment attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-32

    7.6.6 Retrieving an equipment inventory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-33

    7.6.7 Deleting equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-35

    7.7 Optical amplifier provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-36

    7.7.1 Provisioning an optical amplifier. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-37

    7.7.2 Modifying the definable parameters of an optical amplifier . . . . . . . . . . . . . . 7-45

    7.7.3 Removing an optical amplifier from service . . . . . . . . . . . . . . . . . . . . . . . . . . 7-47

    7.7.4 Restoring an optical amplifier to service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-50

    7.7.4.1 Using the OPR-OBR-HTSO command . . . . . . . . . . . . . . . . . . . . . . . . . . 7-53

    7.7.5 Retrieving optical amplifier settings and status . . . . . . . . . . . . . . . . . . . . . . . 7-54

    7.7.6 Deleting an optical amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-63

    7.8 OSC provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-66

    7.9 Wavelength conversion provisioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-677.9.1 Provisioning wavelength conversion circuit pack equipment . . . . . . . . . . . . . 7-68

    7.9.2 Provisioning transceiver ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-70

    7.9.2.1 Retrieving a manufacturers SFP/XFP transceiver inventory information 7-71

    7.9.2.2 Provisioning transceiver ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-75

    7.9.2.3 Implementing advanced provisioning features . . . . . . . . . . . . . . . . . . . . 7-81

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    8/533

    viiiNetstender OAM&P Guide Document Version 01

    Contents

    7.9.2.4 Modifying the definable parameters of a transceiver port . . . . . . . . . . . . 7-83

    7.9.2.5 Removing a transceiver port from service . . . . . . . . . . . . . . . . . . . . . . . 7-85

    7.9.2.6 Restoring a transceiver to service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-87

    7.9.2.7 Retrieving transceiver attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-88

    7.9.2.8 Deleting a transceiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-92

    7.9.3 Provisioning cross-connects on a Wavelength Conversion circuit pack. . . . . 7-93

    7.9.3.1 Provisioning cross-connects on a Wavelength Conversion circuit pack . 7-93

    7.9.3.2 Retrieving cross-connect port information from a Wavelength Conversion

    circuit pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-97

    7.9.3.3 Deleting a cross-connect on a Wavelength Conversion circuit pack . . . 7-98

    7.9.4 Provisioning protection groups on a Wavelength Conversion circuit pack . . . 7-99

    7.9.4.1 How protection switching works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-100

    7.9.4.2 Provisioning rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-100

    7.9.4.3 Example scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-101

    7.9.4.4 Provisioning a protection group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-103

    7.9.4.5 Modifying the definable parameters of a protection group . . . . . . . . . . 7-104

    7.9.4.6 Retrieving protection group parameters . . . . . . . . . . . . . . . . . . . . . . . . 7-1047.9.4.7 Deleting a protection group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-105

    7.10 2-Port GE Muxponder provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-106

    7.10.1 Provisioning 2-Port GE Muxponder circuit pack equipment . . . . . . . . . . . . 7-107

    7.10.2 Provisioning synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-108

    7.10.2.1 Provisioning the timing mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-109

    7.10.2.2 Retrieving timing-mode information . . . . . . . . . . . . . . . . . . . . . . . . . . 7-110

    7.10.2.3 Provisioning the timing reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-111

    7.10.2.4 Retrieving timing-reference information . . . . . . . . . . . . . . . . . . . . . . . 7-113

    7.10.3 Provisioning Fast Ethernet client side ports . . . . . . . . . . . . . . . . . . . . . . . . 7-114

    7.10.3.1 Provisioning an FE client side port . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-114

    7.10.3.2 Modifying the provisionable parameters of an FE client side port. . . . 7-116

    7.10.3.3 Retrieving FE client side port attributes . . . . . . . . . . . . . . . . . . . . . . . 7-117

    7.10.3.4 Deleting an FE client side port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1197.10.4 Retrieving a manufacturers SFP transceiver inventory . . . . . . . . . . . . . . . 7-120

    7.10.5 Provisioning gigabit Ethernet client side ports . . . . . . . . . . . . . . . . . . . . . . 7-123

    7.10.5.1 Provisioning a GE client side port . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-124

    7.10.5.2 Implementing advanced provisioning features . . . . . . . . . . . . . . . . . . 7-126

    7.10.5.3 Modifying the provisionable parameters of a GE client side port . . . . 7-128

    7.10.5.4 Removing a GE client side port from service . . . . . . . . . . . . . . . . . . . 7-129

    7.10.5.5 Restoring a GE client side port to service. . . . . . . . . . . . . . . . . . . . . . 7-130

    7.10.5.6 Retrieving GE client side port attributes . . . . . . . . . . . . . . . . . . . . . . . 7-131

    7.10.5.7 Deleting a GE client side port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-134

    7.10.6 Provisioning OC-48 line side ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-135

    7.10.6.1 Provisioning an OC-48 line side port . . . . . . . . . . . . . . . . . . . . . . . . . 7-135

    7.10.6.2 Enabling threshold crossing alarms on OC-48 line side ports . . . . . . 7-139

    7.10.6.3 Modifying the provisionable parameters of an OC-48 line side port . . 7-139

    7.10.6.4 Removing an OC-48 line side port from service . . . . . . . . . . . . . . . . . 7-141

    7.10.6.5 Restoring an OC-48 line side port to service . . . . . . . . . . . . . . . . . . . 7-142

    7.10.6.6 Retrieving OC-48 line side port attributes . . . . . . . . . . . . . . . . . . . . . . 7-143

    7.10.6.7 Deleting an OC-48 line side port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-146

    7.10.7 Provisioning STM-16 line side ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-148

    7.10.7.1 Provisioning an STM-16 line side port . . . . . . . . . . . . . . . . . . . . . . . . 7-148

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    9/533

    Product Release 6.2 STANDARD ix

    Contents

    7.10.7.2 Enabling threshold crossing alarms on STM-16 line side ports . . . . . 7-151

    7.10.7.3 Modifying the provisionable parameters of an STM-16 line side port . 7-152

    7.10.7.4 Removing an STM-16 line side port from service . . . . . . . . . . . . . . . . 7-153

    7.10.7.5 Restoring an STM-16 line side port to service . . . . . . . . . . . . . . . . . . 7-154

    7.10.7.6 Retrieving STM-16 line side port attributes. . . . . . . . . . . . . . . . . . . . . 7-156

    7.10.7.7 Deleting an STM-16 line side port. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-159

    7.10.8 Retrieving Virtual Concatenation Group attributes . . . . . . . . . . . . . . . . . . . 7-161

    7.10.9 Provisioning cross-connections on a Muxponder circuit pack . . . . . . . . . . 7-165

    7.10.9.1 Provisioning a cross-connection on a Muxponder circuit pack . . . . . . 7-166

    7.10.9.2 Retrieving cross-connection information from a Muxponder circuit pack . 7-

    170

    7.10.9.3 Deleting a cross-connection on a Muxponder circuit pack . . . . . . . . . 7-172

    7.10.10 Provisioning protection switching on a Muxponder circuit pack . . . . . . . . 7-173

    7.10.10.1 How protection switching works . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-173

    7.10.10.2 Protection switching rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-174

    7.10.10.3 Operating a protection switch using an STS1 path facility object . . . 7-174

    7.10.10.4 Releasing an STS1 path facility object protection switch . . . . . . . . . 7-1757.10.10.5 Operating a protection switch using a VC4 path facility object . . . . . 7-175

