3
Nemo MD Erweiterungsmodul Grenzkontakte 2 unabhängige und isolierte Grenzkontakte Programmierung von : Messgröe Grenzwert Alarmtyp Relaisverhalten Hysterese Ansprechverzögerung Rückfallzeit Das Modul IF96005 in Verbindung mit dem Multifunktionsbaustein Nemo 96HD/HD+ ermöglicht die Überwachung zweier Messgröen durch zwei Grenzkontakte. Jeder Multifunktionsbaustein Nemo 96HD/HD+, kann maximal 2 Module IF96005 aufnehmen, in diesem Fall stehen 4 Grenzkontakte zur Verfügung. Interface Alarms 2 independent and insulated alarms Programming of: Associated quantity Intervention threshold Type of alarm State of relay Hysteresis Intervention delay Reset delay IF96005 module used with meters of Nemo 96HD/HD+ series, allows the monitoring of electrical quantities through 2 alarms. For every meter (Nemo 96DH/HD+) it is possible to connect max. 2 IF96005 modules, obtaining in this way four alarms. NT679 12- 2011 4 ème Ed. pag.1/3 MULTIFUNKTIONSBAUSTEIN MULTIMETERING ALARM ALARM ALARM Alarme 2 Alarm 2 Alarme 1 Alarm 1

M U L T IF U N K T IO N S B A U S T E IN M U LT IM E T E R ... · PDF fileM E M e s s g e e e h s d R e o, d e e n s e n M k m a e o n n g u n g z u n d e r n * N- m e E.. /!

  • Upload
    vutram

  • View
    220

  • Download
    7

Embed Size (px)

Citation preview

Page 1: M U L T IF U N K T IO N S B A U S T E IN M U LT IM E T E R ... · PDF fileM E M e s s g e e e h s d R e o, d e e n s e n M k m a e o n n g u n g z u n d e r n * N- m e E.. /!

Nemo MDErweiterungsmodulGrenzkontakte

2 unabhängige undisolierte Grenzkontakte

Programmierung von :MessgröeGrenzwert

AlarmtypRelaisverhalten

HystereseAnsprechverzögerung

Rückfallzeit

Das Modul IF96005 in Verbindung mit demMultifunktionsbaustein Nemo 96HD/HD+

ermöglicht die Überwachung zweierMessgröen durch zwei Grenzkontakte.

Jeder Multifunktionsbaustein Nemo 96HD/HD+, kann maximal 2 Module

IF96005 aufnehmen, in diesem Fall stehen 4Grenzkontakte zur Verfügung.

InterfaceAlarms2 independent andinsulated alarmsProgramming of:Associated quantityIntervention thresholdType of alarmState of relayHysteresisIntervention delayReset delay

IF96005 module used with meters of Nemo 96HD/HD+ series, allows the monitoring of electrical quantitiesthrough 2 alarms.For every meter (Nemo 96DH/HD+) it ispossible to connect max. 2 IF96005 modules,obtaining in this way four alarms.

NT6

79 1

2- 2

011

4èm

eEd

. pa

g.1/

3

MULTIFUNKTIONSBAUSTEINMULTIMETERING

ALARM ALARM ALARM

Alarme 2Alarm 2

Alarme 1Alarm 1

Page 2: M U L T IF U N K T IO N S B A U S T E IN M U LT IM E T E R ... · PDF fileM E M e s s g e e e h s d R e o, d e e n s e n M k m a e o n n g u n g z u n d e r n * N- m e E.. /!

PROGRAMMIERBARE PARAMETER (für jeden Ausgang)

Messgröe : gem. nachstehender Tabelle (abhängig von der einprogrammierten

Netzart am Nemo 96HD/HD+)

3n3E 4-Leiter Drehstromnetz, 3 Stromwandler

3-3E 3-Leiter Drehstromnetz, 3 Stromwandler

3-2E 3-Leiter Drehstromnetz, 2 Stromwandler (ARON)

1n1E Wechselstromnetz

U1-U2-U3 Phasenspannung

U12-U23-U31 verkettete Spannung

A1-A2-A3 Phasenstrom

P1-P2-P3 Wirkleistung (Phase)

P Wirkleistung (Gesamt) (einphasig bei Netzart. 1n1E)

PM Wirkleistung (Mittelwert)

VAr1-VAr2-VAr3 Blindleistung (Phase)

VAr Blindleistung (Gesamt) (einphasig bei Netzart 1n1E)

VArM Blindleistung (Mittelwert)

PF Leistungsfaktor

FrEq Frequenz

tMP1-tMP21 Temperatur1nur für IF96016 Modul

Grenzwert

Alarmtyp: Min.- und Max.-Kontakt

Relaiszustand: Relais im Normalzustand angezogen oder abgefallen

Hysterese: 0…20%

Ansprechverzögerung: 0…99s

Rückfallzeit: 0…99s

AUSGANG

2 Relais mit Wechselkontakt SPST-NO potentialfrei

Kontaktlast: 5A 250V ac cos" 1 – 3A 250V ac - cos" 0,4 – 5A 30V dc

HILFSSPANNUNG

Wert entsprechend der Kombination Multifunktionsbaustein Nemo 96HD/HD+ und

Modul IF96005

Eigenverbrauch IF96005: 1VA

PROGRAMMABLE PARAMETERS for each alarm

Associated energy: see table according to the connection programmed on the

meter

3n3E 3-phase 4-wire line, 3 systems

3-3E 3-phase 3-wire line, 3 systems

3-2E 3-phase 3-wire line, 2 Aron systems

1n1E Single-phase line

U1-U2-U3 Phase voltage

U12-U23-U31 Linked voltage

A1-A2-A3 Phase current

P1-P2-P3 Phase active power

P 3-phase active power (single-phase for 1n1E connection)

PM Active power demand

VAr1-VAr2-VAr3 Phase reactive power

VAr 3-phase reactive power (single-phase for 1n1E connection)

VArM Reactive power demand

PF Power factor

FrEq Frequency

tMP1-tMP21 Temperature1only for IF96016 module

Intervention threshold: intervention point

Type of alarm: min. and max.

