2
The digital future in urology 780 760 662 1200 240 650 650 BÖHME MEDIZINTECHNIK GmbH Mammography, Digital Systems, Sonography, X-Ray Braschwitzer Straße 10, D - 06188 Peißen phone +49 (345) 56 36 98 10 fax +49 (345) 56 36 98 11 info@boehme - medizintechnik.de www.boehme - medizintechnik.de Dimensions and specifications are non-binding. Pictures and description were correct at the time of printing. Subject to modifications. © BÖHME MEDIZINTECHNIK GmbH March 2008, Composing and Layout atnex x t – Agency for Design and E-Business Spatial planning right oriantated execution - top view tabletop extension + footrest Generator Philips Optimus 50 R/F Parameter Value Protection class I EMV Group 1, class A Electricity supply 400 V ± 10 %, 50/60 Hz, triphasic Main resistance 0,3 Ω/145A Power output 50 kW High voltage generation Transformer Radiography yes Fluoroscopy yes Dose monitoring yes Continual output 500 W (6 f/min at 50 kW; 0,1 s) Image technology kV, continually falling load, automatic exposure control kV, mA, constant load, automatic exposure control kV, mAs, constant load kV, mAs, s, constant load kV, mA, s, constant load Maximum electricity input is achieved under the following conditions Tube power 50 kW Mode kV-mAs Focus Large High voltage 77 kV Current-time product 65 mAs Exposure time 0,1 s Adjustment range: X-rays without AEC automatic exposure control Tube voltage 40 kV - 150 kV, can be adju- sted in 1 kV steps Tube current 1 mA - 650 mA, for kV-mA-s and kV-mAs-modes, can be adjusted in steps of 25 %, 12 %, 6 % mAs 0,5 mAs - 850 mAs, can be adjusted in steps of 25 %, 12 %, 6 % Exposure times 1 ms - 6 s (16 s), can be adjusted in steps of 25 %, 12 %, 6 % X-rays with AEC automatic exposure control mAs 0,5 mAs - 600 mAs Switch times 1 ms - 4 s Density levels can be adjustedin Steps of 25 %, 12 %, 6 % Fluoroscopy Tube voltage 40 kV - 125 kV, via kV/mA characteristic Tube current 0,1 mA - 6 mA, via kV/mA characteristic 16"/ø 38 cm image intensifier with TV subsystem Parameter Value Type Philips Camera 1k2 CCD camera Modes three-fold mode 38/25/17 cm TV-subsystem XTV 7 eg high line resolution User interface Parameter Value Equipment control/operation console yes Remote control yes Foot switch yes Remote control on table side yes Touch panel yes Environmental conditions Parameter Value Temperature range 10 °C - 40 °C Relative air humidity 15 % - 90 % no condensation Air pressure 70 kPa - 110 kPa He urological workstation DURONOVA is one of the latest generation of remote-controlled systems from our company BÖHME MEDIZINTECHNIK GmbH. With an attractive design of the highest quality stan- dards, its simple colour and styling improve the well- being of both patients and medical personnel. Our systems are reliable, simple to operate, efficient and offer an unrivalled digital image quality. mobile equipment holder for monitors and touchpanel

The digital future in urology - DuroNova

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

The digital future in urology

780

760

662

1200

240

650

650

Böhme medizintechnik GmbH Mammography, Digital Systems, Sonography, X-Ray

Braschwitzer Straße 10, D - 06188 Peißen phone +49 (345) 56 36 98 10 fax +49 (345) 56 36 98 11

info@boehme - medizintechnik.dewww.boehme - medizintechnik.de Dimensions and specifications are non-binding. Pictures and description were correct at the time of printing. Subject to modifications. © BöHme medizintecHnik GmbH March 2008, Composing and Layout atnexxt – Agency for Design and E-Business

Spatial planningright oriantated execution - top view

tabletop extension + footrest

Generator Philips Optimus 50 R/FParameter Value

Protection class I

EMV Group 1, class A

Electricity supply 400 V ± 10 %, 50/60 Hz, triphasic

Main resistance 0,3 Ω/145 A

Power output 50 kW

High voltage generation Transformer

Radiography yes

Fluoroscopy yes

Dose monitoring yes

Continual output 500 W (6 f/min at 50 kW; 0,1 s)

