MD-200, TA-200, RA-200 & MR-200
Mando a distancia, Termostatos deambiente y Mdulo repetidor para cuadrosde control electrnicos CCEInstrucciones de Instalacin,Montaje y Funcionamiento para elINSTALADOR
ES
FR
DE
IT
PT
GB
Fernsteuerung, Raumthermostate undVerstrkermodul fr elektronischeSchalttafeln CCEInstallation-, Montage-und Betriebsanleitung fr denINSTALLATEUR
Remote Control, Room Thermostats andRepeater Module for CCE ElectronicControl PanelsInstallation, Assembly, andOperating Instructions for theINSTALLER
Comando a distanza, Termostati ambientee Modulo ripetitore per quadro comandielettronico CCEIstruzioni dInstallazione,Montaggio e Funzionamento perlINSTALLATORE
Comando distncia, Termostatos deambiente e Mdulo amplificador paraquadros de controlo electrnicos CCEInstrues de Instalao,Montagem e Funcionamento para oINSTALADOR
Tlcommande, Thermostats dambianceet Module rptiteur pour tableaux decontrle lectroniques CCEInstructions dInstallation,de Montage et de Fonctionnement pourlINSTALLATEUR
2
1/ 1 Bis
2
Tapa/Mdulo RadioCover/Radio Module
Couvercle/Module radio
Abdeckung/FunkmodulCoperchio/Moulo radioTampa/Mdulo Rdio
TA Convencional / Conventional RTTA Conventionnel / Herkmmlicher RaumthermostatTA Convenzionale /TA Convencional
TA 200 / MD 200
4 Mando GT / Steuerung GTGT Control / Comando GT
Commande GT / Comando GT
3
2
1
3
Tapa / Cover / CouvercleAbdeckung / Coperchio / Tampa
6 7
8 9 10
Modulo Radio / Radio Module / Module RadioFunkmodul / Modulo Radio / Modulo Rdio
5 Mando GTI-GTA / Steuerung GTI-GTAGTI-GTA Control / Comando GTI-GTACommande GTI-GTA / Comando GTI-GTA
3 4
4
11 13
5
Tensin / Power / TensinSpannung / Tensione / Corrente
Anomala / FaultAnomale / StrungAnomala / Anomala
Anomala presinPressure faultAnomale pressinStrung druckAnomala della pressioneAnomala presso
Anomala Tcnica / Technical faultAnomale Technique / Tecnische strungAnomala Tecnica / Anomala Tcnica
Mando caldera / Boiler controlCommande chaudire / Steuerung KesselComando caldaia / Comando caldeira
Selector de servicios / Service selector / Slecteur de servicesBetriebswahlschalter / Selettore modo di funzionamento / Selector de servios
Aumento / Increase / Augmentation / Erhhung / Aumento / Aumento
Disminucin / Decrease / Diminution / Verminderung / Disminuzione / Disminuo
A.C.S. / D.H.W. / E.C.S. / Heiwasser / A.C.S. / A.Q.S
Calefaccin / Heating / Chauffage / Heinzung / Riscaldamento / Aquecimento Central
Presin / Pressure / Pression / Druck / Pressione / Presso
5
12
Calef. Confort + A.C.S. / Heat. Comfort + DHWChauf. Confort + E.C.S. / Heizung komfortbetrieb +HeiwasserRiscald. Confort + A.C.S. / Aquec Conforto + A.Q.S.
Calef. economa + A.C.S. / Heating economy + DHWChauf. conomie + E.C.S. / Heizung absenkbetrieb + HeiwasserRiscald. economia + A.C.S. / Aquec. economia + A.Q.S.
Solo calef. economa / Only heating economySeulement chauf. economie / Nur Heizung absenkbetriebSolo riscald. economia / S aquec. economia
Temperatura ambiente / Room temperatureTemprature ambiante / RaumteperaturTemperatura ambiente / Temperatura ambiente
Cursor diario / Day cursorCurseur jour / TagesanzeigerCursore dei giorni / Cursor dirio
Escala y cursor horario / Scale and Time cursorchelle et curseur horaireSkala und StundenanzeigerScala e cursore delle ore / Escala e cursor horrio
Programacin / ProgrammingProgrammation / ProgrammierungProgrammazione / Programao
Cambio hora / Set timeChangement dheure / Uhrzeit-WechselCambio di ora / Alterao hora
Cambio da / Set dayChangement de jour / Tages-WechselCambio di giorno / Alterao dia
Horas - minutos/ Hours - minutesHeures - minutes/ Stunden-minutenOre-minuti / Horas - minutos
Escala / Scalechelle / SkalaScala / Escala
GB
Technical dataSupply Voltage: MD-200 and TA-200: 15 Vdc RA-200: 3 LR AA 06 alkaline batteries MR-200: 230V 50HzStorage temperature: from -20 C to 70 COperational temperature: from 0 C to 50 C(from 0 C to 40 C for MR-200)
DeliveryIn a single package which contains: MD-200 with wall bracket, 2 rawlplugs, screws
and terminal strip. TA-200 with wall bracket, 2 rawlplugs, screws
and terminal strip. RA-200 with wall bracket, 3 LR AA 06
batteries, stand, 2 rawlplugs and screws. MR-200 with wall bracket, 2 rawlplugs and
screws.