    7.10.10.6 Releasing a VC4 path facility object protection switch . . . . . . . . . . . 7-176

    7.11 Provisioning active mux/demux ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-177

    7.12 Provisioning non-powered circuit pack ports . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-178

    7.12.1 Modifying the parameters of a port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-179

    7.12.2 Retrieving the parameters of a port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-182

    8.0 Netstender performance monitoring 8-1

    8.1 Understanding performance monitoring data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2

    8.1.1 PM parameter history. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3

    8.1.2 PM parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5

    8.1.2.1 Optical amplifier modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-68.1.2.2 Optical Supervisory Channel modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-8

    8.1.2.3 Transceiver ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9

    8.1.2.4 2.5G Wavlength Manager modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-10

    8.1.2.5 10G Wavelength Regenerator modules . . . . . . . . . . . . . . . . . . . . . . . . . 8-12

    8.1.2.6 2-Port GE Muxponder modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-16

    8.1.2.7 DWDM active multiplexer/demultiplexer modules. . . . . . . . . . . . . . . . . . 8-19

    8.1.3 Bin validity qualifiers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-19

    8.1.4 Threshold crossing alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-20

    8.2 Retrieving performance monitoring data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-22

    8.2.1 PM retrieval command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-22

    8.2.1.1 Other PM retrieval commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-23

    8.2.2 Retrieving current PM bins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-23

    8.2.2.1 Example one . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-238.2.2.2 Example two . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-25

    8.2.3 Retrieving historical PM bins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-25

    8.2.3.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-25

    9.0 Administering the Netstender 9-1

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    10/533

    xNetstender OAM&P Guide Document Version 01

    Contents

    9.1 Security management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2

    9.1.1 Security user profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2

    9.1.2 Security authorization levels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2

    9.1.3 Security default userid and password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2

    9.1.4 Security commands and authorization level required. . . . . . . . . . . . . . . . . . . . 9-3

    9.1.5 Security commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-9

    9.1.5.1 Creating a userid, password and privilege for a user . . . . . . . . . . . . . . . . 9-9

    9.1.5.2 Modifying passwords and privileges . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10

    9.1.5.3 Deleting a userid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-11

    9.1.5.4 Inhibiting a userid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-12

    9.1.5.5 Allowing a userid. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-13

    9.1.5.6 Retrieving a list of active users and cancelling a users TL1 session . . . 9-14

    9.1.6 Common user commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-15

    9.1.6.1 Logging in to a TL1 session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-15

    9.1.6.2 Cancelling a TL1 session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-16

    9.1.6.3 Editing a users own password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-17

    9.1.6.4 Retrieving a users own security credentials. . . . . . . . . . . . . . . . . . . . . . 9-189.2 Log management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-19

    9.2.1 Log management history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-19

    9.2.2 About logs on the Netstender. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-19

    9.2.3 Standard log commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-21

    9.2.3.1 Retrieving logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-21

    9.2.3.2 Stopping logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-25

    9.2.3.3 Starting logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-26

    9.2.3.4 Initializing logs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-27

    9.2.3.5 Retrieving log attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-28

    9.2.4 Security log commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-29

    9.2.4.1 Retrieving security log attributes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-29

    9.2.4.2 Setting security log attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-30

    9.3 Protection switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-31

    9.3.1 Protection switching severity levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-31

    9.3.2 User-invoked protection switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-32

    9.4 Software load management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-34

    9.5 Database backup and restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-35

    9.5.1 Database backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-35

    9.5.2 Database restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-38

    9.6 Restarting a circuit pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-45

    9.7 Performing a loopback test through an SFP, XFP or MSA transceiver on a Wavelength

    Conversion circuit pack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-47

    9.7.1 How to tell when an SFP, XFP or MSA transceiver port on a Wavelength

    Conversion circuit pack is in loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-49

    9.7.1.1 RTRV-XCVR command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-49

    9.7.1.2 RTRV-COND-ALL command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-49

    9.8 Performing a loopback test through a port on a Muxponder circuit pack . . . . . . . 9-50

    9.8.2 How to tell when a port on a Muxponder circuit pack is in loopback . . . . . . . 9-53

    9.8.2.1 RTRV-GE, RTRV-OC48, or RTRV-STM16 command. . . . . . . . . . . . . . . 9-53

    9.8.2.2 RTRV-COND-ALL command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-53

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    11/533

    Product Release 6.2 STANDARD xi

    Contents

    9.9 Configuration profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-54

    9.9.1 Creating configuration profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-55

    9.9.1.1 Creating a profile online . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-55

    9.9.1.2 Creating a profile offline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-56

    9.9.2 Importing profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-57

    9.9.3 Applying profiles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-58

    9.9.4 Edit, view or delete profiles online . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-59

    10.0 Replacing circuit packs 10-1

    10.1 Common equipment circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-2

    10.1.1 Netstender 2060 common equipment circuit packs . . . . . . . . . . . . . . . . . . . 10-2

    10.1.1.1 Netstender 2060 common equipment circuit pack locations. . . . . . . . . 10-2

    10.1.1.2 Netstender 2060 Cooling Unit circuit pack . . . . . . . . . . . . . . . . . . . . . . 10-3

    10.1.1.3 Netstender 2060 Main Shelf Interface circuit pack . . . . . . . . . . . . . . . . 10-6

    10.1.1.4 Netstender 2060 Expansion Shelf Interface circuit pack. . . . . . . . . . . . 10-8

    10.1.1.5 Netstender 2060 Multiport System Control Processor circuit pack . . . 10-10

    10.1.2 Netstender 1030 common equipment circuit packs . . . . . . . . . . . . . . . . . . 10-1410.1.2.1 Netstender 1030 common equipment circuit pack locations. . . . . . . . 10-14

    10.1.2.2 Netstender 1030 Cooling Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-15

    10.1.2.3 Netstender 1030 System Control Processor circuit pack . . . . . . . . . . 10-17

    10.2 Optical supervisory channel circuit pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-20

    10.2.1 OSC Coupler/Splitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-23

    10.3 Wavelength conversion circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-26

    10.3.1 SFP transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-29

    10.3.2 10G Wavelength Regenerator XFP transceivers . . . . . . . . . . . . . . . . . . . . 10-33

    10.4 Muxponder circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-37

    10.5 Optical amplifier circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-40

    10.6 Dispersion compensating module circuit packs. . . . . . . . . . . . . . . . . . . . . . . . . 10-45

    10.7 Filler circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-48

    10.8 Multiplex/demultiplex module circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-50

    10.9 Optical add-drop module circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-54

    10.10 DWDM bi-directional coupler/splitter circuit packs . . . . . . . . . . . . . . . . . . . . . 10-57

    Appendix A: Optical back reflection safety feature A-1

    A.1 Principle of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2

    A.1.1 Next generation OBA and SBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3

    A.2 Querying back-reflection photo-detector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4

    Appendix B: Working with the configuration database B-1

    B.1 Configuration database. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2B.1.1 Database backup precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3

    B.2 Automatic backup process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3

    B.3 Impact of circuit pack replacement on the database. . . . . . . . . . . . . . . . . . . . . . . . B-4

