28
CFF45 Compressor Fridge/Freezer Operating manual EN PORTABLE REFRIGERATION CFF SERIES

CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

CFF45

Compressor Fridge/FreezerOperating manual

EN

PORTABLE REFRIGERATIONCFF SERIES

CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12

Page 2: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

CFF-45--O-EN-AUS.book Seite 2 Montag, 25. Juni 2018 12:42 12

Page 3: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

CFF45

3

Please read this manual carefully before starting the device. Keep it in a safe place for future reference. If the device is passed on to another person, this manual must be handed over to the user along with it.

The manufacturer cannot be held liable for damage resulting from improper usage or incorrect operation.

Contents1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42.1 General safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42.2 Operating the cooling device safely . . . . . . . . . . . . . . . . . . . . . . . . . .6

3 Scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

4 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

5 Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

6 Function description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96.1 Scope of functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96.2 Operating and display elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127.1 Before initial use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127.2 Energy saving tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147.3 Connecting the cooler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157.4 Using the battery monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167.5 Using the cooler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177.6 Setting the temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197.7 Setting the display brightness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197.8 Switching off the cooler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197.9 Defrosting the cooler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207.10 Replacing the AC fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207.11 Replacing the device DC Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207.12 Replacing the DC plug fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217.13 Replacing the light PCB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

8 Cleaning and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

10 Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

CFF-45--O-EN-AUS.book Seite 3 Montag, 25. Juni 2018 12:42 12

Page 4: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

Explanation of symbols CFF45

4

11 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

12 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

1 Explanation of symbols

D

!

!

A

I2 Safety instructions

2.1 General safety

!WARNING!

• Do not operate the cooling device if it is visibly damaged.

• If this cooling device's power cable is damaged, it must be replaced by the manufacturer, customer service or a similarly qualified person in order to prevent safety hazards.

• This cooling device may only be repaired by qualified personnel. Improper repairs can lead to considerable hazards.

DANGER! Safety instruction: Failure to observe this instruction will cause fatal or serious injury.

WARNING! Safety instruction: Failure to observe this instruction can cause fatal or serious injury.

CAUTION! Safety instruction: Failure to observe this instruction can lead to injury.

NOTICE! Failure to observe this instruction can cause material damage and impair the function of the product.

NOTE Supplementary information for operating the product.

CFF-45--O-EN-AUS.book Seite 4 Montag, 25. Juni 2018 12:42 12

Page 5: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

CFF45 Safety instructions

5

• This cooling device can be used by children aged 8 years or over, as well as by persons with diminished physical, sensory or mental capac-ities or a lack of experience and/or knowledge, providing they are supervised or have been taught how to use the cooling device safely and are aware of the resulting risks.

• Cleaning and user maintenance must not be carried out by children without supervision.

• Children must not play with the cooling device.

• Children must be supervised to ensure that they do not play with the cooling device.

• Always keep and use the cooling device out of the reach of children under the age of 8 years.

• Do not store any explosive substances such as spray cans with a flammable propellant in the cooling device.

!CAUTION!

• Disconnect the cooling device from the power supply– before each cleaning and maintenance– after every use

• Food may only be stored in its original packaging or in suitable containers.

ANOTICE!

• Check that the voltage specification on the type plate corresponds to that of the energy supply.

• Only connect the cooling device as follows:– With the DC connection cable to a DC power supply in the vehicle– Or with the AC connection cable to an AC power supply

• Never pull the plug out of the socket by the cable.

• If the cooling device is connected to a DC outlet: Disconnect the cooling device and other power consuming devices from the battery before connecting a quick charging device.

• If the cooling device is connected to a DC outlet: Disconnect the cooling device or switch it off when you turn off the engine. Otherwise you may discharge the battery.

• The cooling device is not suitable for transporting caustic materials or materials containing solvents.

