certificate
no. IFA1801382
dated 2019-01-16
IFAInstitutfur Arbeltsschutz derDeutschen Gesetzllchen UnfallverslcherungPrijf- und Zertifizierungsstetle im DGUVTest
Translation in any case, the German original shall prevail.European notified bodyIdentification number: 0121
EU Type-Examination Certificate
Name and address of the Venus Safety & Health Europe BVmanufacturer: Veldm, Montgomerylaan, 203
5612 BD Eindhoven
NETHERLANDS
Product designation:
Type:
VENUS V-430-SLV FFP3 NR D EN 149:2001-)-A1;2009
Particle filtering half mask with exhalation valve
Testing based on: DIN EN 149:2009
Corresponding report:
Further details:
201826330/2120 of 2019-01-14- IFA. Sankt Augustin
For protection against non highly volatile liquid and solid particles.
Class of device: FFP3 NR D
Maximum application time or maximum particle exposure one singleshift.
This document is valid in connection with the technical file and the
instructions for use in English language, both provided with IFAendorsement 1801382 of 2019-01-08.
j'.tS
The product mentioned above Is a personal protective equipment of category III in accordancewith the regulation (EU) 2016/425. This EU type-examination certificate may only be used inconjunction with corresponding control measures according to Module C2 (Annex VII) or ModuleD (Annex VIII). The product tested complies with the essential requirements of Annex II.
The present certificate is valid until and Including: 2024-01-15
Further provisions concerning the validity, the extension of the validity and other conditions arelaid down in the Rules of Procedure for Testing and Certification.
Peter Paszkiewicz ^Dr. rer. nat. Peter Paszkiewicz
Head of testing and certification body
B. Sc. Maria Scttwan
Certification officer
PZB01 Kami03-2 18
Doutsf He Ge-=et/lirhe Ivruiia iDbllV) e. V.Spilrenverband dei RewerbliLi.en Beruf^genossenschaftenund der Unfallversirherungslragei dei offenilichen HandVereinsregi'^iei Ni VR B, Amisgeri. hi (harloItent)urg
liiMitul fut ArbeKsithul^ der DCiUV (IFAl
Pru' und ZertiR/ierungsstelle irn DGUV Test
Alie Heersirake m • S Sanki Augustin • Deuischland
TeletOlii 1()| to ItOOl )8600 • Fax: -AC (0) ?0 1tOOI tSOOl
(( DAkkSDcutsche
AkkreditierungsstelleD-ZE-17005-33-00
IFAInstitut fur Arbeltsschutz derDeutschen Gesetzlichen UnfallversicherungPrijf- und ZertifizierunsssteKe im DGUVTest
Datum/Dafe:2019-01-14 Krs/MS
Translation
In any case, the German
original shall prevail.
PRUFBERICHTTESTREPORT
Nr./Afo.; 201826330/2120
1 Auftraggeber/Customer
Venus Safety & Health Pvt. Ltd.Plot No. W 284, MIDC Rabale
400 701 Navi Mumbai
India
Priifmuster/Test specimen
Respiratory protective device
2.1 Hersteiier/
ManufacturerVenus Safety & Health Europe BVVeldm, Montgoveryiaan, 2035612 BD Eindhoven
Netherlands
2.2 Bauart, Bezelchnung/Type, designation
Particle filtering half mask with exhalation valve /VENUS V-430-SLV FFP3 NR D
Kennzeichnung/Marking
VENUS V-430-SLV FFP3 NR D EN 149:2001+A1:2009
2.3 BestimmungsgemafSeVen/vendung/Intended use
For protection against non highly volatile liquid and solid particles.
Class of device: FFP3 NR D
Maximum application time or maximum particle exposure one single
shift.
2.4 Datum der Herstellung/Date of fabrication
2018
2.5 Weitere Angaben/Further details
53757 Sankt Augustin Tel.: +49 30 13001-38600 Fax: +49 30 13001-38001 email: [email protected] b-de 2016/11
PrOfbericht Nr. 201826330/2120 vom 2019-01-14 Seite2
Test Report No. as of pageIFAInstltut fiir Arbeitsschutz der
Deutschen Gesetzlichen UnfallverslcherungPriif- und Zertifizierungsstelle im DGUVTest
3.1
3.2
3.3
Prufung/Testing
Art der Prufung/Type of test
Datum der Prufung/Date of testing
EL) Type-Test
January 2019
Prufverfahren, -grundlagen/ diN EN 149:2009Test method, requirements
Beurteilung, Eignung/ The particle filtering half mask VENUS V-430-SLV FFP3 NR D ful-Assessment, suitablilty fjug the requirements of DIN EN 149:2009 for particle filtering half(Besondere Hinweise/ ^331,3 ,he device class FFP3 NR D.Special remarks)
Special Remarks:
According to a manufacturer's statement the particle filtering half mask VENUS V-430-SLV FFP3 NR D is identical in design and material, apart from the color of the exhalation valveand the marking, with the particle filtering half masks VENUS V-430-SLV FFP3 NR and VENUSV-430-SLV FFP3 NR D (Test reports 201021240/2120 of 2010-05-17 and 201421739/2120 of2014-09-15).