    B.3.1 Recommendations when replacing circuit packs. . . . . . . . . . . . . . . . . . . . . . . B-4

    B.4 Automatic restore process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    12/533

    xiiNetstender OAM&P Guide Document Version 01

    Contents

    B.4.1 System running current software, replace MSCP with a unit loaded with the

    current software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5

    B.4.2 System running current software, replace MSCP with a unit loaded with an earlier

    or later software load. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5

    B.4.3 System running current software, cycle power . . . . . . . . . . . . . . . . . . . . . . . . B-5

    B.5 Manual backup process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6

    B.6 Manual restore process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7

    B.7 Pre-provisioning circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8

    B.8 Preconfigured MSCP scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8

    B.9 Replacing a failed MSCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9

    B.10 Replacing failed circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9

    B.11 Clearing the database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9

    Appendix C: Universal connectors C-1

    C.1 About universal connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2

    C.2 Cleaning universal connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3

    Appendix D: ESI command line interface D-1

    D.1 Expansion shelf interface access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-2

    D.2 ESI main menu display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-2

    D.3 ESI shelf configuration display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3

    D.4 ESI SFP inventory display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-5

    D.5 ESI SFP alarm status display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-7

    D.6 ESI SFP digital diagnostics data display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-8

    Appendix E: Contacting BTI support E-1

    E.1 Before you contact BTI support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1E.2 How to collect required information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-2

    E.2.1 Obtaining information locally . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-2

    E.2.2 Obtaining information remotely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3

    E.2.2.1 Netstender product release number . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3

    E.2.2.2 Circuit pack information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4

    E.2.2.3 SFP and XFP transceiver information . . . . . . . . . . . . . . . . . . . . . . . . . . E-6

    E.2.2.4 Detailed description of the problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-8

    E.3 How to contact BTI support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-9

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    13/533

    Product Release 6.2 STANDARD xiii

    Preface

    This section explains who should read the OAM&P Guide, how the document isorganized, related documentation, document conventions, how to obtain orderdocumentation and how to obtain technical support.

    Audience

    This guide is primarily intended for technicians and network operation center(NOC) staff. For product description, planning, commissioning, installation, alarmclearing, troubleshooting or Transaction Language 1 (TL1) information see

    Organization of the Netstender documentation.

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    14/533

    xivNetstender OAM&P Guide Document Version 01

    Preface

    Revision History

    The following table tracks the revision history for each product releasemodification to this document.

    Document Revision History

    Release Date Modifications

    1.0 March 2003 This document is released.

    1.1 August 2003 Added the Revision History to the Preface of this document.

    Added the following power monitor tap circuit packs: PMT1 andPMT2.

    Added the SMF 40 km dispersion compensating fiber module circuitpack.

    Added section 4.11, Installing power monitor taps.

    Added the following new equipment AIDs: PMT1, PMT2, andSMF40.

    Added section 4.8, Power monitor tap provisioning.

    Added the PM Parameter History to the Netstender performancemonitoring chapter in this document.

    Added the operator interrupt q to the RTRV-LOG command.

    Added the LASERSTATUS parameter in the RTRV-OA message.

    Added section section 10.10, Power monitor tap circuit packs.

    Added Appendix E: Contacting BTI support.

    Updated the circuit pack state transition diagram.

    Updated Figure 3-11, Netstender 2060 LED behavior.

    Updated the content for sections 7.1, How Netstender provisioningworks, 7.2, Hierarchical organization of Netstender components,

    7.3, Designating names and IDs to system components, and 7.7,Optical amplifier provisioning.

    Updated section 9.1.4, Security commands and authorization levelrequired.

    Removed the INVK-SCP-LOAD command that is now replaced bythe INVK-SCP-RELNUM command.

    Removed the LASERMDE parameter from the following commands:ED-OA, ENT-OA, and RTRV-OA.

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    15/533

    Product Release 6.2STANDARDxv

    Preface

    2.1 March 2004 The former Optical Link System (OLS) is rebranded as theNetstender. In general, former occurrences of OLS are replaced bythe term NETSTENDER.

    Added the following equipment to all applicable descriptions andprocedures:- 1-, 2- and 4-Channel DWDM OADMs- 4- and 32-Channel DWDM Multiplexer/Demultiplexers- 1-Channel CWDM OADMs- 8-Channel CWDM Multiplexer/Demultiplexer- CWDM and DWDM Splitter/Combiner- Blue, Red and Wideband CWDM Line Amplifiers- Optical Supervisory Channel- Single-channel Pre-Amplifier

    Added the following shelf configuration (SHCONF) values for themessage syntax of the RTRV-INV command: 4-SLOT and 5-SLOT.

    Added additional state transitions to the Circuit Pack State TransitionDiagram in Chapter 2.

    Added the GATEWAY parameter to the ED-SYS and RTRV-SYScommands.

    Added the following LAN AIDs: IP-NMS and IP-CRAFT.

    Added D1ADM, D2ADM, D4ADM, D32MD, C1ADM, C8MD, CDSC,CLAB, CLAR, CLAW, OSC and SPA as valid equipment to allapplicable descriptions and procedures.

    Added replacement procedures for the Multiplex/Demultiplex circuitpacks.

    Add CWDM Line Amplifier Blue, CWDM Line Amplifier Red, CWDMLine Amplifier Wideband and DWDM Single Channel Pre-Amplifieras valid amplifier types for the optical amplifier circuit pack

    replacement procedure.The following PM parameters are added:

    EFFGAIN_BEFFGAIN_ROPR_BOPR_ROPT_BOPT_RINNONUNICASTINUNICASTIPFWDDATAIPINRXIPOUTREQOUTNONUNICASTOUTINICAST

    The following PM parameters are changed:

    PL1TEMP changes to L1TEMPPL2TEMP changes to L2TEMPPL1CUR changes to L1CURPL2CUR changes to L2CURPL1PWR changes to L1PWRPL2PWR changes to L2PWR

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    16/533

    xviNetstender OAM&P Guide Document Version 01

    Preface

    2.1 March 2004 Changed the name Graphical Craft Interface (GCI) to NetstenderNode Controller (NNC).

    Changed ED-DAT command so that either the date or timeparameters can now be edited separately without the need to specifyboth parameters.

    Changed the date field for all TL1 headers from YYYY-MM-DD toYY-MM-DD (for example, 2004-12-15 becomes 04-12-15).

    Removed the GATEWAY parameter from the ED-IP and RTRV-IPcommands.

    Removed the SHCONF parameter from the following commands:ED-EQPT, ENT-EQPT and RTRV-EQPT.

    Removed the following log commands: ALW-LOG-SECU,INH-LOG-SECU, and INIT-LOG-SECU.

    Note:For some special customer loads, refer to the includedaddendum for specific TL1 modifications to the REPT^ALM andREPT^EVT message formats.

    2.1 April 2004 Minor corrections and updates are incorporated to the document.

    2.1 May 2004 Added a description of the effects the INIT-SYS command has on anSCP circuit pack.

    Added the Optical Component Tray (OCT) circuit pack installationprocedure.

    Added the Optical Component Tray (OCT) circuit pack replacementprocedure.