CFF-45--O-EN-AUS.book Seite 5 Montag, 25. Juni 2018 12:42 12

Page 6: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

Safety instructions CFF45

6

• The insulation of the cooling device contains flammable cyclopentane and requires special disposal procedures. Deliver the cooling device at the end of its life-cycle to an appropriate recycling center.

2.2 Operating the cooling device safely

!CAUTION!

• Before starting the cooling device, ensure that the power supply line and the plug are dry.

ANOTICE!

• Do not use electrical devices inside the cooling device unless they are recommended by the manufacturer for the purpose.

• Do not place the cooling device near naked flames or other heat sources (heaters, direct sunlight, gas ovens etc.).

• Danger of overheating!Ensure at all times that there is a minimum of 50 mm ventilation on all four sides of the cooling device. Keep the ventilation area free of any objects that could restrict the air flow to the cooling components.Do not place the cooling device in closed compartments or areas with none or minimal air flow.

• Ensure that the ventilation openings are not covered.

• Do not fill the inner container with ice or fluids.

• Never immerse the cooling device in water.

• Protect the cooling device and the cable against heat and moisture.

CFF-45--O-EN-AUS.book Seite 6 Montag, 25. Juni 2018 12:42 12

Page 7: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

CFF45 Scope of delivery

7

3 Scope of delivery

Item Quantity Description

1 1 Cooler

2 1 Connection cable for DC connection

3 1 Connection cable for AC connection

4 2 Carry handle, consisting of:

• 2 holders

• 1 handle

• 4 fastening screws

– 1 Operating manual

1

1

3

2

4

1

CFF-45--O-EN-AUS.book Seite 7 Montag, 25. Juni 2018 12:42 12

Page 8: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

Accessories CFF45

8

4 AccessoriesAvailable as accessory (not included in scope of delivery):

5 Intended useThe cooler is suitable for cooling and freezing foods.

The cooler is designed to be operated from:

• a DC on-board power supply of a vehicle, boat or caravan

• a DC auxiliary battery

• an AC power supply

The cooling device is intended to be used in household and similar applications such as

• staff kitchen areas in shops, offices and other working environments

• farm houses

• clients in hotels, motels and other residential type environments

• bed and breakfast type environments

• catering and similar non-retail applications

!

Designation Ref. no.

Universal fixing kit (belt system) CFX-UFK 9108300002

Insulated protective cover CFF-IC45 9600012920

CAUTION! Health hazard!Please check if the cooling capacity of the device is suitable for storing the food or medicine you wish to cool.

CFF-45--O-EN-AUS.book Seite 8 Montag, 25. Juni 2018 12:42 12

Page 9: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

CFF45 Function description

9

6 Function descriptionThe cooler can chill products, keep them cool as well as freeze them. A low maintenance refrigerant circuit with compressor provides the cooling. The generous insulation and powerful compressor ensure efficient and fast cooling.

The cooler is portable.

The cooler can withstand a short-term inclination of 30°, for example on boats.

6.1 Scope of functions

• Power supply with priority circuit for connecting to the AC mains

• Three-level battery monitor to protect the vehicle battery

• Display with temperature gauge in °C and °Fswitches off automatically at low battery voltage

• Temperature setting: With two buttons in steps of 1 °C (2 °F)

• Display dimming function with 3 brightness levels

• Removable wire basket

• Removable carrying handles

6.2 Operating and display elements

Lid latches

2

CFF-45--O-EN-AUS.book Seite 9 Montag, 25. Juni 2018 12:42 12

Page 10: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

Function description CFF45

10

Operating panel

Item Description Explanation

1 ONOFF

Switches the cooler on or off when the button is pressed for between one and two seconds

2 POWER “P” Status indication

LED lights up green: Compressor is on

LED lights up orange: Compressor is off

LED flashes orange: display switched off automatically due to low battery voltage

3 ERROR LED flashes red: Device is switched on but not ready for operation

4 SET Selects the input mode– Temperature setting– Celsius or Fahrenheit display– Set battery monitor– Set brightness of display