In the test-protocol are listed test-results from the test reports 201021240/2120 and201421739/2120 under the items 6-22.
Item 24 of the enclosed test protocol has to be regarded.
Gultlgkelt des Prufberichtes/Validity of Test Report
Die ermittelten Ergebnisse gelten nur fur die gepruften Objekte.The test results apply to the tested objects only.
Einschrankungen der Gultigkeit oder Verwendung dieses Prufberichtes:Limitation of validity or use of this Test Report:
Allgemelne Hinweise/General remarks
Dieser Prufbericht besteht ausThe present Test Report consists of
12 Seiten.Pages.
Die Seiten 1 bis 3 enthalten das Gesamtergebnis der Prufung. Zum vollstandigen Prufberichtgehort das Prufprotokoll, aus dem die Einzelangaben ersichtlich sind.Pages 1 to 3 indicate the overall test result The complete Test Report also includes the test protocolcontaining all pertinent details.
Dieser Prufbericht berechtigt n i c h t zur Verwendung des GS-Zeichens,BG-Zelchens oder CE-Zelchens.The present Test Report does not warrant the use of the GS-label, BG-label or CE-mark.
53757 Sankt Augustin Tel.:+49 30 13001-38600 Fax:+49 30 13001-38001 email: [email protected] b-de 2016/11
Prufbericht Nr. 201826330/2120 vom 2019-01-14 Seite3
Test Report No. as of pageIFAInstitut fUr Arbeitsschutz der
Deutschen Gesetzlichen UnfallversicherungPrijf- und Zertifizierungsstelle im DGUVTest
Im Ubrigen gilt die Priif- und Zertifizierungsordnung der Pruf- und Zertifizierungssteiien imDGUV Test in Verbindung mit den Allgemeinen Geschaftsbedingungen der Deutschen Gesetzlichen Unfallversicherung e.V.In all other respects the Rules of Procedure for Testing and Certification carried out by the Test andCertification Bodies in DGUV Test shall apply in conjunction with the General Business Conditions ofthe Deutsche Gesetzliche Unfallversicherung e. V.
Fur die PrCifung:For the testing:
Dipl.-lng. Judith Krisinger
Leiter(in) des PruflaborsHead of Testlaboratory
53757 Sankt Augustin Tel.:+49 30 13001-38600 Fax:+49 30 13001-38001 email: [email protected] b-de 2016/11
Prijfbericht Nr. 201826330/2120 vom2019-01-14 Seite4
Test Report No. as of pageIFAInstitut fur Arbeitsschutz derDeutschen Gesetzllchen UnfallversicherungPrlif- und Zertifizierungsstelle im DGUVTest
PrufprotokollTest protocol
1. Test Method: DIN EN 149:2009
2. Type of test: EU Type-Test
3. Customer: Venus Safety & Health Pvt. Ltd.
4. Test specimen
4.1 Type: Particle filtering half mask with exhalation valve
4.2 Designation: VENUS V-430-SLV FFP3 NR D
4.3 Marking: VENUS V-430-SLV FFP3 NR D EN 149:2001+A1:2009
4.4 Class of device: FFP3 NR D
5. Visual Inspection
The particle filtering half masks VENUS V-430-SLV FFP3 NR D, which are submitted for EU-
type-test, are, except marking and color of the exhalation valve, visually identical with the under
EC-Type test certificate No. IFA 1401068 as of 2014-09-18 tested particle filtering half masks
VENUS V-430-SLV FFP3 NR D.
6. Conditioning
6.1 Simulated wearing
The in table 4 of DIN EN 149:2009 given number of particle filtering half masks has been
subjected to simulated wearing treatment according to DIN EN 149:2009 clause 8.3.1 before
carrying out the further in table 4 given tests.