    ","

    2.2 August 2004 Added the following equipment to all applicable descriptions andprocedures:- Single-channel/Sub-band Booster Amplifier

    Added the following commands: DLT-ARP-PROXY,ENT-ARP-PROXY, OPR-OBR-HTSO, RTRV-ARP-ALL, andRTRV-ARP-PROXY TL1 commands.

    Added a section called Using the OPR-OBR-HTSO command.

    Increased to number of concurrent TL1 sessions to 24 and thenumber of unique userids to 50.

    Restricted the number of active TL1 sessions per userid to one.

    Modified the REPT^RMV and REPT^RST commands by changingthe format of , to :.

    Updated the Telcordia state model information in Chapter 2.

    2.2 Sept. 2004 Updated the In-service shelf reconfiguration procedure.

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    17/533

    Product Release 6.2STANDARDxvii

    Preface

    2.3 Dec. 2004 Added the following equipment to all applicable descriptions andprocedures:

    - Dispersion Compensating Fiber Module 30 km- 2-Port Connectorized Power Monitor Tap 1%- 4-Port Connectorized Power Monitor Tap 1%- 2-Port Connectorized Power Monitor Tap 2%- 4-Port Connectorized Power Monitor Tap 2%- Single ASE Noise Filter- SMF Single Channel DCM 40 km- SMF Single Channel DCM 60 km- SMF Single Channel DCM 80 km- System Control Processor (with 1 Expansion Shelf Connector)

    Added Appendix A: Universal connectors.

    Modified the restrictions of a userid and password from being the

    same string. For example, the userid george cannot have apassword of george.

    3.0 Dec. 2004 Added the following equipment to all applicable descriptions andprocedures:

    - Netstender 1030 Shelf- Netstender 1030 System Control Processor- Netstender 1030 Cooling Unit

    Added a prerequisite to the Database Restore procedure inChapter 6.

    Modified the use of the CTAG in all TL1 commands. The CTAG isnow optional.

    3.1 April 2005 Added LPBK as a valid secondary state.

    Added a procedure for installing wavelength conversion circuitpacks.

    Added provisioning information for the following:- wavelength conversion circuit packs- SFP transceiver ports- Cross-connects

    Added the following new performance monitoring (PM) parameters:- LBC- SUPPLY- TEMP

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    18/533

    xviiiNetstender OAM&P Guide Document Version 01

    Preface

    3.1 contd April 2005 Added the following new TL1 commands to the table in Chapter 9.0,Administering the Netstender:- DLT-CRS-XCVR- DLT-XCVR- ED-XCVR- ENT-CRS-XCVR- ENT-XCVR- OPR-LPBK-TST- RLS-LPBK-TST- RMV-XCVR- RST-XCVR- RTRV-ALM-XCVR- RTRV-COND-XCVR- RTRV-CRS-XCVR- RTRV-PM-XCVR

    - RTRV-XCVRAdded the following replacement procedures:- Wavelength translator/regenerator circuit packs- SFP transceivers

    Removed the BP1A26AA and BP1A26BA Power Monitor Tap circuitpacks as their manufacture is discontinued.

    3.1 May 2005 Added a restriction to the procedure for installing wavelengthtranslator/regenerator circuit packs.

    3.1 June 2005 Added the Optical Line Amplifier (OLA) and Optical Line Amplifierwith Mid-stage access (OLAM) as being supported by theOPR-OBR-HTSO command.

    3.1.1 July 2005 Updated the PROTOCOL parameter for the ED-XCVR, ENT-XCVRand RTRV-XCVR commands to include the following values: STM1,STM4 and STM16.

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    19/533

    Product Release 6.2STANDARDxix

    Preface

    4.1 May 2006 Added the following chapters:- 5.0, Connecting circuit packs- 6.0, Connecting expansion shelves

    Added the following appendices:- Appendix A: Optical back reflection safety feature- Appendix B: Working with the configuration database- Appendix D: ESI command line interface

    Added the following sections:- 3.6, Establishing an expansion shelf interface CLI session- 9.9, Configuration profiles

    Added a default backup file name to the INVK-DB-BKUP commandin Chapter 9.0, Administering the Netstender.

    Added the following commands to section 9.1.4, Securitycommands and authorization level required:

    - CMMT-ES- DLT-FFP-XCVR- ED-AMD- ED-FFP-XCVR- ENT-FFP-XCVR- INIT-REG-XCVR- OPR-PROTNSW-XCVR- RLS-PROTNSW-XCVR- RMV-AMD- RST-AMD- RTRV-ALM-AMD- RTRV-AMD- RTRV-AUTOD- RTRV-COND-AMD- RTRV-FFP-XCVR

    - RTRV-PM-AMD- RTRV-TH-XCVR- SET-TH-XCVR

    Divided Chapter 3 into two separate chapters:- 3.0, Operating the Netstender- 4.0, Installing optional Netstender circuit packs

    Updated the authorization required to ALL for the followingcommands: RTRV-ALM-SECU and RTRV-COND-SECU.

    Updated the hardware illustrations to reflect the latest designimprovements to the circuit packs.

    5.1 Dec. 2006 Added the following sections:- the section on Compliance in the Preface- 7.1.1.7, Wavelength manager ports- Appendix E: Transport overhead bytes for wavelength manager

    Updated the following sections:- 1.3.5, Wavelength conversion- 2.4, Equipment state management- 2.6, Wavelength conversion transceiver port state management- 3.7.5, Audible alarms and office alarms- 3.8.2, Subordinate elements AID- 4.3, Installing wavelength conversion circuit packs- 4.3.1, Installing SFP transceivers

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    20/533

    xxNetstender OAM&P Guide Document Version 01

    Preface

    5.1(contd)

    Dec. 2006 - 7.1.1.6, Wavelength conversion circuit packs- 7.9.1, Provisioning wavelength conversion circuit pack equipment- 7.9.2, Provisioning transceiver ports- 7.9.2.1, Retrieving a manufacturers SFP/XFP transceiverinventory information- 7.9.2.2, Provisioning transceiver ports- 7.9.2.3, Implementing advanced provisioning features- 7.9.2.4, Modifying the definable parameters of a transceiver port- 7.9.2.5, Removing a transceiver port from service- 7.9.2.6, Restoring a transceiver to service- 7.9.2.7, Retrieving transceiver attributes- 7.9.2.8, Deleting a transceiver- 7.9.3.1, Provisioning cross-connects on a Wavelength Conversioncircuit pack- 7.9.3.3, Deleting a cross-connect on a Wavelength Conversion

    circuit pack- 7.9.4.2, Provisioning rules- 7.9.4.3, Example scenarios- 8.1.1, PM parameter history- 8.1.2, PM parameters- 8.1.3, Bin validity qualifiers- 8.1.4, Threshold crossing alerts- 8.2.1, PM retrieval command- 8.2.2.1, Example one- 9.5.1, Database backup- 9.6, Restarting a circuit pack- 9.7, Performing a loopback test through an SFP, XFP or MSAtransceiver on a Wavelength Conversion circuit pack- 9.7.1, How to tell when an SFP, XFP or MSA transceiver port on aWavelength Conversion circuit pack is in loopback

    - 10.1.1.2, Netstender 2060 Cooling Unit circuit pack- 10.3, Wavelength conversion circuit packs- 10.3.1, SFP transceivers

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    21/533

    Product Release 6.2STANDARDxxi

    Preface

    5.2 June 2007 Added a note to section 7.1.1.1, Controlling auto provisioning.Added a note to section 7.4.1.1, Editing the network element, site,and time zone regarding the new North American daylight savingtime rules activation.