Image technology kV, continually falling load, automatic exposure control

kV, mA, constant load, automatic exposure control

kV, mAs, constant load

kV, mAs, s, constant load

kV, mA, s, constant load

Maximum electricity input is achieved under the following conditions

Tube power 50 kW

Mode kV-mAs

Focus Large

High voltage 77 kV

Current-time product 65 mAs

Exposure time 0,1 s

Adjustment range: X-rays without AEC automatic exposure control

Tube voltage 40 kV - 150 kV, can be adju-sted in 1 kV steps

Tube current 1 mA - 650 mA, for kV-mA-s and kV-mAs-modes, can be adjusted in steps of 25 %, 12 %, 6 %

mAs 0,5 mAs - 850 mAs, can be adjusted in steps of 25 %, 12 %, 6 %

Exposure times 1 ms - 6 s (16 s), can be adjusted in steps of 25 %, 12 %, 6 %

X-rays with AEC automatic exposure control

mAs 0,5 mAs - 600 mAs

Switch times 1 ms - 4 s

Density levels can be adjustedin Steps of 25 %, 12 %, 6 %

Fluoroscopy

Tube voltage 40 kV - 125 kV, via kV/mA characteristic

Tube current 0,1 mA - 6 mA, via kV/mA characteristic

16"/ø 38 cm image intensifier with TV subsystem

Parameter Value

Type Philips

Camera 1k2 CCD camera

Modes three-fold mode 38/25/17 cm

TV-subsystem XTV 7 eg high line resolution

User interfaceParameter Value

Equipment control/operation console

yes

Remote control yes

Foot switch yes

Remote control on table side yes

Touch panel yes

Environmental conditionsParameter Value

Temperature range 10 °C - 40 °C

Relative air humidity 15 % - 90 % no condensation

Air pressure 70 kPa - 110 kPa

He urological workstation DURONOVA is one of the latest generation of remote-controlled systems from our company BöHme medizintecHnik GmbH.With an attractive design of the highest quality stan-dards, its simple colour and styling improve the well-being of both patients and medical personnel.Our systems are reliable, simple to operate, efficient and offer an unrivalled digital image quality.

mobile equipment holder for monitors and touchpanel

ContentThe systemUrology tableX-ray generatorX-ray tubeCollimatorImage intensifierFlat screen monitorsDICOM-Software

Accessories

Technical data

Room design

Urological workstation DURONOVA – the digital futurein urologyFuture-proof systems for diagnostics and the-rapy are essential in the digital age. It is a que-stion of combining established concepts with innovative medical technology. The urological work-station allows the urologist to conduct all routi-ne urological and gynaecological examinations. This includes:

• Urograms with injections or infusions• Retrograde pyelography• Cystography and urethrography• Micturition cystography• Percutaneous kidney stone fragmentation• Cystoscopy, endoscopy• Transurethral resection• Percutaneous nephroscopy• Serial angiography with image intensifier and DSI

Furthermore the system can be used as an operating table for invasive procedures with xray monitoring.

Completely digital system for radiography and fluoroscopy.

Advantages of digital radiography:• reduced radiation exposure for patient and medical personnel• immediate access to x-ray images• improved diagnostic possibilities using additional image processing• simple archiving and export of data via DICOM• consequent savings in time and costs

ConformityThis medical device conforms to the regulations of the EU Guidelines 93/42 EEC (93) Medical Device Directive.

High degree of flexibilityThe available profiles allow individual adjustments of the workstation to a particular type of examination and a particular patient – whether a child or an adult.

The system – tailored to your needsThe urological workstation has the following components:

• Urology table Uromat 3000• X-ray generator Optimus RF 50 kW• X-ray emitter DR 1825• Servo-controlled collimator R 503 MLP/A• Image intensifier 38 cm, 1 k CCD camera, TV subsystem• Live image monitor for fluoroscopy, monitor for last image hold (LCD)• DICOM software solution and image processing software

With these components the system can reliably support you.

optionalGenerator: Optimus 65R/F, Optimus 80R/FTubes: DU 2550, DU 33100

Urology table – Work comfortablyErgonomy has the topmost priority for comfortable, non-fatiguing operation. The heart of the urological workstation is highly sensitive but nevertheless ro-bust mechanics which allow the table to be adjusted, swivelled and tilted in any position, smoothly and con-tinuously: laterally, longitudinally, from the 88° vertical to the 20° Trendelenburg position. The microprocessor control system also allows isocentric tilting around the table end. Doctors and their assistants are thus assured of optimal operating conditions as well as allowing patients to get on the table comfortably at minimum table height.