5 – Display, shows the information

6 DOWN – Press once to decrease the value

7 UP + Press once to increase the value

°

1 2 3 4 5 763

CFF-45--O-EN-AUS.book Seite 10 Montag, 25. Juni 2018 12:42 12

Page 11: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

CFF45 Function description

11

Connection sockets

Item Description

1 Connection socket AC voltage supply

2 AC Fuse holder

3 Connection socket DC voltage supply

4 DC Fuse

100-240V~AC

DC 10AFuse

12-24V DC

3 41 24

CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12

Page 12: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

Operation CFF45

12

7 Operation

7.1 Before initial use

I

Mounting the handles

The handles are enclosed unassembled. If you wish to attach the handles, proceed as follows:

➤ Make a handle by putting two holders (1) and a handle (2) together.

➤ Fasten the holders with the enclosed screws in the holes provided.

NOTE Before starting your new cooler for the first time, you should clean it inside and outside with a damp cloth for hygienic reasons (please also refer to the chapter “Cleaning and maintenance” on page 22).

1

2

1

6

CFF-45--O-EN-AUS.book Seite 12 Montag, 25. Juni 2018 12:42 12

Page 13: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

CFF45 Operation

13

Opening or removing the lid

The lid can be opened from either side or removed completely without the need of tools as follows:

➤ To open the lid, unlatch in the preferred opening direction, (A) or (B).

➤ To remove the lid, unlatch both sides at the same time (C).

A

B

C

7

CFF-45--O-EN-AUS.book Seite 13 Montag, 25. Juni 2018 12:42 12

Page 14: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

Operation CFF45

14

Lid stop position

The lid has a built-in stop position (A).Do not force the lid past the built-in stop (B).

A

Selecting the temperature units

Temperature display units can be switched between Celsius and Fahrenheit as follows:

➤ Switch on the cooler.

➤ Press the “SET” button (fig. 3 4, page 10) twice.

➤ Use the “UP +” (fig. 3 7, page 10) or “DOWN –” (fig. 3 6, page 10) buttons to select Celsius or Fahrenheit.

✓ The selected temperature unit then appears in the display for a few seconds. The display flashes several times before it returns to the current temperature.

7.2 Energy saving tips

• Choose a well ventilated location which is protected from direct sunlight.

• Allow warm food to cool down first before placing it in the cooling device to keep cool.

• Do not open the cooling device more often than necessary.

• Do not leave the cooling device open for longer than necessary.

NOTICE! Danger of damage!Failure to observe this instruction can cause the lid to break off.

➤ If the lid has been forced too far, follow the steps described in the chapter “The lid has been forced past the built-in stop” on page 24.

BA8

CFF-45--O-EN-AUS.book Seite 14 Montag, 25. Juni 2018 12:42 12

Page 15: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

CFF45 Operation

15

• Defrost the cooler once a layer of ice forms.

• Avoid unnecessarily low temperatures.

7.3 Connecting the cooler

Connecting to a battery (Vehicle or boat)

The cooler can be operated with 12 V or 24 Vg.

A

For safety reasons the cooler is equipped with an electronic system to prevent polarity reversal. This protects the cooler against short-circuiting when connecting to a battery.

Using the fused DC plug

A

➤ Plug the DC connection cable (fig. 1 2, page 7) into the DC voltage socket of the cooler (fig. 4 3, page 11).

➤ Connect the connection cable to a DC power outlet.

Connecting to an AC power supply (e.g. in the home or office)

D

NOTICE! Danger of damage!Disconnect the cooler and other consumer units from the battery before you connect the battery to a quick charging device.Overvoltage can damage the electronics of the device.

NOTICE! Danger of damage!For protection of the device the DC cable supplied includes a fuse inside the plug. Do not remove the fused DC plug. Only use the DC cable supplied.