    Added a note about OSC IP interfaces to 7.6.7, Deletingequipment.

    Added new performance metrics for the GE, STM-16, OC-3, andOC-12 optical transceivers.

    Updated the command syntax of the ENT-XCVR command insection 7.9.2.2, Provisioning transceiver ports.

    Updated the parameters PROTOCOL, LASERSTATUS, OPTLT,OPTHT, OPRLT, and OPRHT in Table 7-16, Transceiver portparameters.

    Added a note to the parameter FPSD in Table 7-16, Transceiverport parameters and in Table 7-19, Transceiver parameters.

    Removed the footnote at Table 7-16, Transceiver port parametersand at Table 7-19, Transceiver parameters.

    Updated the parameters PROTOCOL, LASERSTATUS, OPTLT,OPTHT, OPRLT, and OPRHT in Table 7-19, Transceiverparameters.

    Modified the rules for FPSD settings and laser status in7.9.2.3, Implementing advanced provisioning features.

    Modified the note about the PHYPMMON parameter in 7.9.2.3,Implementing advanced provisioning features.

    Updated the note in 7.9.2.4, Modifying the definable parameters ofa transceiver port.

    Updated Release 5.2 in Table 8-1, PM parameter history.

    Added the following parameters to Table 8-2, PM parameters:- CV- RS-BBE- RS-EB- RS-ES- RS-OFS- RS-SES- SEFS

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    22/533

    xxiiNetstender OAM&P Guide Document Version 01

    Preface

    5.2(contd)

    June 2007 Updated the following parameters in Table 8-2, PM parameters:- CVS- ES- ESS- OPR- OPT- SEFS-S- SES- SESS

    Removed the parameters FRC, FRER, and TFRC from Table 8-2,PM parameters.

    Added DWDM Bi-Directional Coupler/Splitter to 1.3.2, Opticalmultiplexing, 2.4, Equipment state management, and Table 3-1,Netstender Access Identifier Structure.

    Added 4 Channel DWDM OADM Channels 53, 55, 57, 59 to 1.3.2,Optical multiplexing and 4.5, Installing optical add-drop modulecircuit packs.

    Updated the note about cooling-unit support for the 2-port 10GWavelength Regenerator in 4.3, Installing wavelength conversioncircuit packs.

    Added the topic 4.8, Installing DWDM bi-directional coupler/splittercircuit packs.

    Updated 9.6, Restarting a circuit pack to include the 2-Port 10GWavelength Regenerator, and updated a note.

    Updated 10.1.1.2, Netstender 2060 Cooling Unit circuit pack toinclude BP1A52CA.

    Updated 10.3, Wavelength conversion circuit packs to include the2-Port 10G Wavelength Regenerator, and deleted a note.

    Added notes to step 6 in the procedure Replacing an SFP or XFPtransceiver in 10.3.1, SFP transceivers.

    Added the topic DWDM bi-directional coupler/splitter circuit packsto chapter 10.0, Replacing circuit packs.

    Removed the topic Optical Component Tray circuit packs fromchapter 10.0, Replacing circuit packs.

    Updated image of 32 Channel DWDM Mux/Demux circuit pack in10.8, Multiplex/demultiplex module circuit packs.

    Changed management LAN to craft LAN in step 3 of theprocedure in 3.2.2, Method Two: Connecting through the craft LANport.

    Removed SMF Single-Channel DCMs 40 km/60 km/80 km from thelist in 4.9, Installing dispersion compensation module circuit packs.

    Added DWDM Bi-Directional Coupler/Splitter (CS) to Table 7-2,Application circuit packs.

    Removed Power Monitor Taps 2% (PMT2) from Table 7-2,Application circuit packs.

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    23/533

    Product Release 6.2STANDARDxxiii

    Preface

    5.2(contd)

    June 2007 Added DWDM Bi-Directional Coupler/Splitter to the list in 7.12,Provisioning non-powered circuit pack ports.

    Removed SMF Single-Channel DCMs from the list in 7.12,Provisioning non-powered circuit pack ports.

    Removed PMT2 from the entry for Power Monitor Taps in 7.12,Provisioning non-powered circuit pack ports.

    Added the AID CS-(1,11,21,31)-(1-6)-(1-2) to step 1 of the procedurein 7.12.1, Modifying the parameters of a port.

    Removed the AID PMT2-(1,11,21,31)-(1-6)-(1-4) from step 1of theprocedure in 7.12.1, Modifying the parameters of a port.

    Added the AID CS-(1,11,21,31)-(1-6)-(1-2) to step 1 of the procedurein 7.12.2, Retrieving the parameters of a port.

    Removed the AID PMT2-(1,11,21,31)-(1-6)-(1-4) from step 1 of theprocedure in 7.12.2, Retrieving the parameters of a port.

    Added a note about the 10G Wavelength Regenerator to 9.7.1.1,RTRV-XCVR command.

    Changed the number of types of 4 Channel DWDM OADM from 8 to9 in 10.9, Optical add-drop module circuit packs.

    Added the following to the list in 10.2.1, OSC Coupler/Splitters:

    - OSC Double Coupler/Splitter 1510 nm- OSC Double Coupler/Splitter 1510 nm/1610 nm- OSC Double Coupler/Splitter 1610 nm- OSC Single Coupler/Splitter 1510 nm- OSC Single Coupler/Splitter 1610 nm

    Updated the authorization-level requirements for the commandsRTRV-ALM-SECU and RTRV-COND-SECU in Table 9-2, Securitycommands and authorization level required.

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    24/533

    xxivNetstender OAM&P Guide Document Version 01

    Preface

    6.1 September2007

    Added the following to 1.3.2, Optical multiplexing and 2.4,Equipment state management:- 2-Port GE Muxponder - SONET- 2-Port GE Muxponder - SDH- 4-Channel CWDM Mux/Demux- 2-Channel CWDM OADM- Double 1-Channel OADM- 1-Channel CWDM OADM- Double DWDM Red/Blue Coupler/Splitter- Single 50/50 3dB Coupler Splitter- 32-Channel DWDM Active Mux/Demux Modules 2 to 4

    Removed the following from 1.3.2, Optical multiplexing, 2.4,Equipment state management, and Table 7-2, Application circuitpacks:- 8-Channel CWDM Mux/Demux (C8MD1, C8MD2)

    - 1-Channel CWDM OADM (C1ADM)Added information about the 10G Wavelength Regenerator to 1.3.5,Wavelength conversion.

    Added 2-Port GE Muxponder - SONET and 2-Port GE Muxponder -SDH to 2.7, State management behavior interactions.

    Added the following to Table 3-1, Netstender Access IdentifierStructure:- 2-Port GE Muxponder- 4-Channel CWDM Mux/Demux- 2-Channel CWDM OADM- Double 1-Channel OADM- 1-Channel CWDM OADM- Double DWDM Red/Blue Coupler Splitter- Single 50/50 3dB Coupler Splitter

    - 32-Channel DWDM Active Mux/Demux Modules 2 to 4Removed AIDs for C8MD1, C8MD2, and PMT2 from Table 3-1,Netstender Access Identifier Structure.

    Updated the note about installation requirements for the cooling unitand the 10G Wavelength Regenerator in 4.3, Installing wavelengthconversion circuit packs.

