ClusterLion

Robert Graf | CEOMobil +43 664 1314403Email: [email protected]

Page 2: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

Übersicht

1. ProLion-NetApp Allianz

2. Hochverfügbarkeit

3. MetroCluster Herausforderungen

4. ClusterLion Lösung

5. ClusterLion vs. konventionelle Lösungen

6. ClusterLion Technologie

7. Vorteile für Kunden

8. Referenzen

Page 3: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

NetApp Allianz

ProLion Geschäftsführer Robert Graf: frührer NetApp Country Manager in Österreich, 7 Jahre @ NetApp

ClusterLion exklusiv für NetApp MetroCluster NetApp Alliance Partner EU Distributionspartner: Arrow ECS

Page 4: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

Hochverfügbarkeit der IT

Unternehmenskritische Applikationen müssen heute jeder Zeit verfügbar sein.

Daher ist permanente IT Verfügbarkeit “Always-ON” für viele Unternehmen eine Grundvoraussetzung und keine Option mehr.

Jeder Ausfall kostet Geld und Image. Die meisten Branchen sind heute von einer

funktionierenden IT abhängig.

Page 5: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

Downtime-Kosten

Die Werte der Branchen und Studien variieren, doch fest steht, IT Downtime verursacht beträchtlichen Schaden.

Page 6: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

Split-Brain Syndrome Wikipedia: Split Brain ist in der Informatik

ein unerwünschter Zustand eines Computerclusters, bei dem alle Zwischenverbindungen zwischen den Clusterteilen gleichzeitig unterbrochen sind.

Zur Koordination der Transaktionen im Cluster wird in der Regel ein Cluster Interconnect verwendet. Wird die Verbindung zwischen einem oder mehreren Teilen des Clusters über diesen Weg unterbrochen, kann keines noch unterscheiden ob es sich um einen partiellen Ausfall oder eine Trennung handelt. Alle diese (nun isolierten) Clusterfragmente arbeiten für sich weiter, um die Bereitstellung des Dienstes aufrechtzuerhalten.

Page 7: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

Herausforderung jedes Storage Clusters

Jeder Storage-Anbieter am Markt benötigt ein Quorum, einen Witness oder Tiebreaker um einen automatischen Switchover im Fall einer Site-Failure durchzuführen.

In der Regel werden teure Infrastrukturinvestiotionen für einen 3. Standort und hochredundante Interconnects von den primären Standorten zum Quorum-Standort benötigt.

Mit ClusterLion fallen keine zusätzlichen Infrastrukturinvestitionen an, was zu geringst möglichen Gesamtbetriebskosten für einen automatischen Switchover führt.

ClusterLion ist exklusiv für NetApp MetroCluster verfügbar.

Page 8: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

7 Mode or cDOT 2-Pack MetroCluster

Srvc (b)

cf giveback

Srvc (a)

system01 failed !takeover!

stretched HA

A/A Controller Failure Scenario1. 1st Controller fails2. Identity „moves“ to 2nd controller3. I/O passes through 2nd controller4. After repairing1st controller,

issue „cf giveback“5. Identity „moves“ back to 1st controller6. Normal operations continue

Page 9: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

7 Mode or cDOT 2-Pack MetroCluster

Srvc (a) Srvc (b)

SiteA down orsite-connection broken?cf takeover -dcf giveback

stretched HA

MC Site Failure Scenario1. Entire Site A fails2. 2nd controller checks heartbeat, disk-

connections and IP connection while still serving its data

3. Human or process on 3rd Site identifies site-failure

4. Issue „cf takeover –d“5. Identity „moves“ to second controller

Page 10: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

cDOT 4-Pack MetroCluster / lokale HA

MC Fabric

Srvc(b)Srvc(a)

NO AUTOMATIC SWITCHOVER BETWEEN DATA CENTERS

stretched HAlocal HA local HA

Page 12: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

ClusterLion – Die Lösung

Page 13: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

UPSGrid100m

2x Ethernet

2x RS232

QRemote Quorum

100m

2x Ethernet2x RS232

Monitoring:• Power Supply• Storage Controller • Partner Status • Heart-Beat

1. Reporting:• A2: Active Controller Heartbeat• A1: Lost Cluster Partner, NVRAM

etc.• B2: No Controller Heartbeat• B1: Controller Error and Power

Alarm

2. Action:• B2: Power Off• B1: Power Off• A2: Active Controller Heartbeat• A1: Force Takeover• Q: Open Helpdesk Ticket

Switchover

ClusterLion

Open TicketPartner Helpdesk

Customer Support during Giveback

Telco BTelco A

Use Case: Power Outage

UPSGrid

MC Fabric

“Switchback”

A2 A1 B2 B1

Srvc(b)Srvc(a)

Srvc(b)

SRV1

Ethernet / SAN

SRV2

Page 14: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

ClusterLion Technologie

Page 15: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

MetroCluster Switchover

TieBreaker Manual Switchover ClusterLion

Support von 7-Mode und cDOT MC Konfigurationen ✔ ✔ ✔

Unterbrechungsfreier Betrieb selbst bei Standort Ausfall ✔ X ✔

Für den Betrieb werden nur zwei Rechenzentren benötigt X ✔ ✔

Höchste Sicherheit gegen Split-Brain und Datenverlust X ✔ ✔

Unabhängige Sicht auf den MetroCluster Status X X ✔

Einfach zu installieren (> 3h) und einfach zu betreiben X ✔ ✔

Mögliche Lösungen für NetApp MetroCluster Switchover:

Page 16: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

ClusterLion ohne Frontblende „Hot Swap“ Batterie

ClusterLion Technologie

Page 17: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

4x Power Input 4x Power Output 2x Cooling Fans 2x 24V Output for UMTS

Gateways

Reset Button 2x Serial Consol Port 6x Ethernet Connectivity

ClusterLion Technologie

Page 18: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

Premium Support: 24x7 Telefon-Support Proaktive benachtrichtigung des Kunden Automatisches Support-Ticket beim Storage

Vendor Unterstützung während Cluster-Giveback Europäischer Service-Partner: Econocom

Osiatis

ClusterLion Premium-Support

Page 19: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

Vorteile durch ClusterLion

ClusterLion erhöht die Verfügbarkeit eines zwei-Standorte Storage Clusters!

Selbst bei einem Site Desaster (K-Fall) an einem Standort werden die Cluster Services ordnungsgemäß übergeben und alle Applikationen bleiben verfügbar.

Deutlich geringere Kosten im Vergleich zu einem traditionellen Quorum Standort (Leitungskosten, Betriebskosten, Administration)!

Ein Quorum wird von ProLion ohne zusätzliche Kosten zur Verfügung gestellt.

Durch lokales Abschalten wird eine Dateninkonsistenz aufgrund eines Split Brain Syndroms durch ClusterLion ausgeschlossen!

ClusterLion kann an jedem bestehenden NetApp MetroCluster unterbrechungsfrei nachgerüstet werden.

Page 20: ClusterLion Robert Graf | CEO Mobil +43 664 1314403 Email: rg@prolion.at

...ob man sich einen IT-Betrieb ohne

ClusterLion leisten kann.

Die Frage ist nicht, ob man sich ClusterLion

leisten kann, sondern...Vielen Dank!