DANGER! Danger of electrocution!• Never handle plugs and switches with wet hands or if you are

standing on a wet surface.• If you are operating your cooler on board a boat from a AC power

supply, you must install a residual current circuit breaker between the AC power supply and the cooler.Seek advice from a trained technician.

CFF-45--O-EN-AUS.book Seite 15 Montag, 25. Juni 2018 12:42 12

Page 16: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

Operation CFF45

16

The coolers have an integrated multi-voltage power supply with priority circuit for connecting to an AC voltage source. The priority circuit automatically switches the cooler to AC operation if the device is connected to an AC power supply, even if the DC connection cable is still attached.

When switching between the AC power supply and the battery supply, the red LED may light up briefly.

➤ Plug the AC connection cable (fig. 1 3, page 7) into the AC voltage socket of the cooler (fig. 4 1,page 11).

➤ Connect the connection cable to an AC power outlet.

7.4 Using the battery monitor

The device is equipped with a multi-level battery monitor that protects your vehicle battery against excessive discharging when the device is connected to the on-board DC supply.

If the cooler is operated when the vehicle ignition is switched off, the cooler switches off automatically as soon as the supply voltage falls below a set level. The cooler will switch back on once the battery has been recharged to the restart voltage level.

A

In “HIGH” mode, the battery monitor responds faster than at the levels “LOW” and “MED” (see the following table).

The battery monitor mode can be selected as follows:

➤ Switch on the cooler.

➤ Press the “SET” button (fig. 3 4, page 10) three times.

NOTICE! Danger of damage!When switched off by the battery monitor, the battery will no longer be fully charged. Avoid starting repeatedly or operating current consumers without longer charging phases. Ensure that the battery is recharged.

Battery monitor mode LOW MED HIGH

Switch-off voltage at 12 V 10.1 V 11.4 V 11.8 V

Restart-voltage at 12 V 11.1 V 12.2 V 12.6 V

Switch-off voltage at 24 V 21.5 V 24.1 V 24.6 V

Restart voltage at 24 V 23.0 V 25.3 V 26.2 V

CFF-45--O-EN-AUS.book Seite 16 Montag, 25. Juni 2018 12:42 12

Page 17: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

CFF45 Operation

17

➤ Use the “UP +” (fig. 3 7, page 10) or “DOWN –” (fig. 3 6, page 10) buttons to select the battery monitor mode.

✓ Display will be as follows:Lo (LOW), ΠEd (MED), Hi (HIGH)

✓ The selected mode then appears in the display for a few seconds. The display flashes several times before it returns to the current temperature.

I

7.5 Using the cooler

A

➤ Place the cooler on a firm foundation. Make sure that the ventilation slots are not covered and that the heated air can dissipate.

I➤ Connect the cooler, see chapter “Connecting the cooler” on page 15.

A➤ Press the “ON/OFF” button (fig. 3 1, page 10) for between one and two

seconds.

✓ The LED “P” lights up (fig. 3 2, page 10).

✓ The display (fig. 3 5, page 10) switches on and shows the current temperature.

✓ The cooler starts cooling the interior.

NOTE When the cooler is supplied by the starter battery, select the battery monitor mode “HIGH”. If the cooler is connected to a supply battery, the battery monitor mode “LOW” will suffice.

NOTICE! Danger of overheating!Ensure at all times that there is sufficient ventilation so that the heat that generated during operation can dissipate. Ensure that the ventilation slots are not covered. Make sure that the device is sufficiently far away from walls and other objects so that the air can circulate.

NOTE Place the cooler as shown (fig. 1, page 7). If you operate the cooler in a different orientation it can be damaged.

NOTICE! Danger from excessively low temperature!Ensure that the only those objects are placed in the cooler that are intended to be cooled at the selected temperature.

CFF-45--O-EN-AUS.book Seite 17 Montag, 25. Juni 2018 12:42 12

Page 18: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

Operation CFF45

18

A

I

ILatching the cooler lid

➤ Close the lid.

➤ Press the latch (fig. 2 1, page 9) down, until it latches in place audibly.