    Added the section 4.4, Installing Muxponder circuit packs.

    Added 2-Channel N+1 CWDM OADM and Double 1-Channel OADMto 4.5, Installing optical add-drop module circuit packs.

    Added the following to 4.7, Installing multiplexer/demultiplexercircuit packs:- 4-Channel CWDM Mux/Demux- Double DWDM Red/Blue Coupler Splitter- Single 50/50 3dB Coupler Splitter

    - 32-Channel DWDM Active Mux/Demux Modules 2 to 4Removed 8-Channel CWDM Mux/Demux (C8MD1, C8MD2) from4.7, Installing multiplexer/demultiplexer circuit packs.

    Updated a note about the width of the 8-Channel CWDM Mux/Demux and the 32-Channel DWDM Mux/Demux in 4.7, Installingmultiplexer/demultiplexer circuit packs.

    Added Wavelength Manager to the heading For SDH customersonly in 7.1.1.1, Controlling auto provisioning.

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    25/533

    Product Release 6.2STANDARDxxv

    Preface

    6.1(contd)

    Added the topics 7.1.1.8, Muxponder circuit packs and 7.1.1.9,Muxponder circuit pack ports to 7.1.1, Auto provisioning.

    Updated Table 7-15, Manufacturers SFP and XFP transceiverparameters as follows:- Updated the range of values for the CONNTYPE parameter.- Corrected the XFP AID in the range of values for the AIDparameter.

    Added the following to Table 7-2, Application circuit packs:- 4-Channel CWDM Mux/Demux- 2-Channel CWDM OADM- Double 1-Channel OADM- 1-Channel CWDM OADM- Double DWDM Red/Blue Coupler Splitter- Single 50/50 3dB Coupler Splitter- Muxponder Modules- 32 Channel DWDM Active Mux/Demux Modules 2 to 4

    Updated Table 7-16, Transceiver port parameters as follows:- Added 10GELANFEC, OC192FEC, and STM64FEC to the range ofthe PROTOCOL parameter.- Updated a note about the range of protocols the 10G WavelengthRegenerator supports for the PROTOCOL parameter.- Added a cross-reference to Table 7-17, Protocols supported on10G Wavelength Regenerator ports to the description of thePROTOCOL parameter.- Added ODU2-AIS to the range of the LASERSTATUS parameter,and a note about the protocols this value applies to.-Removed the parameter CMDMDE.

    Updated 7.9.2.2, Provisioning transceiver ports as follows:- Changed heading SFP parameters to Transceiver parameters

    - Added Table 7-17, Protocols supported on 10G WavelengthRegenerator ports.- Removed the parameter CMDMDE from the command syntax forENT-XCVR.

    Added a rule for FPSD and the protocols 10GELANFEC,OC192FEC, and STM64FEC to FPSD and laser status in7.9.2.3, Implementing advanced provisioning features.

    Added 10GELANFEC, OC192FEC, and STM64FEC to the protocolparameter in 7.9.2.4, Modifying the definable parameters of atransceiver port.

    Updated Table 7-19, Transceiver parameters as follows:- Added 10GELANFEC, OC192FEC, and STM64FEC to the range ofthe PROTOCOL parameter.- Updated a note about the range of protocols the 10G WavelengthRegenerator supports for the PROTOCOL parameter.

    - Added a cross-reference to Table 7-17, Protocols supported on10G Wavelength Regenerator ports to the description of thePROTOCOL parameter.- Added ODU2-AIS to the range of the LASERSTATUS parameter,and a note about the protocols this value applies to.

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    26/533

    xxviNetstender OAM&P Guide Document Version 01

    Preface

    6.1(contd)

    Added 10GELANFEC, OC192FEC, and STM64FEC to the range ofthe PROTOCOL parameter in 7.9.2.4, Modifying the definableparameters of a transceiver port.

    Added section 7.10, 2-Port GE Muxponder provisioning.

    Added the following to 7.12, Provisioning non-powered circuit packports:- 4-Channel CWDM Mux/Demux- 2-Channel CWDM OADM- Double 1-Channel OADM- 1-Channel CWDM OADM- Double DWDM Red/Blue Coupler Splitter- Single 50/50 3dB Coupler Splitter

    Removed the following from 7.12, Provisioning non-powered circuitpack ports:

    - CWDM Mux/Demux (C8MD1, C8MD2)- CWDM OADM (C1ADM)

    Updated the range of values for the AID parameter in 7.12.1,Modifying the parameters of a port and in 7.12.2, Retrieving theparameters of a port.

    Updated the range of values for the WAVELENGTH parameter in7.12.2, Retrieving the parameters of a port.

    Updated Table 8-1, PM parameter history.

    Updated Table 8-2, PM parameters as follows:- Updated the following parameters: CVS, ES, ESS, SEFS, SEFS-S,SES, and SES-S.- Added the following parameters: CV-P, ES-P, FC-P, FCSE-RX,FRDR, HP-BBE, HP-EB, HP-ES, HP-UAS, HP-SES, NUMBITSCR,NUMBYTESCR, SES-P, TFRC-RX, TRFC-TX, UAS-P, and

    UNCRCDWRD.Updated Table 8-10, Threshold crossing alerts and their associatedprotocols as follows:- Added the protocols 10GELANFEC, OC192FEC, and STM64FEC.- Added FCSE-RX and FRDR to the GE protocol.- Updated the range of values for the protocol STM-64.

    Removed a note about the parameter SES-S and threshold crossingalerts from 8.1.4, Threshold crossing alerts.

    Added Muxponder-related commands to 8.2.1.1, Other PM retrievalcommands.

    Removed a note referring to warm and cold restarts of the WR10Gcircuit pack from 9.6, Restarting a circuit pack.

    Added all Muxponder-related commands to Table 9-2, Securitycommands and authorization level required.

    Removed a note about cold and warm restarts of the 10GWavelength Regenerator from 9.6, Restarting a circuit pack.

    Added section 9.8, Performing a loopback test through a port on aMuxponder circuit pack.

    Updated the procedure for replacing an XFP transceiver in10.3.2, 10G Wavelength Regenerator XFP transceivers.

    Added section 10.4, Muxponder circuit packs.

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    27/533

    Product Release 6.2STANDARDxxvii

    Preface

    6.1(contd)

    Added two steps (2 and 9) to the procedure for replacing XFPs in10.3.2, 10G Wavelength Regenerator XFP transceivers.

    Added the following to 10.8, Multiplex/demultiplex module circuitpacks:- 4-Channel CWDM Mux/Demux- Double DWDM Red/Blue Coupler Splitter- Single 50/50 3dB Coupler Splitter

    Added 2-Channel N+1 CWDM OADM and Double 1-Channel OADMto 10.9, Optical add-drop module circuit packs.

    Added a rule for provisioning protection switching on a 2.5GWavelength Regenerator to 7.9.4.2, Provisioning rules.

    6.2 January 2008 Added information about Extended Temperature Operation toCompliance.

    Removed Optical Booster Amplifier (OBA) and Optical Pre-Amplifier

    (OPA) from 1.3.1, Optical amplification.

    Removed 8-Channel CWDM Multiplexer/Demultiplexer (C8MD),Double DWDM Red/Blue Coupler/Splitter (CS), and 50/50 3dBCoupler/Splitter (CS) from 1.3.2, Optical multiplexing.