Ergonomic operationA manual control unit or multifunction footswitch allows the table to be comfor-tably controlled. The memory function al-lows you to save three unit positions during an examination and when needed the unit can be returned to these positions fully au-tomatically. Similarly the x-ray unit support arm can be easily moved longitudinally; the x-ray emitter can easily be moved into the park position if needed. Depending on the room layout, the table is available in left- and right-hand configurations. It can also be free-standing or installed near a wall in a space-saving configuration.

X-ray generator – operator-friendly and versatileThe Optimus 50 R/F x-ray generator from Philips is sim-ple to operate with up to 1000 individual anatomical x-ray programs, guaranteeing reliable and high quality images with reduced radiation emission and increased lifetimes of the x-ray tubes.

Opional Optimus 65 R/F or 80 R/F as per client request

X-ray tube – effectiveType of x-ray emitter DR 1825

X-ray tubes DU 2550

Focus sizes 0,6 mm/1,0 mm

Maximum anode heat storage capacity

220 kJ/300 kHU

Maximum heat storage capacity

1260 kJ/1700 kHU

Inherent filtration 1,5 mm Al (75 kV)X-ray emitter 0,77 mm AlFixed additional filter 0,8 mm Al

Nominal voltage 150 kV

Collimator – accurateThe servo-controlled collimator adjusts the optionally round or rectangular radioscopy window to particu-lar requirements and ensures that only the area to be examined is irradiated. This ensures that patients and medical personnel have the least possible radiation ex-posure.

Image intensifier with TV subsystem – realistic

The image intensifier converts the x-rays into a visible, amplified image that is sent to the CCD camera with a resolution of 1 Mpixel and transmitted to the screen.

Monitor – razor-sharpEven the smallest details are visible on the high resolution 21" LCD monitor thanks to a resolution of 1280×1024 pixels and a greyscale of 12 bits. This greatly simplifies diagnosis, including early diagnosis.

The symbol buttons allow simple navigation and uncomplicated programming of the illuminated

hand control panel.

DICOM-software solution – communicative

DICOM modality work list yes

DICOM PRINT yes

DICOM STORE yes

DICOM Q/R (SCP) yes, optional

Shedule management yes, optional

DICOM CD yes

PAPER PRINT yes

DICOM MPPS yes, optional

Remote maintenance connection(updates)

yes

Export/Backup on CD/DVD yes

Accessories – individualThe urological workstation is a cost-effective and com-plete solution.Extras, such as a multifunction foot switch, foot switch for exposure/x-ray, unit-side re-mote control of the most important functions, generator operator console and touch panel operation, are already included in the basic configuration.To allow you to configure the urological workstation exactly to your needs, there is an extensive range of optional extras available.

This includes:

• DICOM interface

• Patient positioning mat

• Wedge-shaped head support cushion

• Paper roll holder

• Patient grips

• Tabletop extension

• Footrest

• Leg supports - basic

• Leg supports - Corafix

• Elbow supports

• Shoulder supports

• Rinse bowl

• Rinse bag mount

• Micturition seat

• Infusion bottle holder and infusion arm rest

• Monitor support arm

• Compression belt

Technical dataPatient table Uromat 3000

Parameter Value

Table height min. 62,5 cm (without ii),min. 75 cm (with 16" ii),max. 125 cm

Tilt range Head-up position up to 88°,Trendelenburg pos. up to 20°

Digital angle display In 1° - steps

Movement range of x-ray emitter

12 cm (with 16" ii)

Park position x-ray tube 36 cm

Focus film distanc 115 cm

Tabletop ii distance 6,5 cm

Tabletop size 120×76 cm,198×76 cm (with tabletop extension)

Table Al equivalent 1,0 mm Al

Tabletop Al equivalent 0,5 mm Al

Maximum exposure 205 kg

Longitudinal movement ± 24 cm

Lateral movement ± 13 cm

Speed of tabletopand height movement

20 mm/s ± 2 mm/s

Size when assembled 370×195 cm

Height 260 cm

Ralco CollimatorParameter Value

Shutter - rectangular light field yes

Shutter - round light field yes

Automatic collimator yes

Al equivalent 2,0 mm Al

Visor yes

Weight approx. 11 kg

X-ray tube Dunlee DR 1825 (tubes DU 2550)

Parameter Value

Focus sizes 0,6 mm/1,0 mm

Anode nominal input power 25 kW (for small foci)

Maximum anode heat storage capacity

220 kJ/300 kHU

Maximum heat storage capacity 1260 kJ/1700 kHU

Inherent filtration 1,5 mm Al (75 kV)

X-ray emitter 0,77 mm Al

Fixed additional filter 0,8 mm Al

Nominal voltage 150 kVIsocentric tilting in the range ± 20° for the most ergonomic operation