After simulated wearing treatment none of the conditioned particle filtering half masks shall
have suffered mechanical failure of the facepiece and the particle filtering half masks shall not
collapse.
The requirements are fulfilled.
6.2 Temperature conditioning
The in table 4 of DIN EN 149:2009 given number of particle filtering half masks has beensubjected to temperature conditioning according to DIN EN 149:2009 clause 8.3.2 before car
rying out the further in table 4 given tests.
After temperature conditioning none of the conditioned particle filtering half masks shall col
lapse.
The requirement is fulfilled.
Dieses Prufprotokoll darf nur vollstandig und zusammen mit den Seiten 1 bis 3 des Prufberichtes verbffentilcht werden.This Test Protocol must only be published in full wording and in connection with pages 1 to 3 of the Test Report.
Die ermittelten Ergebnisse gelten nur fur die gepruften Objekte.The test results apply to the tested object only.
53757 Sankt Augustin Tel.: +49 30 13001-38600 Fax: +49 30 13001-38001 email: [email protected] b-de 2016/11
Prufbericht Nr. 201826330/2120 vom 2019-01-14 Seite 5
Test Report No. as of pageIFAInstitut fur Arbeltsschutz der
Deutschen Gesetzllchen UnfallverslcherungPriif- und Zertifizierun.^sstelle im DGUVTest
6.3 Mechanical strength
The In table 4 of DIN EN 149:2009 given number of particle filtering half masks has been
subjected to mechanical strength conditioning according to DIN EN 149:2009 clause 8.3.3 be
fore carrying out the further in table 4 given tests.
6.4 Flow conditioning
The in table 4 of DIN EN 149:2009 given number of particle filtering half masks has been
subjected to flow conditioning according to DIN EN 149:2009 clause 8.3.4 before carrying out
the further in table 4 given tests.
7. Clogging
7.1 Test flow rate: 15 cycles/min and 2,0 I/stroke
7.2 Test conditions
According to DIN EN 149:2001 clause 8.10 clogging is performed at a Dolomite dust concen
tration of (400 ± 100) mg/m^ until the product of dust concentration and test period is 833
mg h/m^ has been clogged.
7.3 Requirements
The breathing resistance after clogging of particle filtering half masks of the device class FFP3
NR D including an exhalation valve shall not exceed 700 Pa in case of inhalation measured at
a continue flow rate of 95 l/min and 300 Pa in case of exhalation measured at a continue flow
rate of 160 l/min.
7.4 Test results
Test ConditioningInhalation resistance at
95 l/min [Pa]Exhalation resistance at
95 l/min [Pa]
1 as received 259 93
2 EN 149:2001. 8.3.2 267 96
8.
8.1
The test results refer to a dust concentration and test period product value of 833 mg h/m®.
The requirements are fulfilled.
Breathing resistance
Requirements
Max. inhalation resistance at a flow rate of 30 l/min:
Max. inhalation resistance at a flow rate of 95 l/min:
Max. exhalation resistance at a flow rate of 160 l/min:
100 Pa
300 Pa
300 Pa
Dieses Prufprotokoll darf nur vollstandig und zusammen mit den Seiten 1 bis 3 des Prufberichtes verdffentlicht werden.This Test Protocol must only be published in full wording and in connection with pages 1 to 3 of the Test Report.
Die ermlttelten Ergebnisse gelten nur fiir die gepruften Objekte.The test results apply to the tested object only.
53757 Sankt Augustin Tel.: +49 30 13001-38600 Fax: +49 30 13001-38001 email: [email protected] b-de 2016/11
Prufbericht Nr. 201826330/2120 vom 2019-01-14 SeiteG
Test Report No. as of pageIFAInstitut fur Arbeltsschutz derDeutschen Gesetzllchen UnfallversicherungPruf- und Zertifizierungsstelle im DGUVTest
8.2
8.3
9.
9.1
9.2
9.3
Test specimen
T.-No 1-2, 4-9:
T.-No 10:
T.-No 3. 11:
Test results
VENUS V-430 SLV FFP3
VENUS V-430-SLV FFP3 NR
VENUS V-430-SLV FFP3 NR D
Test Conditioning
Breathing resistance fPa]
Inhalation at
30 l/min
Inhalation at
95 l/min
Exhalation at
160 l/min
1 as received 65 259 250
2 as received 52 206 231
3 as received 67 231 104
4 EN 149:2001,8.3.1 63 245 241
5 EN 149:2001, 8.3.1 62 237 248
6 EN 149:2001, 8.3.1 60 227 245
7 EN 149:2001, 8.3.2 60 226 231
8 EN 149:2001, 8.3.2 63 242 240
9 EN 149:2001, 8.3.2 60 225 239
10 EN 149:2001, 8.3.2 & 8.3.4 71 245 127
11 EN 149:2001, 8.3.2 63 223 99
The requirements are fulfilled.