I

NOTICE! Danger of damage!Removing the basket with the lid open may scratch the lid and deform the basket. We recommend to remove the lid before removing the bas-ket.

NOTE – Displayed temperatureThe temperature displayed is that of the large interior compartment (fig. 9 1, page 18).

NOTE When operating from a battery, the display switches off automatically if the battery voltage is low. The LED “P” flashes orange.

NOTE When latching the lid, ensure that both latch side pins are fully engaged to ensure a good lid seal. One latch may engage slightly before the other.

➤ If the lid is not closed equally at both sides, press until a second click is heard.

1. 2.

9

CFF-45--O-EN-AUS.book Seite 18 Montag, 25. Juni 2018 12:42 12

Page 19: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

CFF45 Operation

19

7.6 Setting the temperature

➤ Press the “SET” button (fig. 3 4, page 10) once.

➤ Use the “UP +” (fig. 3 7, page 10) and “DOWN –” (fig. 3 6, page 10) buttons to select the cooling temperature.

✓ The cooling temperature appears in the display for a few seconds. The display flashes several times and then the current temperature is displayed again.

7.7 Setting the display brightness

The display brightness can be dimmed for low ambient light conditions. To set the dimming level of the display proceed as follows:

➤ Switch on the cooler.

➤ Press the “SET” button (fig. 3 4, page 10) four times.

➤ Use the “UP +” (fig. 3 7, page 10) or “DOWN –” (fig. 3 6, page 10) buttons to set the brightness of the display.

✓ Display will be as follows:d0 (default), d1 (medium), d2 (dark)

✓ The display shows the set mode for several seconds. The display flashes twice before it returns to the current temperature.

I

7.8 Switching off the cooler

➤ Empty the cooler.

➤ Switch the cooler off.

➤ Pull out the connection cable.

If you do not want to use the cooler for a longer period of time:

➤ Leave the lid slightly open. This prevents odour build-up.

NOTE • The factory setting of brightness of the display is d0 (default). • If a fault occurs, the brightness automatically reverts to brightness d0

(default). After troubleshooting the set brightness is reactivated.

CFF-45--O-EN-AUS.book Seite 19 Montag, 25. Juni 2018 12:42 12

Page 20: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

Operation CFF45

20

7.9 Defrosting the cooler

Humidity can form frost in the interior of the cooling device or on the evaporator. This reduces the cooling capacity. Defrost the device in good time to avoid this.

ATo defrost the cooler, proceed as follows:

➤ Take out the contents of the cooler.

➤ If necessary, place them in another cooling device to keep them cool.

➤ Switch off the device.

➤ Leave the lid open.

➤ Wipe off the defrosted water.

7.10 Replacing the AC fuse

D➤ Disconnect the power supply to the device.

➤ Remove the connection cable.

➤ Pry out the fuse insert (fig. 4 2, page 11) with a screwdriver.

➤ Replace the defective glass fuse with a new one that has the same type and rating (4 A, 250 V).

➤ Press the fuse insert back into the housing.

➤ Reconnect the power supply to the device.

7.11 Replacing the device DC Fuse

➤ Disconnect the power supply to the device.

➤ Remove the rubber cover (fig. 4, page 11) to access the fuse.

➤ Remove the fuse.

NOTICE! Danger of damage!Never use hard or pointed tools to remove ice or to loosen objects which have frozen in place.

DANGER! Danger of electrocution!Disconnect the power supply and the connection cable before you replace the device fuse.

CFF-45--O-EN-AUS.book Seite 20 Montag, 25. Juni 2018 12:42 12

Page 21: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

CFF45 Operation

21

➤ Replace the defective fuse with a new fuse of the same type (Automotive Standard blade fuse, 10 A).

➤ Re-fit the rubber cover.

➤ Reconnect the power supply to the device.

7.12 Replacing the DC plug fuse

➤ Unscrew the contact pin housing (3) from the plug (1).