State of relay: normally energised or de-energised

Hysteresis: 0…20%

Intervention delay: 0…99s

Reset delay: 0…99s

OUTPUT

2 potential-free SPST contact relaysContact range: 5A 250V ac cos 1 – 3A 250V ac - cos 0,4 – 5A 30V dc

AUXILIARY SUPPLY

Value referred to combination Nemo 96HD/HD+ multifunction meters .. + IF96005

interface

NT6

79 1

2- 2

011

4èm

eEd

. pag

.2/3

BESTELLNUMMER ORDERING CODE

IF96005 2 Grenzkontakte / 2 alarms

MEAS3n3E 3-3E 3-2E 1n1EU1 U1U2U3U12 U12 U12U23 U23 U23U31 U31 U31A1 A1 A1 A1A2 A2 A2A3 A3 A3P1P2P3

VAr1VAr2VAr3

P P P PPM PM PM PMVAr VAr VAr VAr

VArM VArM VArM VArM

Pf Pf Pf Pf

FrEq FrEq FrEq FrEqtMP1 tMP1 tMP1 tMP1tMP2 tMP2 tMP2 tMP2

Page 3: M U L T IF U N K T IO N S B A U S T E IN M U LT IM E T E R ... · PDF fileM E M e s s g e e e h s d R e o, d e e n s e n M k m a e o n n g u n g z u n d e r n * N- m e E.. /!

IME

Mes

sger

äte

beh

ält

sich

das

Rec

ht

vor,

die

tec

hn

isch

en M

erkm

ale

oh

ne

Ben

ach

rich

tig

un

g z

u ä

nd

ern

62 12

92

9692

96

81

* Module optionnel

*

ABMESSUNGEN DIMENSIONS

NT6

79 1

2- 2

011

4èm

eEd

. pag

.3/3

6 7 8 9

1 2

ANSCHLUSSBILDER WIRING DIAGRAM

S 1000/275

Eigenverbrauch Nemo 96HD/HD+ und Modul IF96005: 5VA

Eigenverbrauch Nemo 96HD/HD+ und 2 Module IF96005: 6VA

ISOLATION (EN61010)

Wert entsprechend der Kombination Multifunktionsbaustein Nemo 96HD/HD+ und

Modul IF96005

Prüfspannung 2 kV R.M.S. 50Hz/1min

Prüfkreis: Messeingang, Hilfsspannung, Ausgang 1 - Ausgang 2

GEHÄUSE

Gehäuse: Modul mit Stecker (zur Verbindung mit dem Gerät Nemo 96HD/HD+)

Gehäusetiefe: 81mm (Nemo 96HD/HD+ und Modul)

Anschluss: Schraubenanschluss

Anschluss: Draht (fest) max. 4,5mm2

Leitung (flexibel) max. 2,4mm2

Gehäusematerial: Polycarbonat selbstverlöschend

Gewicht: 40 Gramm

Rated burden IF96005: 1VA

Rated burden Nemo 96HD/HD+ and IF96005 interface: 5VA

Rated burden Nemo 96HD/HD+ and 2 IF96005 interface: 6VA

INSULATION (EN61010)

Value referred to combination Nemo 96HD/HD+multifunction meters . + IF96005

interface

A.C. voltage test 2 kV r.m.s. value 50Hz/1minConsidered circuits: measure, aux. supply, output 1 - output 2

HOUSING

Housing: modulewith connector for connection Nemo 96HD/HD+ meter

Max. depth: 81mm (Nemo 96HD/HD+ and module)

Connections: screw terminals

Terminals range: rigid cable max. 4,5mm2

flexible cable max. 2,4mm2

Housing material: self-extinguishing policarbonate

Weight: 40 grams

BESTELLNUMMERCODE

IF96005

Beschreibung Max. Anzahl

2 Grenzkontakte2 alarms 2

Steckplatz / Position

A B C D

FIRMWARE1

FIRMWARE1

AlleAll

A B C D

1FIRMWARE-Version: Die Tabelle gibt an, welche Firmware-

Version der Nemo 96HD/HD+ benötigt, um dieses

Erweiterungsmodul zu unterstützen.

Mit Hilfe des Moduls IF96001 (RS485) oder IF96002 (RS232),

kann ein Update der Firmware vorgenommen werden. Hierzu

benötigen Sie einen PC und die entsprechende Software.

1FIRMWARE VERSION : on the table it is shown the firmwareversion of the meter which is necessary to support the function of the extra module.

By using an IF96001 (RS485) or IF96002 (RS232)

communication module it is possible to update the

firmware version directly of field, with the help of a PC

and the necessary software.

Optionales Modul