Filter penetration at test against paraffin oil
Test flow rate: 95 l/min
Requirements
Maximum filter penetration: 1,0 %
Test specimen
T.-No 1-12: VENUS V-430 SLV FFP3
T.-No 13: VENUS V-430-SLV FFP3 NR
T.-No 14-15: VENUS V-430-SLV FFP3 NR D
Dieses Prufprotokoll darf nur vollstandig und zusammen mil den Seiten 1 bis 3 des Prufberichtes verdffentilcht werden.This Test Protocol must only be published in full wording and in connection with pages 1 to 3 of the Test Report.
Die ermitteiten Ergebnisse gelten nur fur die geprCiften Objekte.The test results apply to the tested object only.
53757 Sankt Augustin Tel.: +49 30 13001-38600 Fax: +49 30 13001-38001 email: [email protected] b-de 2016/11
Prufbericht Nr. 201826330/2120 vom 2019-01-14 Seite 7
Test Report No. as of pageIFAInstitut ftir Arbeltsschutz derDeutschen Gesetzllchen UnfallversicherungPruf- und Zertifizierun.^sstelle im DGUVTest
9.4 Test results
Test ConditioningPenetration [%]
measured value 1 measured value 2
1 as received 0,10
2 as received 0,07
3 as received 0,12
4 EN 149:2001,8.3.1 0,06
5 EN 149:2001, 8.3.1 0,08
6 EN 149:2001, 8.3.1 0,10)
7 EN 149:2001, 8.3.2 0,47 0,70
8 EN 149:2001, 8.3.2 0,45 0,63
9 EN 149:2001, 8.3.2 0,58 0,71
10 EN 149:2001, 8.3.3 0,24
11 EN 149:2001, 8.3.3 0,08i
12 EN 149:2001, 8.3.3 0,11 "j"
13 EN 149:2001, 8.3.3 & 8.3.2 0,39 0,59
14 EN 149:2001, 8.10 0,811
15 EN 149:2001, 8.3.2 & 8.10 0,57
Measured value 1: Filter penetration after 3 minutes
Measured value 2: Maximum filter penetration during paraffin oil exposure until 120 mg
The requirements are fulfilled.
10. Filter penetration at test against sodium chloride
10.1 Test flow rate: 95 l/min
10.2 Requirements
Maximum filter penetration: 1,0 %
10.3 Test specimen
T.-No 1-12: VENUS V-430 SLV FFP3
T.-No 13: VENUS V-430-SLV FFP3 NR
T.-No 14-15: VENUS V-430-SLV FFP3 NR D
Dieses Prufprotokoll darf nur vollstandig und zusammen mit den Seiten 1 bis 3 des Prufberichtes verbffentlicht werden.This Test Protocol must only be published in full wording and in connection with pages 1 to 3 of the Test Report.
Die ermittelten Ergebnisse gelten nur fur die gepriiften Objekte.The test results apply to the tested object only.
53757 Sankt Augustin Tel.: +49 30 13001-38600 Fax: +49 30 13001-38001 email: [email protected] b-de 2016/11
Prufbericht Nr. 201826330/2120 vom 2019-01-14 SeiteS
Test Report No. as of pageIFAInstltut fiir Arbeitsschutz der
Deutschen Gesetzlichen UnfallverslcherungPriif- und Zertifizierun^sstelle im DGUVTest
10.4 Test results
Test ConditioningPenetration [%]
measured value 1 measured value 2
1 as received 0,13
2 as received 0,07
3 as received 0,18
4 EN 149:2001, 8.3.1 0,06 "i"
5 EN 149:2001, 8.3.1 0,05
6 EN 149:2001, 8.3.1 0,06 "j"
7 EN 149:2001, 8.3.2 0,20 0,20
8 EN 149:2001,8.3.2 0,22 0,22
9 EN 149:2001, 8.3.2 0,21 0,21
10 EN 149:2001, 8.3.3 0,06 i
11 EN 149:2001, 8.3.3 0,07
12 EN 149:2001,8.3.3 0,17
13 EN 149:2001, 8.3.3 & 8.3.2 0,23 0,23
14 EN 149:2001, 8.10 0,11
15 EN 149:2001, 8.3.2 & 8.10 0,10
Measured value 1: Penetration after 3 minutes
Measured value 2: Maximum penetration
The requirements are fulfilled.