➤ Replace the defective fuse (2) with a new fuse of the same type and rating (3AG, Fast Acting, 10 A).

➤ Re-assemble the plug in reverse order.

7.13 Replacing the light PCB

1 2 30

3.

2.

1.

a

CFF-45--O-EN-AUS.book Seite 21 Montag, 25. Juni 2018 12:42 12

Page 22: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

Cleaning and maintenance CFF45

22

➤ Disconnect the power supply to the device.

➤ Pry out the transparent cover with a screwdriver (1).

➤ Unscrew the PCB mounting screws (2).

➤ Pull out the plug from the PCB (3).

➤ Replace the defective light PCB with a new one.

➤ Fit new PCB using reverse of removal instructions.

➤ Press the transparent cover back into the housing.

➤ Reconnect the power supply to the device.

8 Cleaning and maintenance

!

A

➤ Occasionally clean the device interior and exterior with a damp cloth.

➤ Make sure that the air inlet and outlet vents on the device are free of any dust and dirt, so that heat can be released and the device is not damaged.

WARNING! Always disconnect the device from the power supply before you clean and service it.

NOTICE! Risk of damage• Never clean the cooler under running water or in dish water.• Do not use abrasive cleaning agents or hard objects during cleaning

as these can damage the cooler.

CFF-45--O-EN-AUS.book Seite 22 Montag, 25. Juni 2018 12:42 12

Page 23: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

CFF45 Troubleshooting

23

9 Troubleshooting

Fault Possible cause Suggested remedy

Device does not function, LED does not glow.

No voltage was detected in the DC power outlet.

In most vehicles the ignition must be turned on before power will be supplied to the DC power outlet.

No voltage present in the AC power outlet.

Try using another plug outlet.

One of the device fuses is defective.

Replace the defective device fuse, see chapter “Replacing the AC fuse” on page 20 or chapter “Replacing the device DC Fuse” on page 20.

The integrated mains adapter is defective.

This can only be repaired by an authorised repair centre.

The device does not cool (plug is inserted, “POWER” LED is lit).

Defective compressor. This can only be repaired by an authorised repair centre.

The device does not cool (plug is inserted, “POWER” LED flashes orange, display is switched off).

Battery monitor is set too high.

Select a lower battery monitor setting.

Battery voltage is too low.

Test the battery and charge it as needed.

When operating from the DC outlet:The ignition is on and the device is not working and the LED is not lit.

The DC outlet is dirty. This results in a poor electrical contact.

If the plug of your cooler becomes very warm in the DC outlet, either the DC outlet must be cleaned or the plug has not been assembled correctly.

The fuse of the DC plug has blown.

Replace the fuse in the DC plug, see chapter “Replacing the DC plug fuse” on page 21.

The device DC fuse has blown.

Replace the defective fuse, see chapter “Replacing the device DC Fuse” on page 20.

The vehicle fuse has blown.

Replace the vehicle’s DC outlet fuse. Please refer to your vehicle’s operating manual.

CFF-45--O-EN-AUS.book Seite 23 Montag, 25. Juni 2018 12:42 12

Page 24: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

Troubleshooting CFF45

24

9.1 The lid has been forced past the built-in stop

➤ Support the lid with one hand (A).

➤ Hold the latch down with the other hand (B).

!

A➤ Close the lid as far as possible without pinching your thumb, while still holding

the latch down, to keep it from breaking.

✓ The lid should now be approximately at angle (fig. b, page 24).

➤ Remove the hand from the latch (B), and continue closing the lid all the way.

The display shows an error message (e.g. “Err1”) and the appliance does not cool.

The appliance has switched off due to an internal fault.

This can only be repaired by an authorised repair centre.

CAUTION! Health hazard!Beware pinching your thumb while closing the lid.

NOTICE! Danger of damage!Failure to observe this instruction can cause the lid to break off.