    Removed reference to Single ASE Noise Filter from 1.3.3, Opticalsignal conditioning.

    Updated 1.3.5, Wavelength conversion as follows:- Updated the description of the 10G Wavelength Regenerator.- Modified the reference to the availability of WavelengthRegenerator modules with protection.

    Added information about support for pass-through cross-connections to 1.3.6, Muxponder modules.

    Removed the following from 2.4, Equipment state management:- DWDM Optical Booster Amplifier- DWDM Optical Pre-Amplifier- Double DWDM Red/Blue Coupler Splitter (CS)- Single 50/50 3dB Coupler Splitter- 4-Port 1G Wavelength Regenerator with Protection- 4-Port 2.5G Wavelength Regenerator with Protection- Power Monitor Tap- Dispersion Compensating Fiber Modules SMF5, SMF10, SMF15,SMF30- Single ASE Noise Filter

    Removed Optical Booster Amplifier (OBA) and Optical Pre-Amplifier(OPA) from 2.5, Amplifier entity state management.

    Removed 4-Port 1G Wavelength Regenerator with Protection and4-Port 2.5G Wavelength Regenerator with Protection from 2.6,Wavelength conversion transceiver port state management.

    Updated Table 3-1, Netstender Access Identifier Structure asfollows:- Removed AIDs for 8-Channel CWDM Mux/Demux (C8MD); Single

    ASE Noise Filter (NF); Power Monitor Tap (PMT1); DispersionCompensating Fiber Modules SMF5, SMF10, SMF15, and SMF30;Double DWDM Red/Blue Coupler/Splitter (CS); and Single 50/503dB Coupler Splitter (CS).

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    28/533

    xxviiiNetstender OAM&P Guide Document Version 01

    Preface

    6.2 Removed DWDM Optical Booster Amplifier and DWDM Optical Pre-Amplifier from 4.1, Installing optical amplifier circuit packs.

    Updated 4.3, Installing wavelength conversion circuit packs asfollows:- Added BP1A47BB to all WR10G PEC references.- Removed 4-Port 1G Wavelength Regenerator with Protection and4-Port 2.5G Wavelength Regenerator with Protection, and addedcorresponding PEC to 4-Port 1G Wavelength Regenerator and 4-Port 2.5G Wavelength Regenerator.- Removed section on cross-connections.

    Removed 8-Channel CWDM Mux/Demux, Double DWDM Red/BlueCoupler/Splitter, and 50/50 3dB Coupler/Splitter from 4.7, Installingmultiplexer/demultiplexer circuit packs.

    Removed the following topics from 4.0, Installing optional

    Netstender circuit packs:- Installing noise filter circuit packs- Installing power monitor tap circuit packs

    Removed the topic Connecting fiber between an amplifier and aPMT from 5.0, Connecting circuit packs.

    Removed the following from Table 7-2, Application circuit packs:- Optical Booster Amplifier- Optical Pre-Amplifier- Double DWDM Red/Blue Coupler/Splitter- Single 50/50 3dB Coupler/Splitter- Dispersion Compensating Fiber modules SMF5, SMF10, SMF15,and SFM30- Power Monitor Tap- Single ASE Noise Filter

    Removed the following from Table 7-4, Required optical amplifier

    circuit pack information:- DWDM Optical Pre-Amplifier (BP1A01AA)- DWDM Optical Booster Amplifier (BP1A02AA)- Single Channel Pre-Amplifier (BP1A05PA)- Single Channel Booster Amplifier (BP1A05BA)

    Removed the following PECs from 7.7.1, Provisioning an opticalamplifier and 7.7.6, Deleting an optical amplifier: BP1A01AA,BP1A02AA, BP1A05BA, and BP1A05PA.

    Removed the following PECs from Table 7-6, Operationparameters, Table 7-7, Alarm thresholds, Table 7-9, Operationparameters, and Table 7-10, Alarm thresholds: BP1A01AA,BP1A02AA, BP1A05BA, and BP1A05PA.

    Added BP1A47BB to the range of values for the TYPE parameter in7.9.1, Provisioning wavelength conversion circuit pack equipment.

    Updated Table 7-16, Transceiver port parameters and Table 7-19,Transceiver parameters as follows:- Added a note to the WAVELENGTH parameter.- Added a note to the PHYPMMON parameter.

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    29/533

    Product Release 6.2STANDARDxxix

    Preface

    6.2 contd Added Table 7-18, BTI-supported wavelengths for a tunable 10GWavelength Regenerator.

    Updated the section Transceiver parameters in Provisioningtransceiver ports.

    Updated the section Purpose in Modifying the definableparameters of a transceiver port.

    Added information about pass-through cross-connections on aMuxponder circuit pack to the following sections:- 7.10.9.1, Provisioning a cross-connection on a Muxponder circuitpack- 7.10.9.2, Retrieving cross-connection information from aMuxponder circuit pack7.10.9.3, Deleting a cross-connection on a Muxponder circuit pack

    Updated VCG index values in the following sections:

    - 7.10.6, Provisioning OC-48 line side ports- 7.10.7, Provisioning STM-16 line side ports- 7.10.8, Retrieving Virtual Concatenation Group attributes

    Removed the following from 7.12, Provisioning non-powered circuitpack ports:- 8-Channel CWDM Mux/Demux (C8MD)- Double DWDM Red/Blue Coupler/Splitter (CS)- Single 50/50 3dB Coupler/Splitter (CS)- Power Monitor Tap (PMT1)- Single ASE Noise Filter- Dispersion Compensating Fiber Modules SMF5, SMF10, SMF15,and SMF30

    Removed AIDs for the following circuit packs from 7.12.1, Modifyingthe parameters of a port and 7.12.2, Retrieving the parameters of aport:

    - 8-Channel CWDM Mux/Demux (C8MD)- Double DWDM Red/Blue Coupler/Splitter (CS)- Single 50/50 3dB Coupler/Splitter (CS)- Power Monitor Tap (PMT1)- Single ASE Noise Filter- Dispersion Compensating Fiber Modules SMF5, SMF10, andSMF15, SMF30

    Replaced table 8-2 PM parameters with the following tables:- Table 8-2, PM Montypes: optical amplifier modules- Table 8-3, PM Montypes: OSC modules- Table 8-4, PM Montypes: IP Interface on OSC modules- Table 8-5, PM Montypes: transceiver ports on WT, WM, and WRmodules- Table 8-6, PM Montypes: 2.5G Wavelength Manager modules- Table 8-7, PM Montypes: 10G Wavelength Regenerator modules

    - Table 8-8, PM Montypes: 2-Port GE Muxponder modules- Table 8-9, PM Montypes: DWDM active mux/demux modules

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    30/533

    xxxNetstender OAM&P Guide Document Version 01

    Preface

    6.2 contd Added the following PMs to Table 8-7, PM Montypes: 10GWavelength Regenerator and Tunable 10G WavelengthRegenerator modules: BCST, FRDR, FRGT, JABR, MCST,TBYC-RX, OSIZE, OVER1518, PKTS, SESS, SIZE64, SIZE65-127,SIZE128-255, SIZE256-511, SIZE512-1023, SIZE1024-1518,USIZE.

    Added a description to the HP-UAS parameter in 8.1.2.6, 2-Port GEMuxponder modules.