11. Total inward leakage
11.1 Test conditions
Treadmill speed: 6 km/h
Duration of exercise: 2 min per exercise
Type of exercises: Ex. No. 1 = Walking
Ex. No. 2 = Walking and turning the head
Ex. No. 3 = Walking and head up and down
Ex. No. 4 = Walking and speaking
Ex. No. 5 = Walking
Dieses Prufprotokoll darf nur volistandig und zusammen mit den Seiten 1 bis 3 des Prufberichtes verdffentlicht warden.This Test Protocol must only be published in full wording and in connection with pages 1 to 3 of the Test Report.
Die ermittelten Ergebnisse gelten nur fur die gepruften Objekte.The test results apply to the tested object only.
53757 Sankt Augustin Tel.:+49 30 13001-38600 Fax:+49 30 13001-38001 email: [email protected] b-de 2016/11
PrCifbericht Nr. 201826330/2120 vom 2019-01-14 Seite9
Test Report No. as of pageIFAInstltut fur Arbeltsschutz derDeutschen Gesetztlchen UnfallversicherungPriif- und Zertifizierungsstelle im DGUVTest
11.2 Requirements
The total inward leakage shall not exceed 5 % in 46 of the 50 individual results (10 persons x
5 exercises).
The total inward leakage shall not exceed 2 % in 8 of the 10 arithmetic means (10 persons).
11.3 Test specimen
P.-No 1-10: VENUS V-430-SLV FFP3 NR
11.4 Test results (total inward leakage in %)
Subject ConditioningExercises
mean
1 2 3 4 5
1 as received 0.3 0,6 0.8 0.8 0.4 0,6
2 as received 0.1 0.2 0,2 0,1 0.1 0.1
3 as received 0.5 0.5 0,7 0,9 0.4 0.6
4 as received 1,4 2.3 1.5 1,5 0.8 1,5
5 as received 1.2 1,2 0.9 0,5 0.4 0.8
6 EN 149:2001, 8.3.2 0.7 0.8 0.6 0,4 0.5 0.6
7 EN 149:2001, 8.3.2 0,2 0.1 0.2 0.4 0.2 0.2
8 EN 149:2001, 8.3.2 0.6 0.6 0.6 0,5 0.4 0.5
9 EN 149:2001. 8.3.2 0.6 1,0 0,5 0,2 0,2 0.5
10 EN 149:2001. 8.3.2 3.7 3,8 2.5 0,8 2.6 2.7
12.
The requirements are fulfilled.
Practical performance
After the practical performance test the respiratory protective device was assessed by two test
subjects.
12.1 Assessment wearer 1
Head harness comfort
Security of fastenings:
Field of vision:
Additional remarks:
no complaint
no complaint
no complaint
none
Dieses Prufprotokol! darf nur vollstandig und zusammen mit den Seiten 1 bis 3 des Prufberichtes verbffentlicht werden.This Test Protocol must only be published in full wording and in connection with pages 1 to 3 of the Test Report.
Die ermittelten Ergebnisse gelten nur fur die gepruften Objekte.The test results apply to the tested object only.
53757 Sankt Augustin Tel.:+49 30 13001-38600 Fax:+49 30 13001-38001 email: [email protected] b-de 2016/11
Prufbericht Nr. 201826330/2120 vom 2019-01-14 Seite 10
Test Report No. as of pageIFAInstltut fiir Arbeitsschutz der
Deutschen Gesetzlichen UnfallversicherungPrlif- und Zertifizierungsstelle im DGUVTest
12.2 Assessment wearer 2
Head harness comfort: no complaint
Security of fastenings: no complaint
Field of vision: no complaint
Additional remarks: none
13. Carbon dioxide content of the inhalation air
13.1 Test procedure
The carbon dioxide content of the inhalation air (dead space) shall be measured at the mouth
of the dummy head with a breathing machine adjusted to 25 cycles/min and 2.0 I/stroke.
13.2 Requirement
The carbon dioxide content of the inhalation air (dead space) shall not exceed an average of
1.0 % (by volume), measured at an ahead wind-speed of 0.5 m/s.
13.3 Test results
14.
15.
16.
Concentration [Vol.-%] Test 1 Test 2 Test 3
CO2 content of the inhalation air 0,63 0,60 0,55
The requirement is fulfilled.