Fault Possible cause Suggested remedy

A

B

b

CFF-45--O-EN-AUS.book Seite 24 Montag, 25. Juni 2018 12:42 12

Page 25: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

CFF45 Guarantee

25

I

10 GuaranteeThe statutory warranty period applies. If the product is defective, please contact the manufacturer's branch in your country (see the back of the instruction manual for the addresses) or your retailer.

For repair and guarantee processing, please include the following documents when you send in the device:

• A copy of the receipt with purchasing date

• A reason for the claim or description of the fault

11 Disposal➤ Place the packaging material in the appropriate recycling waste bins wherever

possible.

MIf you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.

12 Technical data

NOTE The hinges may release from the correct position during the final closing action. Reposition the lid as follows:

➤ Operate the latches on both sides of the lid simultaneously.

➤ Lift and reposition the lid.

CFF45

Ref. no.: 9600010944

Connection voltage 12/24 Vg and 100 – 240 Vw

Rated current: 12 Vg: 5.2 A24 Vg: 2.6 A

100 Vw: 0.6 A240 Vw: 0.4 A

Cooling capacity: 10 °C to –18 °C (+50 °F to 0 °F)

CFF-45--O-EN-AUS.book Seite 25 Montag, 25. Juni 2018 12:42 12

Page 26: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

EN

Technical data CFF45

26

ITest/certificates:

The coolant circuit contains R134a.

Contains fluorinated greenhouse gases

Hermetically sealed equipment

Category: 1

Energy efficiency class: A+

Energy consumption: 90 kWh/annum

Gross volume: 45 l

Storage volume: 43.5 l

Climate class: N, T

Ambient temperature +16 °C to +43 °C

Refrigerant quantity: 50 g

CO2 equivalent: 0.072 t

Global warming potential (GWP): 1430

Dimensions (W x H x D) in mm (including handles):(W x H x D) in mm (with handles removed):

715 x 475 x 398590 x 475 x 398

Weight: 18.6 kg

NOTE If the ambient temperature is above +32 °C (+90 °F), the minimum temperature cannot be attained.

CFF-45--O-EN-AUS.book Seite 26 Montag, 25. Juni 2018 12:42 12

Page 27: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

CFF-45--O-EN-AUS.book Seite 27 Montag, 25. Juni 2018 12:42 12

Page 28: CFF-45--O-EN-AUS.book Seite 1 Montag, 25. Juni 2018 12:42 12 … · 2018. 9. 20. · CFF-45--O-EN-AUS.book Seite 11 Montag, 25. Juni 2018 12:42 12. EN Operation CFF45 12 7Operation

AUSTRIADometic Austria GmbHNeudorferstraße 108A-2353 Guntramsdorf +43 2236 908070 +43 2236 90807060Mail: [email protected]

BENELUXDometic Branch Office BelgiumLourdesstraat 84B-8940 Geluwe +32 2 3598040 +32 2 3598050Mail: [email protected]

BRAZILDometic DO Brasil LTDAAvenida Paulista 1754, conj. 111SP 01310-920 Sao Paulo +55 11 3251 3352 +55 11 3251 3362Mail: [email protected]

DENMARKDometic Denmark A/SNordensvej 15, TaulovDK-7000 Fredericia +45 75585966 +45 75586307Mail: [email protected]

FINLANDDometic Finland OYMestarintie 4FIN-01730 Vantaa +358 20 7413220 +358 9 7593700Mail: [email protected]

FRANCEDometic SASZA du Pré de la Dame JeanneB.P. 5F-60128 Plailly +33 3 44633525 +33 3 44633518Mail : [email protected]

GERMANYDometic WAECO International GmbHHollefeldstraße 63 · D-48282 Emsdetten +49 (0) 2572 879-0 +49 (0) 2572 879-300Mail: [email protected]

HONG KONGDometic Group Asia PacificSuites 2207-11 · 22/F · Tower 1The Gateway · 25 Canton Road,Tsim Sha Tsui · Kowloon +852 2 4611386 +852 2 4665553Mail: [email protected]