InstallationThe contents of these Instructions refer to theeffect that handling the component in questioncan have on the behavior of the installation. Itis recommended that the written instructionsbe followed and applied when the component isbeing manipulated.
TA-200 Room Thermostat (Fig. 1)a) Disconnect the boiler from the electrical
supply (1).b) Connect the two wires (telephone cable can
be used) to the 2-lug terminal strip providedas shown in (Fig. 2). It is advisable that thelength of the cable does not exceed 30m.
c) Remove the TA-200 from its wall bracket(Fig. 3) by carefully pressing the lower partof the closing tag with a screwdriver, throughthe rectangular hole for this purpose. Ifsurface cable is used, proceed to:1 Break the thin wall (1) to enable passing
the cable.
2 Fix the bracket to the wall, at a height of1.5m from floor level, using the rawlplugsand screws supplied, in such a way thatthe closing tag is on the lower part.
3 Pass the cable through the hole brokenin the thin wall (1) and wire it to theterminals provided on the bracket.
d) If embedded cable is used, proceed to:1 Fix the bracket to the wall as indicated in
2 above.2 Pass the cable through the window (2).
(Fig. 3).3 Wire the cable to the terminals provided.
e) Remove the cover from the TA-200.f) Couple the body of the TA-200 thermostat to
the wall bracket, hanging it from the upperpart and pressing the lower part until it isretained.
g) Withdraw the Control from the boiler (Figs. 4or 5) and couple it to the body of thethermostat. (Fig. 6).
10
h) Place the cover of the TA-200 thermostat inthe seat left in the control panel when theboiler control was removed.
i) Restore the power supply to the boiler.
MD-200 Remote ControlProceed as indicated for the TA-200 in theprevious section, replacing references toTA-200 with MD-200 (Fig. 7).
RA-200 Room Thermostat andMR-200 Repeater ModuleMR-200 Room thermostatTo install the RA-200 (Fig. 1b) proceed to:a) Disconnect the boiler from the electrical
supply (1) and Withdraw the RA-200 from itswall bracket (Fig. 3) as described in operationc) above for the TA-200 thermostat, andremove the plastic strip (3) (Fig. 8) from thebattery compartment.
b) If the wall bracket is used instead of thestand (4) (Fig. 9), fix it to the wall asdescribed in operation 2 c) for the TA-200thermostat.
c) Repeat operations f), g) and h) indicated forthe TA-200, replacing the references toTA-200 cover and wall bracket with radiotransmitter module and wall bracket orstand, respectively and Restore the powersupply to the boiler
Note: The range of the RA-200 varies inside abuilding (according to properties of the walls,etc.). To increase the operating range betweenboiler and thermostat, up to two MR-200Repeater Modules can be installed, or make acombined installation with an MD-200 RemoteControl as is described later.d) Once the RA-200 is installed, it is advisable
to check the quality of communication, aswill be described later in the paragraphsChecking the Quality of Communications ofthe RA-200 and Radio CommunicationsTest.
MR-200 Repeater Module(s)Before installing the MR-200 Repeater Module(Fig. 10) your radio module must be configuredwith the green LED (Fig. 11) to receive ordersfrom a specific RA-200. To do this proceed to: Remove the batteries from the RA-200
thermostat. Remove the radio module with the green LED
from the MR-200 and, with the selector (5)(Fig. 11), select the type of repeater. For asingle repeater select type A; if two areinstalled, select A in one and B in theother.
Remove the boiler control (Fig. 5 or 6) fromthe RA-200 and place the radio module withthe green LED, taken from the MR-200, onthe RA-200 thermostat.
Remove the radio module with the green LEDfrom the MR-200 placed on the RA-200.Replace the batteries and boiler control inthe RA-200 thermostat. The RA-200 code istransferred to the MR-200 radio module withthe green LED.
To install the MR-200 repeater module(s), nowconfigured, proceed to: Fix the wall bracket(s) to the wall as described
previously in b), c) and d) for the TA-200thermostat, replacing reference to TA-200with MR-200. Remember that the powersupply to the MR-200 Repeater Module is230V 50Hz and cable of 0.5mm crosssection, at minimum, should be used.
Place the radio module(s) on the MR-200Repeater Module(s).
Combined Installation of MD-200 RemoteControl and RA-200 Room ThermostatIn those cases where some radio-electrical obstacle(washing-machine, concrete floor slab, metal doors,etc.) impedes correct connection betweenthermostat and boiler, and there is no need forrepeaters once past the obstacle, a combinedtwo-cable / radio installation can be used, whichpermits separating the radio module from the boilerby up to 30m. In this case proceed to:a) Install the MD-200 as described in previous
sections a) to e) for the TA-200, replacingreferences to TA-200 with MD-200.
b) Install the RA-200 on its bracket as describedin previous sections a) and b) for theRA-200 thermostat.
c) Place the cover of the MD-200 on the controlpanel, the boiler control on the RA-200 andthe RA