    Updated the TCAs for the protocols 10GELAN, 10GELANFEC,OC192FEC, STM64FEC, and OC-192 in Table 8-10, Thresholdcrossing alerts and their associated protocols.

    Added the following commands to Table 9-1, Authorization levels:DLT-NGBR, ED-NGBR, ENT-NGBR, and RTRV-NGBR.

    Added a note to step 2 in the procedure in 9.7, Performing a

    loopback test through an SFP, XFP or MSA transceiver on aWavelength Conversion circuit pack.

    Removed DWDM Optical Booster Amplifier and DWDM Optical Pre-Amplifier from 10.5, Optical amplifier circuit packs.

    Removed Dispersion Compensating Fiber Modules SMF5, SMF10,SMF15, and SMF30 from 10.6, Dispersion compensating modulecircuit packs.

    Removed Double DWDM Red/Blue Coupler/Splitter (CS) and Single50/50 3dB Coupler/Splitter from 10.8, Multiplex/demultiplex modulecircuit packs.

    Removed OSC Single Coupler/Splitter 1610nm from 10.2.1, OSCCoupler/Splitters.

    Removed the topics Power monitor tap circuit packs and Noisefilter circuit packs from 10.0, Replacing circuit packs.

    Removed Power Monitor Tap circuit packs and ASE Noise Filtercircuit packs from list of circuit packs in 7.1.3, Pre-provisioning.

    Added 1-Channel CWDM OADM (C1ADM) to the following sections:- 1.3.2, Optical multiplexing- 2.4, Equipment state management- Table 3-1, Netstender Access Identifier Structure- 4.5, Installing optical add-drop module circuit packs- Table 7-2, Application circuit packs- 7.12, Provisioning non-powered circuit pack ports- 10.5, Optical amplifier circuit packs

    Changed all occurrences of Dual GbE Muxponder to 2-Port GEMuxponder.

    Removed the topic Protection switching on 2-Port GE Muxpondercircuit packs from Chapter 2.0, Netstender state management.

    Document Revision History

    Release Date Modifications

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    31/533

    Product Release 6.2STANDARDxxxi

    Preface

    Compliance

    FDAThis equipment is classified by the FDA under IEC 60825, parts 1 and 2, as a Class1 laser product with a Class 1 hazard rating.

    FCC

    This equipment complies with Part 15 of the FCC rules. Operation is subject to thefollowing two conditions: (1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference thatmay cause undesired operation.

    Industry Canada

    This Class A digital apparatus complies with Canadian ICES-003.

    Extended Temperature Operation

    The following BTI modules have been tested and are compliant with the industrialtemperature limit requirements (-20C to +65C) specified in GR-3108 (GenericRequirements for Network Equipment in the Outside Plant (OSP):

    2060 Main Shelf Interface

    2060 Multiport System Control Processor

    Cooling unit BP1A52CA

    1G Wavelength Translator (WT1G)

    1G Wavelength Regenerator (WR1G) 2.5G Wavelength Regenerator (WR2.5G)

    2.5G Wavelength Manager (WM2.5G)

    2-Port GE Muxponder (MXP2.5G)

    1-Channel CWDM OADM (C1ADM)

    Double 1-Channel OADM (C1ADM)

    2-Channel CWDM OADM (C2ADM)

    4-Channel CWDM Multiplexer/Demultiplexer (C4DM)

    CWDM and DWDM Splitter Combiner (CDSC) DWDM Multiplexer/Demultiplexer (D32MD1-4)

    DWDM OADM (D1ADM, D2ADM, D4ADM)

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    32/533

    xxxiiNetstender OAM&P Guide Document Version 01

    Preface

    New features and upcoming product enhancements

    With Release 6.2, BTI continues to focus on being the leading Optical EdgeSystem for delivery of Gigabit services, including 10 Gbps and Gigabit Ethernet.In addition to the new Tunable 10 G Wavelength Regenerator module andenhanced software features for new and upgraded modules, this release makesavailable extended temperature operation for a large portion of the entireNetstender product family.

    New 10G Wavelength Regenerator module features

    Tunable 10G Wavelength Regenerator module

    Ethernet Layer 2 performance monitoring

    As part of BTIs Transponder portfolio, the 10G Wavelength Regenerator moduleis a full-featured transponder for 10GbE LAN PHY, OC-192, STM-64, andOTU2/G.709 traffic protocols. Supporting the latest in pluggable opticstechnology on the client side, the 10G Wavelength Regenerator is now offeredwith a tunable MSA on the line side to support operability in DWDM applications.The tunable line interface of the Tunable 10G Wavelength Regenerator moduleprovides customers with inventory and planning benefits.

    With performance monitoring capabilities that now include Ethernet Layer 2, BTIhas expanded the current and historical performance metrics that operators canretrieve from 10G Wavelength Regenerator modules to assess system performanceand network health.

    New 2-Port GE Muxponder module feature

    Pass-through cross-connection support on 2-Port GE Muxponder SONETand SDH modules

    BTIs 2-Port GE Muxponder module increases the fill on wavelengths and enablesflexible interconnect options with GFP to facilitate transparent interconnectionwith any third-party SONET/SDH devices at a 2.5G line rate, providing a versatileway to deliver Gigabit Ethernet on both new and existing networks.

    The standards-based 2-Port GE Muxponder module, which provides GbE transportand service delivery over SONET or SDH networks, now supports pass-throughcross-connections to selectively drop or pass through traffic in a ring

    configuration. The path facilities in a pass-through cross-connection provide alarmdetection in both traffic directions.

    New extended temperature operation

    Release 6.2 marks the availability of a range modules tested for Outside Plantcabinets. Compliant with the industrial temperature limit requirements (-20C to+65C) specified in GR-3108 (Generic Requirements for Network Equipment in

  • 7/23/2019 Oamp Guide 6-2 Stand 01

    33/533

    Product Release 6.2STANDARDxxxiii

    Preface

    the Outside Plant (OSP)), the following modules extend Gigabit services andmicroWDM further into the network, facilitating innovative 1U and 2U solutions

    in Outside Plant operations: 2060 Main Shelf Interface

    2060 Multiport System Control Processor

    Cooling unit BP1A52CA

    1G Wavelength Translator (WT1G)

    1G Wavelength Regenerator (WR1G)

    2.5G Wavelength Regenerator (WR2.5G)

    2.5G Wavelength Manager (WM2.5G)

    2-Port GE Muxponder (MXP2.5G)

    1-Channel CWDM OADM (C1ADM)

    Double 1-Channel OADM (C1ADM)

    2-Channel CWDM OADM (C2ADM)

    4-Channel CWDM Multiplexer/Demultiplexer (C4DM)

    CWDM and DWDM Splitter Combiner (CDSC)

    DWDM Multiplexer/Demultiplexer (D32MD1-4)

    DWDM OADM (D1ADM, D2ADM, D4ADM)

    New software features

    End-to-end system management via SNMP

    BTI Node Controller (NNC) backward compatibility

    BTI now provides broadened SNMP capabilities to include system upgrade,database backup and restore, and SONET synchronization configurationoperations, in addition to more provisioning, performance monitoring, and faultmanagement operations.

    Release 6.2 of the Node Controller software is backward compatible to supportNNC operations and upgrades for software releases 4.1, 5.1, 5.2., and 6.1