HUNGARYDometic Zrt. Sales OfficeKerékgyártó u. 5.H-1147 Budapest +36 1 468 4400 +36 1 468 4401Mail: [email protected]

ITALYDometic Italy S.r.l.Via Virgilio, 3I-47122 Forlì (FC) +39 0543 754901 +39 0543 754983Mail: [email protected]

JAPANDometic KKMaekawa-Shibaura, Bldg. 22-13-9 Shibaura Minato-kuTokyo 108-0023 +81 3 5445 3333 +81 3 5445 3339Mail: [email protected]

MEXICODometic Mx, S. de R. L. de C. V.Circuito Médicos No. 6 Local 1Colonia Ciudad SatéliteCP 53100 Naucalpan de JuárezEstado de México +52 55 5374 4108 +52 55 5393 4683Mail: [email protected]

NETHERLANDSDometic Benelux B.V.Ecustraat 3NL-4879 NP Etten-Leur +31 76 5029000 +31 76 5029019Mail: [email protected]

NEW ZEALANDDometic New Zealand Ltd.PO Box 12011PenroseAuckland 1642 +64 9 622 1490 +64 9 622 1573Mail: [email protected]

NORWAYDometic Norway ASØsterøyveien 46N-3232 Sandefjord +47 33428450 +47 33428459Mail: [email protected]

POLANDDometic Poland Sp. z o.o.Ul. Puławska 435APL-02-801 Warszawa +48 22 414 3200 +48 22 414 3201Mail: [email protected]

PORTUGALDometic Spain, S.L.Branch Office em PortugalRot. de São Gonçalo nº 1 – Esc. 122775-399 Carcavelos +351 219 244 173 +351 219 243 206Mail: [email protected]

RUSSIADometic RUS LLCKomsomolskaya square 6-1RU-107140 Moscow +7 495 780 79 39 +7 495 916 56 53Mail: [email protected]

SINGAPOREDometic Pte Ltd18 Boon Lay Way06–141 Trade Hub 21Singapore 609966 +65 6795 3177 +65 6862 6620Mail: [email protected]

SLOVAKIADometic Slovakia s.r.o.Sales Office BratislavaNádražná 34/A900 28 Ivánka pri Dunaji/ +421 2 45 529 680Mail: [email protected]

SOUTH AFRICADometic (Pty) Ltd.Regional OfficeSouth Africa & Sub-Saharan Africa2 Avalon RoadWest Lake View Ext 11Modderfontein 1645Johannesburg +27 87 3530380Mail: [email protected]

SPAINDometic Spain S.L.Avda. Sierra del Guadarrama, 16E-28691 Villanueva de la CañadaMadrid +34 902 111 042 +34 900 100 245Mail: [email protected]

SWEDENDometic Scandinavia ABGustaf Melins gata 7SE-42131 Västra Frölunda +46 31 7341100 +46 31 7341101Mail: [email protected]

SWITZERLANDDometic Switzerland AGRiedackerstrasse 7aCH-8153 Rümlang +41 44 8187171 +41 44 8187191Mail: [email protected]

UNITED ARAB EMIRATESDometic Middle East FZCOP. O. Box 17860S-D 6, Jebel Ali FreezoneDubai +971 4 883 3858 +971 4 883 3868Mail: [email protected]

UNITED KINGDOMDometic UK Ltd.Dometic House, The BreweryBlandford St. MaryDorset DT11 9LS +44 344 626 0133 +44 344 626 0143Mail: [email protected]

USADometic RV Division1120 North Main StreetElkhart, IN 46515 +1 574-264-2131

AUSTRALIADometic Australia Pty. Ltd.1 John Duncan Court · Varsity Lakes QLD 4227 1800 212121 · +61 7 55076001Mail: [email protected]

dometic.com

4445

1025

6206

/201

8

CFF-45--O-EN-AUS.book Seite 28 Montag, 25. Juni 2018 12:42 12