Turbine ENG

Embed Size (px)

Citation preview

  • 8/18/2019 Turbine ENG

    1/4

    MITSUBISHIMechanical Drive

    Steam Turbine

    MCO_ST_2016.1_ENG _W

    © 2016 MITSUBISHI HEAVY INDUSTRIES COMPRESSOR CORPORATION All Right Reserved.

    http://www.mhicompressor.com/ 

    MCO Web site:MCO Web site:

  • 8/18/2019 Turbine ENG

    2/4

    1   2

    For PTA Plant

    (Integrally Geared Compressor Drive)

    For Mega Ethylene PlantWorld’s first Floating LNG Facility For PDH Plant

    Methanol Plant Fertilizer Plant Ethylene Plant

    Application line up

    LNG, Natural Gas Liquids (NGL), Refinery, Gas to Liquid (GTL)Upstream

    Downstream

    and other plants including Floating LNG, Industrial Power Generation and so on.

    Ethylene & Derivatives, Ammonia / Urea, Methanol, Air Separation, Propane dehydrogenation (PDH), Nitric Acid

    Blade

    Rotor 

    Thrust bearing

    Labyrinth seal

    Trip & Throttle valve

    Casing

    Diaphragm

    Governing valve

    Extraction control valve

    Journal bearing

    Mitsubishi Mechanical Drive Steam Turbine

    Mitsubishi Heavy Industries Compressor Corporation (MCO) has been buil ding steam turbines for almost

    one century. Mitsubishi mechanical drive steam turbines are being accepted favorably as smooth, economical,

    reliable turbines by all our customers.

    Today, MCO is one of the leading manufactu rers of steam tu rbin es of all types. The first mechanical drive

    turbine from our Works was delivered in 1958. Since then, we are a leading global provi der of steam turbines

    for the petrochemical industry and oil & gas field. Mitsubishi steam turbines have established a world-class

    reputation for reliability and high performance achieved through cutting edge technologies.

    Stable superior performance

    Quick and excellent After-sales service

    Easy maintenance

    High speed and Compact design

    Reliable long term operation

    Advantage of Mitsubishi Mechanical Drive Steam Turbine

    Back Pressure Turbine

    Condensing Turbine

    Automatic Extraction / Induction Turbine

    Back pressure type turbines efficiently utilize a large quantity of process steam, with the exhaust steam available

    for process heat or for the other steam–driven operations, such as low–pressure turbines.

    Condensing type turbines, which are highly economical for variable speed operations, can be directly connected to

    high speed compressors, thus providing a drive of a minimum initial cost.

    Where controlled power and process steam pressure are required, the use of the automatic extraction / induction turbine is

    highly desirable. Within capacity limits, the Mitsubishi automatic extraction turbine can supply varying amounts of extraction

    steam at constant pressure, while maintaining the required load output by governing the amount of steam admitted to the

    low-pressure part of the turbine. MCO is well experienced in induction turbine and extraction / induction turbine.

    Type and Characteristic

    Technical Evolutions of Steam Turbine

  • 8/18/2019 Turbine ENG

    3/4

  • 8/18/2019 Turbine ENG

    4/45   6

    Type of

    Mitsubishi Mechanical Drive Steam Turbine Design Features

    0

    20,000

    40,000

    60,000

    80,000

     

    100,000

    120,000

    140,000

     

    0 10,000 12,000 14,000 16,000 18,0002,000 4,000 6,000 8,000 20,000

    Application Range

       T  u  r   b   i  n  e   M

      a  x   O  u   t  p  u   t   (   k   W   )

    Turbine Max Speed (rpm)

    Model No: 9 and over 

    Model No: 8

    Model No : 5

    Model No: 4

    Model No : 3

    Model No: 7

    B: Back pressure turbine

    EB: Extraction back pressure turbine

    C: Condensing turbine

    E: Extraction condensing turbine

    DE: Double extraction turbine

    MX: Admission condensing turbine

    H: High inlet steam model

    L: Low inlet steam model

    DF: Double flow

    TF: Triple flow

    MC: Multi-casing

    BD: Both end drive

    SG: Geared turbine

    Model size

    (from 3 to 11)

    Turbine type Working steampressure and temperature

    Number of stage

    Special type

    5 E H 7 BD

    Model Code

    Back pressure turbine Extraction back pressure turbine Condensing turbine Admission condensing turbineExtraction condensing turbine Double extraction turbine

    - TTV start up

    TTV start up is MCO’s traditional design. This start up

    provides the uniform heating of turbine casing . It prevents

    the deformation of turbine casing d ue to the unequal

    heating.

    - GV start up

    MCO applies GV start up if customer request that

    procedure. MCO has a lot of experi enc e for this start

    up. GV start up pro vides the easy start up for operator.

    Start up Philosophy

    For turbine stat up, MCO has two start up procedure.

    Governing system & Safety device

    Mitsubishi Mechanical Drive Steam Turbine can

    employ any type of electronic governor that is available

    in the market. MCO can provide combined compressor

    and turbine control system as requested.

    Three safety devices can be applied.

    (i) Dual electro-hydraulic solenoid-operated valve

    (ii) Dual electronic overspeed circuit

    (iii) 2 out of 3 voting overspeed trip device

    - Governing System - Safety Device

    E/Hactuator

    Control oil

    Drain oil

    Power piston

    2 out of 3Overspeedtrip module

    (option)

    Electronic

    governor

    Operation

    panel

    DCS.

    etc.

    External signal

    Pilot valve

    Control oil supply

    Orifice

    ×2 3

    ×3

    Dual 2 way solenoid valve

    Speed sensors(Magnetic pick-ups)

    Manual trip buttonEmergency oildrain at trip

    Orifice

    Reset button

    Extraction steamnon-return valve

    Emergencytrip piston

    E/H

    actuator

    Pilot valve

    Powerpiston

    Trip & throttle valve

    Feedback lever

    Pilot valve

    Steam inlet

    Emergencytrip piston Governing

    valvesExtractioncontrol valves

    Feedbacklever