Freimaßtoleranzen
DIN 7168
fein mittel grob
Oberfläche
DIN 1302
Reihe 5
Urheberschutz nach DIN 34Jede Vervielfältigung, Nachbau oder
Weitergabe an Dritte ist untersagtoder bedarf unserer schriftlichen
Genehmigung.
Format DIN A0
Datum Name
Gez.
Gepr.
Ing. Viehböck
Dateiname:
a
b
c
d
e
f
g
Index Änderung Datum Name
Fläche Gewicht
Maßstab
WerkstoffOberfläche
24.06.2016
Liftanlage 16-0244.dft
0,000 kg
A
B
C
D
E
F
8 7 6 5 4 3 2 1
G
H
11 10 912
I
J
K
L
B
C
D
E
F
G
H
I
J
K
L
13141516
8 7 6 5 4 3 2 111 10 91213141516
servelift gmbh
A-4161 Ulrichsberg Tel. +43(0)7288/27120 Kreuzlandl 3 Fax.+43(0)7288/27120-20 www.servelift.com [email protected]
AA
section A-A
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass10 mm
laminatedglass
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
1400
1100
1580
1515
1550
1600
call station:- key switch- call button
call station:- key switch- call button
call station:- key switch- call button
emergency wheel(demountable)
100
1500
4250
I agree with the execution as shown at the drawing:(free for production)
date, signature: ............................................................................
Electrical requirements for installation site: Mandatory requirements for installation site according to VdTÜV leaflet Elevators 103 or EN 81-41:2004:
- Socket outlet 230V /50Hz protected minimum. B13 for maintenance work near to the lowest station.
- Error current - sensitive to universal current– protection (FI) with minimum >= 30mA release current.
- Main switch with 2 poles, minimum 25A to disconnect all poles of the main power supply (supply line). This switch must be lockable and is exclusively installed fort he power supply of the elevator. The power supply for lighting and socket outlet must remain life for maintenance work.
- Overvoltage protection device type „C“ to protect against external overvoltage from the supply line. (to be installed in the house terminal resp. the nearest sub-terminal.
- Grounding for potential equalisation minimum 4mm². - Maximum grounding resistance: 3 ohm - Lightning protection is necessary for outdoor installation of the elevator.. - empty tube minimum 80 mm diameter from electrical cabinet to lift guide
- Only for installations with isolated neutral point ( IT-nets): Cut-off transformer
minimum approx. 4000VA. Additional requirments:
- For externally mounted calling stations : empty tube minimum 25 mm diameter (from electrical cabinet to first door, from 1st door to 2nd door, … and so on … - No grounding necessary. (low voltage). - For optional emergency telephone a connection cable with min. 4x0,25 mm² is
necessary to the position of the electrical switch box!
Electrical characteristics: Nominal voltage: 230V / 50Hz Nominal current: 8,5 A Max. current consumption: 16,4 A shortterm Nominal power (Frequency Converter): 2,2 kW Cross section: Min. 3x2,5 mm² Pre-fuse: Min. C25 Control voltage: 24Vdc – short curcuit proof
servelift V10: outdoor- platformsize 1100x1400 mm- max. load capacity 385 kg- smooth start and stop- 3 stops, 3 call stations (key switch "standard", call button => no key switch on lift panel) - lower station: - manual revolving door DIN L - inner door width approx. 995x2074 mm - selfclosing - middle station: - manual revolving door DIN L - inner door width approx. 973,5x2074 mm - selfclosing - upper station: - manual revolving door DIN R - inner dooir width approx. 995x2074 mm- selfdialing emergency telephone "AMIGO II"- battery back-up for emergency lowering in case of power failure- full glass roof- electrical switch box RAL 7035 with heating- thermostate regulated shaft ventilation- all visible surfaces powdercoated RAL 7024
by Hissipörssi OY:- transport- installation- costs for final inspection
max. foundation load in the area of thelift guide (230x706mm) approx. 10,6kNunder suspension of a force of impactof 5 (fully loaded into safety catch) approx. 53 kN
max. foundation load causedby shaft weight approx. 13 kN
max. tensile loadingsapprox. 3,5-4,5 kNat each fixing point!
120
5730
1394
4121
updated according to e-mailfrom 27th of June 2016
30.6.2016 KV
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated
glass
3000
1460
updated according to e-mailfrom 21st of July 2016
2.8.2016 KV
10 mmlaminated
glass
10 mmlaminated
glass
10 mmlaminated glass
10 mmlaminated glass
10 mmlaminated glass
10 mmlaminated glass
10 mmlaminated
glass
updated according to e-mailfrom 3rd of August 2016 3.8.2016 KV
2228
16
full glass roof