Package
Particle filtering half masks shall be offered for sale and packaged in such a way that they are
protected against mechanical damage and contamination before use.
The requirements are fulfilled.
Flammabllity
Four particle filtering half masks were tested, two in the state as received and two after tem
perature conditioning (DIN EN 149:2009, clause 8.3.2).
The four tested samples shall not burn with their own flame.
The requirement is fulfilled.
Dimensional stability
During the simulated wearing treatment and the temperature conditioning in accordance withclauses 8.3.1 and 8.3.2 of DIN EN 149:2009, the particle filtering half masks shall not collapse.
The requirements are fulfilled.
Dieses Prufprotokoil darf nur vollstandig und zusammen mit den Seiten 1 bis 3 des Prufberichtes veroffentlicht werden.This Test Protocol must only be published in full wording and in connection with pages 1 to 3 of the Test Report.
Die ermittelten Ergebnisse gelten nur fur die gepruften Objekte.The test results apply to the tested object only.
53757 Sankt Augustin Tel.: +49 30 13001-38600 Fax: +49 30 13001-38001 email: [email protected] b-de 2016/11
PrUfbericht Nr. 201826330/2120 vom 2019-01-14 Seitell^g^Test Report No. as of page Institutfiir Arbeitsschutz der
Deutschen Gesetzllchen UnfallverslcherungPriif- und Zertifizierun.^sstelle im DGUVTest
17. Finish of parts
Parts of the device likely to come into contact with the wearer shall have no sharp edges orburrs.
The requirements are fulfilled.
18. Head harness
18.1 Head harness after simulated wearing
After the simulated wearing treatment (DIN EN 149:2009 clause 8.3.1) of three particle filtering
half masks, no mechanical defection of the head harness shall occur.
The requirement is fulfilled.
18.2 Adjustability and hold of the head harness
The assessment was executed during the leakage tests and practical performance tests.
The requirements are fulfilled.
19. Compatibility with skin
The materials coming into contact with the wearers' skin during the leakage tests and practical
performance tests shall not cause any irritation or any other negative health effect for wearers.
The requirements are fulfilled.
20. Field of vision
The field of vision is acceptable if determined so in practical performance tests.
The requirements are fulfilled.
21. Exhalation valve
21.1 Test at exhalation flow rate of 300 l/min
Two particle filtering half masks were tested after temperature conditioning (DIN EN 149:2009
clause 8.3.2) and one particle filtering half mask was tested as received.
The requirements are fulfilled.
21.2 Test of the fitting of the exhalation valve housing
Three particle filtering half masks were tested one as received, one after temperature condi
tioning (DIN EN 149:2009 clause 8.3.2) and one after mechanical strength conditioning (DINEN 149:2009 clause 8.3.3).
The requirements are fulfilled.
Dieses Priilprotokoll darf nur voilstandig und zusammen mit den Seiten 1 bis 3 des Priifberichtes veroffentlicht werden.This Test Protocol must only be published in full wording and in connection with pages 1 to 3 of the Test Report.
Die ermittelten Ergebnisse gelten nur fur die gepruften Objekte.The test results apply to the tested object only.
53757 Sankt Augustin Tel.: +49 30 13001-38600 Fax: +49 30 13001-38001 email: [email protected] b-de 2016/11
Prufbericht Nr. 201826330/2120 vom 2019-01-14 Seite 12
Test Report No. as of pageIFAInstitut fur Arbeltsschutz derDeutschen Gesetzllchen UnfallversicherungPruf- und Zertifizierun^sstelle im DGUVTest
22. Mass of the respiratory device: 17 g
23. Marking
23.1 Marking of mask
The requirements are fulfilled.
23.2 Marking of packaging
The requirements are fulfilled.
24. Information supplied by the manufacturer
Only the instructions for use in English language were revised.
The performed test results apply to the tested objects only.
A statement about the uniformity of production cannot be derived.
Institute for Occupational Safety and Health - IFAIn charge Person responsible
liipl.-lng. Judith Krisinger Benedikt Brenner
Dieses Prufprotokoil darf nur voilstandig und zusammen mit den Selten 1 bis 3 des Prufberichtes veroffentllcht werden.This Test Protocol must only be published in full wording and in connection with pages 1 to 3 of the Test Report.
Die ermittelten Ergebnisse gelten nur fiir die gepruften Objekte.The test results apply to the tested object only.
53757 Sankt Augustin Tel.: +49 30 13001-38600 Fax: +49 30 13001-38001 email: [email protected] b-de 2016/11